Polyimide films are currently of great interest for the development of flexible electronics and sensors. In order to ensure a proper integration with other materials and PI itself, some sort of surface modification is required. In this work, microwave oxygen plasma, reactive ion etching oxygen plasma, combination of KOH and HCl solutions, and polyethylenimine solution were used as surface treatments of PI films. Treatments were compared to find the best method to promote the adhesion between two polyimide films. The first selection of the treatment conditions for each method was based on changes in the contact angle with deionized water. Afterward, further qualitative (scratch test) and a quantitative adhesion assessment (peel test) were performed. Both scratch test and peel strength indicated that oxygen plasma treatment using reactive ion etching equipment is the most promising approach for promoting the adhesion between polyimide films.
1 August 2016 in Sensors and Actuators A: Physical
Electrocorticography (ECoG) electrode arrays for epidural implantation allow establishing neural interfaces, which promote investigation of complex distributed brain functions and development of neuroprosthetic systems, while having reduced invasiveness in comparison to intracortical or subdural electrode placement. In this work, we present the design, fabrication, and both in-vitro and in-vivo evaluation of a flexible ECoG array with 202 closely spaced electrodes of 560 μm diameter, each coated with the polymer poly(3,4-ethylenedioxythiophene): polystyrene sulfonate (PEDOT: PSS) for chronic recording in two visual cortical areas V1 and V4 of macaque monkeys. The specific layout of the array provides a close fit to the curved surface of the brain. We confirm its chronic recording functionality in-vivo by estimating visual receptive fields for the individual electrodes.
1 November 2011 in Journal of Vacuum Science & Technology B
For the chronic application of neural prostheses long-term stable microelectrodes for electrical stimulation are essential. In recent years many developments were done to investigate different appropriate materials for these electrodes. One of these materials is the electrical conductive polymer PEDOT, which has low impedance and high charge injection capacity. However, the long-term stability of this polymer is still unclear. Thus this paper reports on the in-vitro evaluation of the long-term stability of PEDOT coated gold microelectrodes. For this purpose a flexible electrode array is used, which consists of circular gold microelectrodes. The electrodes were coated simultaneously with the polymer PEDOT:PSS using a galvanostatic electropolymerization process. After coating the array is additionally sterilized using a steam sterilization process, which is necessary prior to the implantation of such an electrode array. The long-term measurements were performed in phosphate-buffered saline solution at the constant body temperature of 37°C. For the in-vitro electrical stimulation a single channel bipolar current stimulator is used. The stimulation protocol consists of a bipolar current amplitude of 5 mA, a pulse duration of 100 μs per phase, an interphase gap of 50 μs and a frequency of 1 kHz. The electrical stimulation is performed continuously. The condition of the PEDOT coated electrodes is monitored in between with electrical impedance spectroscopy measurements. The results of this study demonstrate that the PEDOT coated electrodes are stable for at least 7 weeks of continuous stimulation, which corresponds in total to more than 4.2 billion bipolar current pulses. Also the unstimulated electrodes show currently no degradation after the time period of more than 10 months. These current results indicate an appropriate long-term stability of this electrode coating for chronic recording and electrical stimulation.