Minerva Gabriela Vargas Gleason

Mrs. Minerva Gabriela Vargas Gleason

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2021 in Polymers
Verified
Journal Article
Open access
PDF file
MCMarco Cen-Puc
Marco Cen-Puc
ASAndreas Schander
Andreas Schander
MGMinerva Gabriela Vargas Gleason
Minerva Gabriela Vargas Gleason
WLWalter Lang
Walter Lang
Polyimide films are currently of great interest for the development of flexible electronics and sensors. In order to ensure a proper integration with other materials and PI itself, some sort of surface modification is required. In this work, microwave oxygen plasma, reactive ion etching oxygen plasma, combination of KOH and HCl solutions, and polyethylenimine solution were used as surface treatments of PI films. Treatments were compared to find the best method to promote the adhesion between two polyimide films. The first selection of the treatment conditions for each method was based on changes in the contact angle with deionized water. Afterward, further qualitative (scratch test) and a quantitative adhesion assessment (peel test) were performed. Both scratch test and peel strength indicated that oxygen plasma treatment using reactive ion etching equipment is the most promising approach for promoting the adhesion between polyimide films.

15 July 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MGMinerva Gabriela Vargas Gleason
Minerva Gabriela Vargas Gleason
RJReiner Jedermann
Reiner Jedermann
MDMohamed Adli Dimassi
Mohamed Adli Dimassi
WLWalter Lang
Walter Lang
This paper presents a novel wireless sensor system that can be embedded in both glass and carbon fiber composites allowing for the first time to wirelessly measure pressure and temperature throughout the laminate during infusion, giving an insight into the process behaviour. The obtained data can be used for modelling the resin flow inside the composite, which is required for simulation and for speeding up the design of new parts. We suggest a system, which uses wireless data transmission that does not hurt the vacuum seal, even for sensors deeply embedded between conductive carbon fibers. The current sensor system gives an accurate pressure reading (mbar resolution) that provides information about the pressure gradient in the whole laminate. For carbon fibers, the sensors are soldered on a self-made, flexible, 10 μ-thick polyimide cable, which is resistant to high temperatures. This makes the system minimally invasive since only a 2mm × 2.5mm system remains inside the laminate.