Magnetic compensation coils are often used to improve the effectiveness of a magnetically shielded room (MSR), but a distortion of the field is caused by the shielding layer consisting of high-permeability material, which leads to a reduction in compensation capacity. To solve this problem, a new method is presented in this article based on a target-field method, an image method, and particle swarm optimization. By this way, a magnetic compensation system composed of biplanar coils is designed and fabricated to compensate the background field for a wearable magnetoencephalography device inside the MSR, and the coupling effect between the magnetic shielding material and the compensation field is effectively avoided. Experimental data show that these compensation coils produce uniform fields and field gradients with the inhomogeneity of less than 3.8%, consistent with the simulation results. In addition, this system realizes a real-time compensation to the residual field and field gradient in the MSR.
To achieve the nearly zero-field environment, demagnetization is an indispensable step for magnetic shields composed of high-permeability material, which adjusts the magnetization of the material to establish magnetic equilibrium with the environmental field and improve the shielding performance. The ideal demagnetization can make the high-permeability material on the anhysteretic magnetization curve to have a higher permeability than on the initial magnetization curve. However, inappropriate parameters of degaussing field cause the magnetization state to deviate from the anhysteretic magnetization curve. Therefore, this article proposes a new assessment criterion to analyze and evaluate the parameters of degaussing field based on the difference between the final magnetization state after demagnetization and theoretical anhysteretic state of the shielding material. By this way, the magnetization states after demagnetizations with different initial amplitude, frequency, period number and envelope attenuation function are calculated based on the dynamic Jiles–Atherton (J–A) model, and their magnetization curves under these demagnetization conditions are also measured and compared, respectively. The lower frequency, appropriate amplitude, sufficient period number and logarithmic envelope attenuation function can make the magnetization state after demagnetization closer to the ideal value, which is also consistent with the static magnetic-shielding performance of a booth-type magnetically shielded room (MSR) under different demagnetization condition.
19 September 2023 in IEEE Transactions on Industrial Electronics
Biomagnetic field measurements necessitate magnetic shields of high performance, particularly for quasi-static and low-frequency fields. These largely rely on the magnetic properties of the shielding material. Magnetic shaking can enhance the material's permeability by reducing hysteresis loss, though this method introduces field interference into the shielding device, complicating the magnetic environment. In this study, an attenuation coefficient is introduced into the Jiles–Atherton model to quantify the suppression effect of magnetic shaking on hysteresis loss, based on measurements of magnetic properties under the shaking fields. To improve shielding performance while minimizing additional interference, the frequency of magnetic shaking is increased and applied only to the outermost layer of the shielding device. Through testing and fitting results, the impact of various magnetic shaking conditions on a cubic magnetic shielding device is examined. By applying a shaking field of 200 Hz solely to the outermost layer, the shielding factor (@0.01 Hz) of a three-layer device increases by 77.4% without additional magnetic noise. This method is also applied to a magnetically shielded room, enhancing its shielding factors by more than two times.
5 April 2023 in Journal of Physics D: Applied Physics
In recent decades, magnetic shields have provided basic experimental environments for the measurements of extremely weak magnetic fields represented by the biological magnetic signal. Excellent shielding performances, including the low residual field and high shielding factor (SF), are necessary to ensure the quality of these weak magnetic signals and avoid the interference of external magnetic fields. The magnetic shielding performance of the same device can be affected by different degaussing and test conditions, which remains to be systematically studied. In this paper, experiments with variable magnetization conditions, including different degaussing orders, test fields and environmental fields, are established in a nearly zero-field space to simulate the different situations during measurement. The residual field and SF of the cubic shielding device are tested in these cases. Meanwhile, these shielding performances are analyzed from the perspective of the magnetization state and calculated based on the magnetic properties which are tested and fitted by the Jiles–Atherton model. The results show the influence of these different conditions on the shielding performances of the cubic device, consistent with the numerical calculation. Under the same environmental field, the different degaussing order and test field lead to completely different residual field and shielding performance, respectively. The influence of the Earth’s magnetic field on the SF can be ignored due to its tiny equivalent bias field determined by the anhysteretic magnetization curve.
22 June 2022 in IEEE Transactions on Instrumentation and Measurement
Generally, a permalloy sheet is applied as the major shielding material for weakening the environmental magnetic field interference in a field of high-precision measurement. The demagnetization for a permalloy sheet determines its shielding performance; therefore, an enhanced method for measuring the magnetic properties under degaussing excitation is proposed in this article. The excitation apparatus and a feedback control system are designed for regulating the $B$ curve of a permalloy sheet as the desired amplitude and waveform. Furthermore, a method for applying degaussing excitation is proposed, and the corresponding measurement approach under such magnetic conditions is investigated. Finally, the dynamic Jiles–Atherton model is combined with a finite element method (FEM) algorithm for applying the tested data to the residual magnetic field calculation of a scaled-down model. The agreement between the calculated and tested remanence distribution indicates that the proposed measurement method is reliable and applicable.
UHF (ultra high frequency) method has been widely used in PD (partial discharge) detection for its high sensitivity. The resonance, distortion, and attenuation appearing in the propagation process of UHF signals in GIS (gas insulated switchgear) will influence the real situation of PD detection. Therefore, it is necessary to investigate the effect of GIS components such as disconnectors or high voltage conductors on the propagation characteristics of PD‐induced UHF signals in various voltage classes GIS. The factors of PD signals propagation characteristics in axial and radial directions are both analysed to avoid the effect caused by placement of sensor in this paper. First, the simulation models of GIS are built based on FDTD (finite difference time domain) method. Then the propagation characteristics of PD‐induced UHF signals are studied in the GIS with different disconnector gap lengths and different high voltage conductor radii. Finally, the reliability of the simulation results is verified by compared with laboratory tests. The disconnector gap and the change of conductor radii can both result in the signals attenuation which rises highest in the direction of 180°. The lower the GIS class voltage is, the larger the attenuation of signals after passing through disconnector gap is.