This paper describes a microwave resonator incorporating microfluidic lab-on-chip sensor system capable of performing simultaneous differential measurement based sensing of liquid samples. The resonators are split-ring resonator shapes made of gold on glass substrates. Directly bonded on glass substrates are polydimethylsiloxane microchannels. Sensor system design incorporates a pair of identical resonators, one of which performs reference reading from the background. Tracking the difference of the responses of both resonators simultaneously, rather than a single one, is used to obtain a more linear and noise-free reading. The sensor system was produced with conventional fabrication techniques. It is compatible with low-cost, simple, easy to handle sensing applications. Results indicate that reliable differential measurement was possible owing to a well-matched pair of sensors with a response error as low as 0.1%. It was also demonstrated that differential measurement capability enables sensing with improved linearity. Measurements were performed with glucose solutions in the range of 3.2–16.1 mM, achieving a sensitivity of 0.16 MHz/mM.
Use of microwave resonator-based sensors is a relatively new approach for the detection of biological reagents. Sensing mechanism is based on the tracking of the resonant frequency on electromagnetic resonator. Resonant frequency depends on structure geometry and material but is also affected by secondary changes in environment. Addition of a reference resonator to suppress these effects is proposed in this work. Identical sensor structures designed at2 GHz, fabricated using low-cost processes are used in experiments to demonstrate the use of a resonator pair for sensing of glucose in solutions, yielding a sensitivity of 34.72 MHz/ (mg/mL).
This paper presents an electromagnetic actuation-based optoelectronic active catheter tracking system for magnetic resonance imaging (MRI). The system incorporates a radio frequency (RF) microelectromechanical system (MEMS) resonator array actuated by the Lorentz force induced due to the strong dc magnetic field available in MRI environment. Power transfer to the system and the actuation detection are done optically via fiber optic cables that replace conventional conductive transmission lines; thereby, enabling the tracking system to function safely under MRI. The complementary metal-oxide-semiconductor (CMOS) receiver, optically powered by a supply unit housing an on-chip silicon photovoltaic cell, detects the location of the catheter tip. The RF MEMS resonator array transmits the position data by transducing the electrical signal into a resonant mechanical vibration linearly. The optical reading of this actuation can be done by diffraction grating interferometry or laser doppler vibrometry. The fabricated resonator array is tested with the optically powered CMOS chip (0.18-μm UMC technology) in laboratory conditions. The driving electrical current supplied by the chip for resonator actuation is 25-μA rms, where the magnetic field provided by the experimental setup is 0.62 T. The resonator array is observed to be functional with real-world application by showing a frequency response of 10 dB, which will be enhanced further under the stronger magnetic field available in 3-T MRI.
Microwave resonator-based sensors offer low-cost, contactless, label-free sensing solutions in a variety of applications. Sensing is done by the observation of the shifts in resonant frequency of the sensor structure, which depends on resonator geometry, material and physical properties of the environment. It is observed that the readings can be significantly affected by changes in secondary physical parameters or sample localization on resonator. A double microwave resonator sensing system incorporating microchannels on glass substrates are proposed to address these challenges. PDMS microchannels bonded on glass substrates are mounted on split ring resonators fabricated via low-cost processes. Experiments are performed with glucose solutions of 1.4 mg/mL–3.0 mg/mL concentration range. Results confirm that the use of double resonators increase rejection of background noise, whereas microchannel use increases measurement stability. Overall measurement sensitivity is shown to be 0.92 MHz/(mg/mL). Further improvements are aimed with the bonding of microchannels directly on resonators fabricated on glass substrates.