Carlos M. C. Renedo

Mr. Carlos M. C. Renedo

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2023 in Journal of Sound and Vibration
Verified
Journal Article
Open access
CGChristian Gallegos-Calderón
Christian Gallegos-Calderón
JNJavier Naranjo-Pérez
Javier Naranjo-Pérez
CRCarlos M. C. Renedo
Carlos M. C. Renedo
Iván M. DíazIván M. Díaz
Iván M. Díaz

13 July 2023 in Actuators
Verified
Journal Article
Open access
PDF file
CRCarlos M. C. Renedo
Carlos M. C. Renedo
Iván M. DíazIván M. Díaz
Iván M. Díaz
Jaime H. García-PalaciosJaime H. García-Palacios
Jaime H. García-Palacios
CGChristian Gallegos-Calderón
Christian Gallegos-Calderón
Due to current architectural trends, contemporary public buildings are becoming open-plan spaces with much less weight and damping. Consequently, Vibration Serviceability Limit State (VSLS) due to human-induced vibrations has become an increasing concern for structural engineers, especially when designing offices, hospitals, or gymnasiums. When dealing with resonant vibrations, a slight increase in the floor-damping enables decreasing considerably the vibration level. The damping strategy studied in this work is usually known in the literature as Constrained Layer Damping (CLD) and consists of a viscoelastic layer constrained between the concrete slab and the steel beam of a lightweight composite floor. In this paper, a complete structural checking methodology has been developed for analyzing all the limit states that determine the final sizing of a steel–concrete composite floor treated with CLD, including a detailed analysis of the VSLS. The methodology has been used for setting a structural optimization problem for floors with and without CLD treatments. Thus, it has been demonstrated that the integration of CLD treatments at the design stage of the building allows the development of lighter floor structures with a smaller embodied carbon (EC) footprint, especially for long-span schemes with restrictive vibration limitations.

16 August 2023 in Structures
Verified
Journal Article
Closed access
CRCarlos M. C. Renedo
Carlos M. C. Renedo
Iván M. DíazIván M. Díaz
Iván M. Díaz
JGJaime H. García-Palacios
Jaime H. García-Palacios

10 January 2025 in Engineering Structures
Verified
Journal Article
Open access
BVBelén Vecino
Belén Vecino
CRCarlos M. C. Renedo
Carlos M. C. Renedo
Jaime H. García-PalaciosJaime H. García-Palacios
Jaime H. García-Palacios
Iván M. DíazIván M. Díaz
Iván M. Díaz

9 September 2024 in International Journal of Structural Stability and Dynamics
Verified
Journal Article
Closed access
Jose M. SoriaJose M. Soria
Jose M. Soria
JAJavier Fernando Jiménez Alonso
Javier Fernando Jiménez Alonso
CRCarlos M. C. Renedo
Carlos M. C. Renedo
CGChristian Gallegos-Calderón
Christian Gallegos-Calderón

28 December 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LCLuis Chillitupa-Palomino
Luis Chillitupa-Palomino
CRCarlos M. C. Renedo
Carlos M. C. Renedo
Jaime H. García-PalaciosJaime H. García-Palacios
Jaime H. García-Palacios
Iván M. DíazIván M. Díaz
Iván M. Díaz
Cables and tendons are crucial elements in bridge engineering but also are vulnerable structural elements because they are usually subjected to fatigue and corrosion problems. Thus, vibration-based non-destructive techniques have been used for external post-tensioning tendon assessment. Regarding continuous monitoring systems, tendon assessment is carried out through the continuous tracking of its natural frequencies and the subsequent estimation of the tension force, as this parameter is essential for the bridge’s overall structural performance, thus providing useful information about bridge safety. However, for long-term monitoring assessment, two main challenges have to be addressed regarding practical applications: (i) double-peak spectra and other spurious factors that affect the frequency estimation, and (ii) temperature dependency, which needs to be carefully treated since frequency/tension variation may be explained by temperature variation, thus masking potential structural anomalies. On this subject, this paper presents the experimental long-term monitoring of several post-tensioning external tendons in a high-speed railway bridge in which a sectorized weighted peak-picking frequency identification procedure is proposed for frequency estimation, alongside a cascade clustering process, which allows meaningful frequency estimates to be selected. Finally, the selected frequency estimates, which show variations from 1 to 2% for all analyzed frequencies, are used for the long-term assessment of the tension force.