Gerald E. McDonnell

Dr. Gerald E. McDonnell

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2010 in Letters in Applied Microbiology
Verified
Journal Article
Closed access
PDF file
MEM. Eterpi
M. Eterpi
GMGerald E. McDonnell
Gerald E. McDonnell
VTV. Thomas
V. Thomas

22 November 2015 in Journal of Applied Microbiology
Verified
Journal Article
Open access
PDF file
DMDeborah J H Martin
Deborah J H Martin
RWRebecca R Wesgate
Rebecca R Wesgate
SDStephen P Denyer
Stephen P Denyer
GMGerald E. McDonnell
Gerald E. McDonnell
JMJean-Yves Maillard
Jean-Yves Maillard
Oxidizing agents such as chlorine dioxide are widely used microbicides, including for disinfection of medical equipment. We isolated a Bacillus subtilis isolate from a washer-disinfector whose vegetative form demonstrated unique resistance to chlorine dioxide (0·03%) and hydrogen peroxide (7·5%). The aim of this study was to understand the mechanisms of resistance expressed by this isolate. A range of resistance mechanisms were investigated in the B. subtilis isolate and a reference B. subtilis strain (ATCC 6051) to include bacterial cell aggregation, the presence of profuse exopolysaccharide (EPS), and the expression of detoxification enzymes. The basis of resistance of the isolate to high concentrations of oxidizing agents was not linked to the presence of endospores. Although, the presence of EPS, aggregation and expression of detoxification enzymes may play a role in bacterial survival to low concentrations of chlorine dioxide, it is unlikely that the mechanisms helped tested to survive the bactericidal effect of higher oxidizer concentrations. Overall, the mechanisms conferring resistance to chlorine dioxide and hydrogen peroxide remains elusive. Based on recent advances in the mode of action of oxidizing agents and notably hydrogen peroxide, we postulate that additional efficient intracellular mechanisms may be involved to explain significant resistance to in-use concentrations of commonly used high-level disinfectants. The isolation of a highly resistant vegetative Gram-positive bacterium to a highly reactive oxidizing agent is worrying. Understanding the mechanisms conferring such resistance is essential to effectively control such bacterial isolates. Here, we postulate that there are still mechanisms of bacterial resistance that have not been fully characterized.

2 April 2016 in Biomedical Instrumentation & Technology
Verified
Journal Article
Closed access
PMPatrick J. McCormick
Patrick J. McCormick
MSMichael J. Schoene
Michael J. Schoene
MDMatthew A. Dehmler
Matthew A. Dehmler
GMGerald E. McDonnell
Gerald E. McDonnell
MMMichael J. Schoene Patrick J. McCormick
Michael J. Schoene Patrick J. McCormick
Moist heat is employed in the medical device, pharmaceutical, and food processing industries to render products and goods safe for use and human consumption. Applications include its use to pasteurize a broad range of foods and beverages, the control of microbial contamination of blood products, and treatment of bone tissue transplants and vaccines. In the pharmaceutical industry, water heated to 65°C to 80°C is used to sanitize high-purity water systems. In healthcare, it has been employed for decades to disinfect patient care items ranging from bedpans to anesthesia equipment. There is a good understanding of the conditions necessary to achieve disinfection of microorganisms at temperatures ranging from 65°C to 100°C. Based on this information, the efficacy of moist heat processes at a range of exposure times and temperatures can be quantified based on mathematical models such as the A0 calculation. While the A0 concept is recognized within the European healthcare community, it has yet to be widely adopted within the United States. This article provides information regarding the A0 concept, a brief overview of the classification of thermal disinfection for use with healthcare applications within the United States, and recent data on reinvestigating the thermal disinfection of a selected panel of microorganisms and a mixed culture biofilm.

1 January 2021 in Biomedical Instrumentation & Technology
Verified
Journal Article
Closed access
PDF file
AMAlan Montgomery
Alan Montgomery
Romain Bolle-ReddatRomain Bolle-Reddat
Romain Bolle-Reddat
SFShari Formica
Shari Formica
BLBradley Lundahl
Bradley Lundahl
GMGerald E. McDonnell
Gerald E. McDonnell
When investing in X-ray irradiation facilities around the world, an opportunity exists for defining a regulatory framework for assessing the transition from current gamma irradiation processes. Historically, regulatory strategies for changing the radiation source for routine processing has consisted of repeating the majority, if not all, of the validation activities performed as part of an initial validation and associated submission. Although not a new concept, performing a risk assessment has the potential to be leveraged more fully by increasing the rigor of determining what is changing when product moves from a gamma to an X-ray irradiator, then determining how these differences may affect product characteristics. During these steps, differences can be identified and quantified between radiation sources and potential impacts, if any, to product quality can be elucidated. Based on these risk assessments, the level of action required, or not required, in terms of empirical product testing can be examined and a determination can be made regarding whether a substantial change has occurred.

1 October 2023 in Biomedical Instrumentation & Technology
Verified
Journal Article
Closed access
AKAllan Wayne Kimble
Allan Wayne Kimble
JHJames Hauschild
James Hauschild
GMGerald E. McDonnell
Gerald E. McDonnell
Endotoxins are high-molecular-weight complexes that contain lipopolysaccharide, protein, and phospholipid originating from the outer membrane of gram-negative bacteria. As gram-negative bacteria are naturally present in a variety of sources, endotoxins are commonly identified as contaminants in manufacturing environments. In industrial applications, endotoxin often is considered difficult to inactivate and to have a strong affinity with surfaces resulting from its hydrophobic chemical structure. This article describes the investigation of the true affinity of endotoxin, from various microbial sources in solution, for medical device material surfaces. In addition, endotoxin reduction was investigated with commonly used sterilization methods such as those based on ionizing radiation, dry and moist heat, and ethylene oxide sterilization. Endotoxin activity was found to be reduced following exposure to a range of sterilization modalities with the degree of activity reduction related to the source of endotoxin and the substrate material upon which it was present.

16 October 2024 in Journal of Hospital Infection
Verified
Journal Article
Open access
TKTerra Kremer
Terra Kremer
Neil RowanNeil Rowan
Neil Rowan
GMGerald E. McDonnell
Gerald E. McDonnell
The cleaning of reusable medical devices involves inherent challenges that can impact on the effectiveness of the cleaning process; consequently, the subsequent safety of patients. Fluid dynamics play a critical role in determining the flow and distribution of cleaning agents where the design of the device can either facilitate or hinder this important process. Complex geometries, narrow channels, or irregular surfaces can impede effective flushing of contaminants leading to incomplete cleaning that creates a greater likelihood for patient contamination risks. Device features (N = 23) were exposed to the most challenging cleaning conditions to find the point of failure in both fluid dynamics and soil retention. Experimental results obtained from the aforementioned along with associated compound risks were used to assign a risk value. Using the 'hardest to clean' device feature approach as the base risk value, the total quantitative risk score was calculated for different reusable medical devices from numerical values obtained from addressing 14 questions focusing on variability in geometry, material use, types of cleaning, and intended patient use. Patient risk values for devices with different features were calculated from using Kremer's cleaning categories based on position within value ranges. Occurrences less than 18 correspond to minimal risk devices while a total risk score between the values of 18 and 39 are moderate and ≥40 scores corresponds to the maximal category. Application of this quantitative assessment approach will facilitate appropriate mitigation of risk for cleaning reusable medical devices by informing use of targeted effective interventions. Future use of this Kremer cleaning classification will complement and augment disinfection and sterilization modalities.