The identification of worst-case device (or device set) features has been a well-established validation approach in many areas (e.g., terminal sterilization) for determining process effectiveness and requirements, including for reusable medical devices. A device feature approach for cleaning validations has many advantages, representing a more conservative approach compared with the alternative compendial method of testing the entirety of the device. By focusing on the device feature(s), the most challenging validation variables can be isolated to and studied at the most difficult-to-clean feature(s). The device feature approach can be used to develop a design feature database that can be used to design and validate device cleanliness. It can also be used to commensurately develop a quantitative cleaning classification system that will augment and innovate the effectiveness of the Spaulding classification for microbial risk reduction. The current study investigated this validation approach to verify the efficacy of device cleaning procedures and mitigate patient risk. This feature categorization approach will help to close the existing patient safety gap at the important interface between device manufacturers and healthcare facilities for the effective and reliable processing of reusable medical devices. A total of 56,000 flushes of the device features were conducted, highlighting the rigor associated with the validation. Generating information from design features as a critical control point for cleaning and microbiological quality will inform future digital transformation of the medical device industry and healthcare delivery, including automation.
The cleaning of reusable medical devices involves inherent challenges that can impact on the effectiveness of the cleaning process; consequently, the subsequent safety of patients. Fluid dynamics play a critical role in determining the flow and distribution of cleaning agents where the design of the device can either facilitate or hinder this important process. Complex geometries, narrow channels, or irregular surfaces can impede effective flushing of contaminants leading to incomplete cleaning that creates a greater likelihood for patient contamination risks. Device features (N = 23) were exposed to the most challenging cleaning conditions to find the point of failure in both fluid dynamics and soil retention. Experimental results obtained from the aforementioned along with associated compound risks were used to assign a risk value. Using the 'hardest to clean' device feature approach as the base risk value, the total quantitative risk score was calculated for different reusable medical devices from numerical values obtained from addressing 14 questions focusing on variability in geometry, material use, types of cleaning, and intended patient use. Patient risk values for devices with different features were calculated from using Kremer's cleaning categories based on position within value ranges. Occurrences less than 18 correspond to minimal risk devices while a total risk score between the values of 18 and 39 are moderate and ≥40 scores corresponds to the maximal category. Application of this quantitative assessment approach will facilitate appropriate mitigation of risk for cleaning reusable medical devices by informing use of targeted effective interventions. Future use of this Kremer cleaning classification will complement and augment disinfection and sterilization modalities.
Cleaning chemistries are detergent-based formulations that are used during the processing of reusable medical devices. Manufacturers are responsible for demonstrating the safety of cleaning formulations when they are used during a device processing cycle, including the risk of device-associated cytotoxicity over the concentration ranges for recommended use and rinsing during cleaning. However, no regulation currently exists requiring manufacturers to demonstrate such safety. Although manufacturers' safety data sheets (SDSs) provide information on the safe use of chemicals for users, this information may not provide sufficient detail to determine the risks of residual chemicals on device surfaces. SDSs are not required to contain a comprehensive list of chemicals used, only those of risk to the user. They should be supplemented with information on the correct concentrations that should be used for cleaning, as well as instructions on the rinsing required to reduce the levels of chemicals to safe (nontoxic) levels prior to further processing. Supporting data, such as toxicity profiles or cytotoxicity data that support the instructions for use, would provide medical device manufacturers and healthcare personnel with the necessary information to make informed decisions about selection and correct use of detergents. In the current work, cytotoxicity profiles for eight commonly used cleaning formulations available internationally were studied. Although all of these products are indicated for use in the cleaning of reusable medical devices, results vary across the serial dilution curves and are not consistent among detergent types. The information presented here can be leveraged by both medical device manufacturers and processing department personnel to properly assess residual detergent risks during processing. This work also serves as a call to cleaning formulation manufacturers to provide this information for all chemistries.
1 July 2020 in Biomedical Instrumentation & Technology
Article Citation: Terra A. Kremer and Gerald McDonnell (2020) Sterilization Central: Water Quality in Medical Device Processing: The Power of Prevention. Biomedical Instrumentation & Technology: July/August 2020, Vol. 54, No. 4, pp. 304-309. https://doi.org/10.2345/0899-8205-54.4.304