A plastic optical fiber (POF) probe with a macro-bending tapered structure was proposed and optimized for the refractive index (RI) sensing. The principle of operation is based on the macro-bending loss and evanescent wave, which are introduced by the macro-bending tapered structure on the fiber, and modulated by the environmental RI. A heating and drawing method and thermal setting process were used to fabricate a tapered POF and form a stable macro-bending structure for the probe. The probes with cladding and without cladding were fabricated. By changing the taper waist and curvature radius, the sensing performance of the probe was optimized. The highest sensitivity of the probe with cladding reached 937%/RIU in the RI range of 1.33-1.41. By removing the cladding, the RI sensing range was expanded to 1.33-1.45, and the sensitivity was about 800%/RIU, lower than the ones with cladding. In addition, the temperature dependence of the sensor was investigated. The POF probe is a low cost solution for RI sensing applications, which has the features of simple structure, compact, and intensity modulation at visible wavelength.
In this paper, we introduce a refractive index (RI) sensor based on the surface plasmon resonance (SPR) effect. A commercial plastic optical fiber (POF) is fabricated with a D-shaped macrobend structure by heat setting and side polishing techniques to expose the core and enhance RI sensitivity. Gold is sputtered onto the polished surface of the POF, generating a film with a thickness of approximately 10 nm. When the RI of the environment changes, the propagation attenuation in the macrobend section and the SPR spectrum change simultaneously. Therefore, the RI can be determined by the dual mechanism of bending loss and spectral shift. The experimental results show that as the RI of the immersion liquid varies from 1.33 to 1.40, the sensing probe exhibits a bending loss change and a spectral shift. This result indicates that the sensitivities of the probe in regard to bending loss and SPR are 43 dB/RIU and 1570 nm/RIU, respectively.
In this work, a biosensing method based on in situ, fast, and sensitive measurements of ellipsometric parameters (Ψ, ∆) is proposed. Bare silicon wafer substrate is functionalized and used to bind biomolecules in the solution. Coupled with a 45° dual-drive symmetric photoelastic modulator-based ellipsometry, the parameters Ψ and ∆ of biolayer arising due to biomolecular interactions are determined directly, and the refractive index (RI) of the solution and the effective thickness and surface mass density of the biolayer for various interaction time can be further monitored simultaneously. To illustrate the performance of the biosensing method, immunosensing for immunoglobulin G (IgG) was taken as a case study. The experiment results show that the biosensor response of the limit of detection for IgG is 15 ng/mL, and the data collection time is in milliseconds. Moreover, the method demonstrates a good specificity. Such technique is a promising candidate in developing a novel sensor which can realize fast and sensitive, label-free, easy operation, and cost-effective biosensing.
Purpose: This paper aims to propose a liquid level sensor with a multi-S-bend plastic optical fiber. Design/methodology/approach: The principle of liquid sensing used is based on the leakage of higher modes out of the fiber and repeated regeneration in the following bend sections. Therefore, a propagation loss was introduced in every bend section of the fiber with the loss depending on the refractive index of the environment. Findings: Therefore, a continue shift in the liquid level can be detected by observing changes in the propagation loss of the fiber. The sensor features compactness and a flexible resolution. Originality/value: Compared with the exited ones, the sensor has capability of continue liquid measurement and a greater measurement range.
A novel approach to achieving ultrafast real-time user localization in optically controlled beam-steering wireless communications (OWC) is proposed and demonstrated in this letter. Ultrafast wavelength encoded user localization at 50 MHz rate is achieved based on photonic time stretch concept and a passive beam scanner using a 45° tilted fibre grating (TFG). Not only the angular separation but also the linear distance from the access point can be determined simultaneously. More importantly, challenging instantaneous optical wavelength identification within nanosecond range is successfully achieved through chirped microwave frequency encoding and reservoir computing (RC) based frequency identification. A proof-of-concept experiment was carried out to verify the proposed approach. The results show that RC is more efficient in frequency chirp identification than the conventional short-time Fourier transform approach.