Hui Chai-Gao

Dr. Hui Chai-Gao


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
YTYe Tang
Ye Tang
KPKonstantinos Petropoulos
Konstantinos Petropoulos
FKFelix Kurth
Felix Kurth
HCHui Chai-Gao
Hui Chai-Gao
DMDavide Migliorelli
Davide Migliorelli
SGSilvia Generelli
Silvia Generelli
Glucose sensors are potentially useful tools for monitoring the glucose concentration in cell culture medium. Here, we present a new, low-cost, and reproducible sensor based on a cellulose-based material, 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO) oxidized-cellulose nanocrystals (CNCs). This novel biocompatible and inert nanomaterial is employed as a polymeric matrix to immobilize and stabilize glucose oxidase in the fabrication of a reproducible, operationally stable, highly selective, cost-effective, screen-printed glucose sensor. The sensors have a linear range of 0.1–2 mM (R2 = 0.999) and a sensitivity of 5.7 ± 0.3 µA cm−2∙mM−1. The limit of detection is 0.004 mM, and the limit of quantification is 0.015 mM. The sensor maintains 92.3 % of the initial current response after 30 consecutive measurements in a 1 mM standard glucose solution, and has a shelf life of 1 month while maintaining high selectivity. We demonstrate the practical application of the sensor by monitoring the glucose consumption of a fibroblast cell culture over the course of several days.

21 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
SDSilvia Demuru
Silvia Demuru
HCHui Chai-Gao
Hui Chai-Gao
YSYevhen Shynkarenko
Yevhen Shynkarenko
NHNicola Hermann
Nicola Hermann
PBPatricia-Daiana Boia
Patricia-Daiana Boia
LBLoïc Burr
Loïc Burr
With the steady increase in allergy prevalence worldwide, there is a strong need for novel diagnostic tools for precise, fast, and less invasive testing methods. Herein, a miniatured fluorescence-based biosensing system is developed for the rapid and quantitative detection of allergen-specific immunoglobulin-E. An antibody-based fluorescence assay in a microfluidic-patterned slide, combined with a custom-made portable fluorescence reader for image acquisition and user-friendly software for the data analysis, enables obtaining results for multiple allergens in just ~1 h with only 80 μL of blood serum. The multiplexed detection of common birch, timothy grass, cat epithelia, house dust mite, and dog epithelia shows quantitative IgE-mediated allergic responses to specific allergens in control serum samples with known total IgE concentration. The responses are verified with different control tests and measurements with a commercial fluorescence reader. These results open the door to point-of-care allergy screening for early diagnosis and broader access and for large-scale research in allergies.

8 September 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
HCHui Chai-Gao
Hui Chai-Gao
SGSilvia Generelli
Silvia Generelli
FHFriedrich Heitger
Friedrich Heitger
This work presents a demonstrator for online monitoring of pesticides or water contaminants which is robust, fast, specific and low cost. The system is designed for continuous monitoring in water matrices (source- and surface water, treated waste water), and is thus completed with an automated fluidics. The main characteristics of the system are: (a) Detection based on competitive immunoassay; (b) Label-free sensing with possibility of following the binding kinetics of the contaminants; (c) Modular sensing surfaces characteristics; (d) In-assay calibration/normalization; (e) Re-generable biochip >80 times; (f) Detection limit of the analyte, the pesticide atrazine, 0.05 µg/L; (g) Computational Bioanalytics; (h) Compensation of the interfering effects.

10 April 2024 in Proceedings
Verified
Conference Paper
Open access
PDF file
HCHui Chai-Gao
Hui Chai-Gao
YSYevhen Shynkarenko
Yevhen Shynkarenko
SDSilvia Demuru
Silvia Demuru
NHNicola Hermann
Nicola Hermann
PBPatricia-Daiana Boia
Patricia-Daiana Boia
LBLoïc Burr
Loïc Burr
A miniaturized multi-array system is being developed for immune-signature testing. The presented system includes microfluidic chips functionalized with allergens for IgE detection and a custom-made portable reader for fast (~1 s), quantitative, and sensitive (500 dye molecules/μm2) detection, with a high spatial resolution (~50–100 μm). The developed solution enables the rapid sensing of allergic reactions at the point of care with a low-cost portable device.