Silvia Generelli

Silvia Generelli


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2021 in Foods
Verified
Journal Article
Open access
PDF file
SJSafiye Jafari
Safiye Jafari
JGJulian Guercetti
Julian Guercetti
AGAriadni Geballa-Koukoula
Ariadni Geballa-Koukoula
Aristeidis TsagkarisAristeidis Tsagkaris
Aristeidis Tsagkaris
JNJoost Laurus Dinant Nelis
Joost Laurus Dinant Nelis
SSShana Sturla
Shana Sturla
Standard methods for chemical food safety testing in official laboratories rely largely on liquid or gas chromatography coupled with mass spectrometry. Although these methods are considered the gold standard for quantitative confirmatory analysis, they require sampling, transferring the samples to a central laboratory to be tested by highly trained personnel, and the use of expensive equipment. Therefore, there is an increasing demand for portable and handheld devices to provide rapid, efficient, and on-site screening of food contaminants. Recent technological advancements in the field include smartphone-based, microfluidic chip-based, and paper-based devices integrated with electrochemical and optical biosensing platforms. Furthermore, the potential application of portable mass spectrometers in food testing might bring the confirmatory analysis from the laboratory to the field in the future. Although such systems open new promising possibilities for portable food testing, few of these devices are commercially available. To understand why barriers remain, portable food analyzers reported in the literature over the last ten years were reviewed. To this end, the analytical performance of these devices and the extent they match the World Health Organization benchmark for diagnostic tests, i.e., the Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, and Deliverable to end-users (ASSURED) criteria, was evaluated critically. A five-star scoring system was used to assess their potential to be implemented as food safety testing systems. The main findings highlight the need for concentrated efforts towards combining the best features of different technologies, to bridge technological gaps and meet commercialization requirements.

24 June 2022 in Analytica Chimica Acta
Verified
Journal Article
Open access
SJSafiye Jafari
Safiye Jafari
LBLoïc Burr
Loïc Burr
DMDavide Migliorelli
Davide Migliorelli
RGRoger Galve
Roger Galve
MMM.-Pilar Marco
M.-Pilar Marco
SGSilvia Generelli
Silvia Generelli
Considering the complexities and speed of modern food chains, there is an increasing demand for point-of-need detection of food contaminants, particularly highly regulated chemicals and carcinogens such as aflatoxin B1. We report a user-friendly smartphone-based magneto-immunosensor on carbon black modified electrodes for point-of-need detection of aflatoxin B1 in cereals. For buffered analyte solutions and a corn extract sample, the assay demonstrated a low limit of detection of 13 and 24 pg/mL, respectively. The assay was also highly reproducible, exhibiting mean relative standard deviations of 3.7% and 4.0% for the buffered analyte and corn extract samples. The applicability of the assay was validated on the basis of EU guidelines and the detection capability was lower than or equal to 2 μg/kg, which is the EU maximum residue limit for aflatoxin B1 in cereals. False-positive and false-negative rates were less than 5%. Additionally, an open-source android application, AflaESense, was designed to provide a simple interface that displays the result in a traffic-light-type format, thus minimizing user training and time for data analysis. AflaESense was used for smartphone-based screening of spiked corn samples containing aflatoxin B1 (0.1, 2, and 10 ng/mL), and naturally contaminated corn containing 0.15 ng aflatoxin B1/mL. The measured values were in close agreement with spiked concentrations (r2 = 0.99), with recovery values ranging between 80 and 120%. Finally, contaminated samples correctly triggered a red alert while the non-contaminated samples led to the display of a green color of AflaESense. To the best of our knowledge, this is the first smartphone-based electrochemical system effective for screening samples for contamination with aflatoxin B1.

13 September 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
YTYe Tang
Ye Tang
KPKonstantinos Petropoulos
Konstantinos Petropoulos
FKFelix Kurth
Felix Kurth
HCHui Chai-Gao
Hui Chai-Gao
DMDavide Migliorelli
Davide Migliorelli
SGSilvia Generelli
Silvia Generelli
Glucose sensors are potentially useful tools for monitoring the glucose concentration in cell culture medium. Here, we present a new, low-cost, and reproducible sensor based on a cellulose-based material, 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO) oxidized-cellulose nanocrystals (CNCs). This novel biocompatible and inert nanomaterial is employed as a polymeric matrix to immobilize and stabilize glucose oxidase in the fabrication of a reproducible, operationally stable, highly selective, cost-effective, screen-printed glucose sensor. The sensors have a linear range of 0.1–2 mM (R2 = 0.999) and a sensitivity of 5.7 ± 0.3 µA cm−2∙mM−1. The limit of detection is 0.004 mM, and the limit of quantification is 0.015 mM. The sensor maintains 92.3 % of the initial current response after 30 consecutive measurements in a 1 mM standard glucose solution, and has a shelf life of 1 month while maintaining high selectivity. We demonstrate the practical application of the sensor by monitoring the glucose consumption of a fibroblast cell culture over the course of several days.

1 November 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
YTYe Tang
Ye Tang
HGHui Gao
Hui Gao
FKFelix Kurth
Felix Kurth
LBLoïc Burr
Loïc Burr
KPKonstantinos Petropoulos
Konstantinos Petropoulos
SGSilvia Generelli
Silvia Generelli

31 March 2023 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
WCWanda Cimmino
Wanda Cimmino
DMDavide Migliorelli
Davide Migliorelli
SSSima Singh
Sima Singh
AMAntonella Miglione
Antonella Miglione
SGSilvia Generelli
Silvia Generelli
Stefano CintiStefano Cinti
Stefano Cinti
MicroRNAs (miRNAs) are clinical biomarkers for various human diseases, including cancer. They have been found in liquid biopsy samples, including various bodily fluids. They often play an important role in the early diagnosis and prognosis of cancer, and the development of simple and effective analytical methods would be of pivotal importance for the entire community. The determination of these targets may be affected by the different physicochemical parameters of the specimen of interest. In this work, an electrochemical detection platform for miRNA based on a screen-printed gold electrode was developed. In the present study, miRNA-21 was selected as a model sequence, due to its role in prostate, breast, colon, pancreatic, and liver cancers. A DNA sequence modified with methylene blue (MB) was covalently bound to the electrochemical strip and used to detect the selected target miRNA-21. After optimization of selected parameters in standard solutions, including the study of the effect of pH, the presence of interferent species, and NaCl salt concentration in the background, the application of square-wave voltammetry (SWV) technique allowed the detection of miRNA-21 down to a limit in the order of 2 nM. The developed device was then applied to several urine samples. In this case too, the device showed high selectivity in the presence of the complex matrix, satisfactory repeatability, and a limit of detection in the order of magnitude of nM, similarly as what observed in standard solutions.

8 September 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
HCHui Chai-Gao
Hui Chai-Gao
SGSilvia Generelli
Silvia Generelli
FHFriedrich Heitger
Friedrich Heitger
This work presents a demonstrator for online monitoring of pesticides or water contaminants which is robust, fast, specific and low cost. The system is designed for continuous monitoring in water matrices (source- and surface water, treated waste water), and is thus completed with an automated fluidics. The main characteristics of the system are: (a) Detection based on competitive immunoassay; (b) Label-free sensing with possibility of following the binding kinetics of the contaminants; (c) Modular sensing surfaces characteristics; (d) In-assay calibration/normalization; (e) Re-generable biochip >80 times; (f) Detection limit of the analyte, the pesticide atrazine, 0.05 µg/L; (g) Computational Bioanalytics; (h) Compensation of the interfering effects.