For rubber-like materials, there are three popular methods of equibiaxial tension available: inflation tension, equibiaxial planar tension, and radial tension. However, no studies have addressed the accuracy and comparability of these tests. In this work, we model the tension tests for a hyperelastic electroactive polymer (EAP) membrane material using finite element method (FEM) and investigate their experimental accuracy. This study also analyzes the impact of apparatus structure parameters and specimen dimensions on experimental performances. Additionally, a tensile efficiency is proposed to assess non-uniform deformation in equibiaxial planar tension and radial tension tests. The sample points for calculating deformation in inflation tensions should be taken near the top of the inflated balloon to obtain a more accurate characteristic curve; the deformation simulation range will be constrained by the material model and its parameters within a specific limit (λ ≈ 1.9); if the inflation hole size is halved, the required air pressure must be doubled to maintain equivalent stress and strain values, resulting in a reduction in half in inflation height and decreased accuracy. The equibiaxial planar tension test can enhance uniform deformation and reduce stress errors to as low as 2.1% (at λ = 4) with single-corner-point tension. For circular diaphragm specimens in radial tension tests, increasing the number of cuts and using larger punched holes results in more uniform deformation and less stress error, with a minimum value of 3.83% achieved for a specimen with 24 cuts and a 5 mm punched hole. In terms of tensile efficiency, increasing the number of tensile points in the equibiaxial planar tension test can improve it; under radial tension, increasing the number of cuts and decreasing the diameter of the punched hole on the specimen has a hedging effect. The findings of this study are valuable for accurately evaluating various equibiaxial tension methods and analyzing their precision, as well as providing sound guidance for the effective design of testing apparatus and test plans.
The equibiaxial planar tension test is an important method for determining the mechanical properties of hyperplastic membranes, and it is also critical to designing an effective equibiaxial tension test rig to meet experimental accuracy requirements. However, any analysis addressing the accuracy of this test is not reported in the literature. In this paper, an equibiaxial planar tension apparatus is proposed for conducting single-corner-point tension tests on hyperelastic electroactive polymer (EAP) membranes. The experimental data were compared with those obtained from two-corner-point-fixed tension tests and fitted with nonlinear material models, and the model’s parameters were also evaluated. Finally, the widely-used finite element software ABAQUS was employed to simulate equibiaxial planar tension methods and investigate the impact of clamping mode and point number on test accuracy as well as the uniformity of overall deformation. The test results indicate that the stress-strain curves for the two tensions remain consistent across small stretch ratios. However, as the stretch ratio increases (about ) in two-corner-point-fixed tension, stress shielding may lead to a degradation of strain uniformity and result in greater stresses than single-corner-point tension. Additionally, both the three-parameter Yeoh model and the four-parameter Ogden model can provide an accurate description of the EAP membrane material. The simulation results indicate that the axial strain variation amplitudes remain below 5% within a region spanning approximately 80% of the specimen’s overall length from its center to edge and even below 1% within a region spanning 85% in the single-corner-point tension; stress inaccuracies increase with stretch ratio, while the calculated error is about 2.1% when in the single-corner-point tension test, which has the smallest stress error among the tests; when the number of tension points is increased, the overall deformation becomes more sufficient, and the test accuracy improves as well. The conclusions drawn from this paper will be beneficial in designing equibiaxial planar tension test rigs and analyzing their accuracy and uniformity of deformation.
Equibiaxial tension tests for hyperelastic electroactive polymers (EAPs) are important means to obtain the mechanical properties. There are three main methods: equibiaxial planar tension, radial tension and bulge test. The finite element analysis software is used to model and analyze the influence of testing apparatus, specimen geometric parameters on the test results and accuracy. The results show that the uniformity of the deformation of the square film can be effectively improved by using single corner point fixed tension in equibiaxial planar tension test, and the force error also decreased; the number of the cuts and the size of punched holes should be appropriate in radial tension test of circular diaphragm specimen to avoid the material strength failure caused by excessive tension along the edge of transition arc between grips and excessive deformation of tensile belt between the cuts; in bulge test, the sampled deformation data should be near the spherical pole to obtain more accurate stress-strain relationship owing to contour error and non-uniform deformation, a certain range of model parameters will limit the scope of simulation analysis. This paper proposed research provides guidance for the design of equibiaxial tension test apparatus and method to obtain more accurate test results.