Vance Bergeron

Dr. Vance Bergeron

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2013 in Oil & Gas Science and Technology – Revue d’IFP Energies nouvelles
Verified
Journal Article
Open access
PDF file
CBChristian Blázquez
Christian Blázquez
EEEliane Emond
Eliane Emond
SSSophie Schneider
Sophie Schneider
CDChristine Dalmazzone
Christine Dalmazzone
Vance BergeronVance Bergeron
Vance Bergeron

5 December 2017 in European Journal of Translational Myology
Verified
Journal Article
Open access
PDF file
AMAmine Metani
Amine Metani
LPLana Popovic-Maneski
Lana Popovic-Maneski
SMSebastien Mateo
Sebastien Mateo
LLLaura Lemahieu
Laura Lemahieu
Vance BergeronVance Bergeron
Vance Bergeron
Whether it is from the patient’s or the physical therapist’s point of view, FES cycling can be considered either as a recreational activity, or an engaging rehabilitation tool. In both cases, it keeps patients with lower-limb paralysis motivated to sustain a regular physical activity. Thus, it is not surprising that it was selected as one of the six disciplines of the first Cybathlon competition held on October 8, 2016. However, many unresolved issues prevent FES cycling from being an activity practiced outdoors on a daily basis; such as, low power production, rapid muscle fatigue, precise electrode positioning, lack of systematic procedures to determine stimulation patterns, and the difficulty of transferring disabled riders from their wheelchair to the tricycle. This article documents the challenges we faced during preparation for the Cybathlon 2016 FES cycling race, and provides results obtained during different phases of the process. A particular specificity of our team was that, unlike most other teams where pilots were mainly paraplegic, both the primary and backup pilots for team ENS de Lyon are C6/C7 tetraplegics, with neither voluntary control of their abdominal muscles nor hand grip, and only partial use of their arms.

1 October 2007 in Infection Control & Hospital Epidemiology
Verified
Journal Article
Closed access
PDF file
Vance BergeronVance Bergeron
Vance Bergeron
GRG. Reboux
G. Reboux
JPJ. L. Poirot
J. L. Poirot
NLN. Laudinet
N. Laudinet
Objective.: To evaluate the performance of a new mobile air-treatment unit that uses nonthermal-plasma reactors for lowering the airborne bioburden in critical hospital environments and reducing the risk of nosocomial infection due to opportunistic airborne pathogens, such asAspergillus fumigatus.Methods.: Tests were conducted in 2 different high-risk hospital areas: an operating room under simulated conditions and rooms hosting patients in a pediatric hematology ward. Operating room testing provided performance evaluations of removal rates for airborne contamination (ie, particles larger than 0.5μm) and overall lowering of the airborne bioburden (ie, colony-forming units of total mesophilic flora and fungal flora per cubic meter of air). In the hematology service, opportunistic and nonpathogenic airborne fungal levels in a patient's room equipped with an air-treatment unit were compared to those in a control room.Results.: In an operating room with a volume of 118 m3, the time required to lower the concentration of airborne particles larger than 0.5μm by 90% was decreased from 12 minutes with the existing high-efficiency particulate air filtration system to less than 2 minutes with the units tested, with a 2-log decrease in the steady-state levels of such particles (P<.01). Concurrently, total airborne mesophilic flora concentrations dropped by a factor of 2, and the concentrations of fungal species were reduced to undetectable levels (P<.01). The 12-day test period in the hematology ward revealed a significant reduction in airborne fungus levels (P<.01), with average reductions of 75% for opportunistic species and 82% for nonpathogenic species.Conclusion.: Our data indicate that the mobile, nonthermal-plasma air treatment unit tested in this study can rapidly reduce the levels of airborne particles and significantly lower the airborne bioburden in high-risk hospital environments.

3 March 2011 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
CBChristian Beauchêne
Christian Beauchêne
NLNicolas Laudinet
Nicolas Laudinet
FCFiras Choukri
Firas Choukri
JRJean-Luc Rousset
Jean-Luc Rousset
SBSofiane Benhamadouche
Sofiane Benhamadouche
FDFrancis Derouin
Francis Derouin
Controlling airborne contamination is of major importance in burn units because of the high susceptibility of burned patients to infections and the unique environmental conditions that can accentuate the infection risk. In particular the required elevated temperatures in the patient room can create thermal convection flows which can transport airborne contaminates throughout the unit. In order to estimate this risk and optimize the design of an intensive care room intended to host severely burned patients, we have relied on a computational fluid dynamic methodology (CFD).

5 December 2017 in European Journal of Translational Myology
Verified
Journal Article
Open access
PDF file
CCChristine Azevedo Coste
Christine Azevedo Coste
Vance BergeronVance Bergeron
Vance Bergeron
RBRik Berkelmans
Rik Berkelmans
EFEmerson Fachin-Martins
Emerson Fachin-Martins
CFChe Fornusek
Che Fornusek
Peter WolfPeter Wolf
Peter Wolf
Functional Electrical Stimulation (FES) can elicit muscular contraction and restore motor function in paralyzed limbs. FES is a rehabilitation technique applied to various sensorimotor deficiencies and in different functional situations, e.g. grasping, walking, standing, transfer, cycling and rowing. FES can be combined with mechanical devices. FES-assisted cycling is mainly used in clinical environments for training sessions on cycle ergometers, but it has also been adapted for mobile devices, usually tricycles. In October 2016, twelve teams participated in the CYBATHLON competition in the FES-cycling discipline for persons with motor-complete spinal cord injury. It was the first event of this kind and a wide variety of strategies, techniques and designs were employed by the different teams in the competition. The approaches of the teams are detailed in this special issue. We hope that the knowledge contained herein, together with recent positive results of FES for denervated degenerating muscles, will provide a solid basis to encourage improvements in FES equipment and open new opportunities for many patients in need of safe and effective FES management. We hope to see further developments and/or the benefit of new training strategies at future FES competitions, e.g. at the Cybathlon 2020 (www.cybathlon.ethz.ch).

28 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PKPetar Kajganic
Petar Kajganic
Vance BergeronVance Bergeron
Vance Bergeron
AMAmine Metani
Amine Metani
Background: Functional electrical stimulation (FES) cycling has seen an upsurge in interest over the last decade. The present study describes the novel instrumented cycling ergometer platform designed to assess the efficiency of electrical stimulation strategies. The capabilities of the platform are showcased in an example determining the adequate stimulation patterns for reproducing a cycling movement of the paralyzed legs of a spinal cord injury (SCI) subject. Methods: Two procedures have been followed to determine the stimulation patterns: (1) using the EMG recordings of the able-bodied subject; (2) using the recordings of the forces produced by the SCI subject’s stimulated muscles. Results: the stimulation pattern derived from the SCI subject’s force output was found to produce 14% more power than the EMG-derived stimulation pattern. Conclusions: the cycling platform proved useful for determining and assessing stimulation patterns, and it can be used to further investigate advanced stimulation strategies.