Antonia Patricia Oliveira Barros

Mrs. Antonia Patricia Oliveira Barros


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2021 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
ABAntonia Patricia Oliveira Barros
Antonia Patricia Oliveira Barros
CACristiane de Melo Alencar
Cristiane de Melo Alencar
ACAlexandra de Melo Pingarilho Carneiro
Alexandra de Melo Pingarilho Carneiro
DPDanielle da Silva Pompeu
Danielle da Silva Pompeu
GBGabriela Monteiro Barbosa
Gabriela Monteiro Barbosa
CSCecy Martins SILVA
Cecy Martins SILVA

7 February 2024 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Open access
ETElma Vieira Takeuchi
Elma Vieira Takeuchi
JCJoatan Lucas De Sousa Gomes Costa
Joatan Lucas De Sousa Gomes Costa
CSCarmem Lúcia de Arroxelas Silva
Carmem Lúcia de Arroxelas Silva
ABAntonia Patricia Oliveira Barros
Antonia Patricia Oliveira Barros
BMBarbara Leite Machado
Barbara Leite Machado
CSCecy Martins SILVA
Cecy Martins SILVA
Background: The photo-acceleration of bleaching gels by lights has been extensively researched. However, the induced temperature increase during this process needs to be further evaluated to prevent damage to the dental pulp. Therefore, the objective of this study was to evaluate the surface and intrapulpal temperature kinetics of different concentrations of hydrogen peroxide (HP) gels photo-accelerated by blue or violet light and infrared laser. Methods: The whitening gels at concentrations of HP35, HP15, and HP6 % were irradiated with blue and violet LED/laser on the surface of a human canine tooth. The surface temperature variation (∆Ts) was evaluated using a pH meter, while the intrapulpal temperature variation (∆Ti) was assessed using a digital thermometer at intervals of 1, 15, and 30 min. Statistical analysis was conducted using a Two-way repeated measures ANOVA test, and Bonferroni post-test was applied at a significance level of 5 %. Results: All violet LED photo-accelerated groups showed a higher increase in ∆Ts compared to the blue LED/laser groups. However, there were no significant differences between the groups for ∆Ti. Conclusion: Although the photo-acceleration of HP35 and HP15 % gels with violet LED/laser has a greater increase in surface temperature compared to HP6 % gel, the different light systems do not significantly increase the intrapulpal temperature.

26 July 2024 in Lasers in Medical Science
Verified
Journal Article
Closed access
PDF file
MOMaria Gabriela Veiga Vidal de Oliveira
Maria Gabriela Veiga Vidal de Oliveira
DDDaniel José Braga Dutra
Daniel José Braga Dutra
JCJoatan Lucas De Sousa Gomes Costa
Joatan Lucas De Sousa Gomes Costa
JBJoão Felipe Besegato
João Felipe Besegato
ABAntonia Patricia Oliveira Barros
Antonia Patricia Oliveira Barros
HAHugo Henriques Alvim
Hugo Henriques Alvim

9 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LGLucas David Galvani
Lucas David Galvani
ABAntonia Patricia Oliveira Barros
Antonia Patricia Oliveira Barros
JCJoatan Lucas De Sousa Gomes Costa
Joatan Lucas De Sousa Gomes Costa
EOEliane Cristina Gulin de Oliveira
Eliane Cristina Gulin de Oliveira
Ester Alves Ferreira BordiniEster Alves Ferreira Bordini
Ester Alves Ferreira Bordini
Milton Carlos KugaMilton Carlos Kuga
Milton Carlos Kuga
The aim of this study was to evaluate the effects of mechanized final irrigation protocols (XPE, XP-Endo Finisher; XPC, XP-Clean; and ECL, Easy Clean) compared to PUI (passive ultrasonic irrigation) on the debris incidence and open dentinal tubules, and their effects on the adhesion interface after 48 h and 6 months. One hundred twenty maxillary central incisors were submitted to chemical–mechanical preparation using a rotary instrument and 2.5% sodium hypochlorite. Specimens were distributed in 4 groups (n = 30) in accordance with the mechanized final irrigation protocol: XPE, XPC, ECL, or PUI. Forty specimens (n = 10/group) were submitted to SEM analysis to evaluate the residue incidence and dentin open tubules. The other specimens were obturated using Bio-C Sealer and submitted to push-out bond strength and adhesive failure mode evaluations in the cervical, middle, and apical thirds after 48 h or 6 months (n = 10/group). Only in the apical third, ECL presented the highest residue incidence and fewer open dentinal tubules when compared to the XPE, XPC, and PUI groups (p < 0.05). In the cervical and middle root thirds, no significant differences were observed regardless of the group evaluated (p > 0.05). After 48 h, ECL resulted in the lowest bond strength only in the apical third (p < 0.05), while the XPE, XPC, and PUI groups remained similar in the cervical and middle thirds (p > 0.05). At 6 months, all groups showed lower bond strength values regardless of the root third evaluated, but ECL showed the lowest bond strength in the apical and middle root thirds when compared to the other groups (p < 0.05). The ECL protocol did not provide adequate residue removal on the apical radicular third and negatively affected the longevity of endodontic obturation using a calcium silicate-based sealer.