The significant and growing global prevalence of diabetes continues to challenge people with diabetes (PwD), healthcare providers, and payers. While maintaining near-normal glucose levels has been shown to prevent or delay the progression of the long-term complications of diabetes, a significant proportion of PwD are not attaining their glycemic goals. During the past 6 years, we have seen tremendous advances in automated insulin delivery (AID) technologies. Numerous randomized controlled trials and real-world studies have shown that the use of AID systems is safe and effective in helping PwD achieve their long-term glycemic goals while reducing hypoglycemia risk. Thus, AID systems have recently become an integral part of diabetes management. However, recommendations for using AID systems in clinical settings have been lacking. Such guided recommendations are critical for AID success and acceptance. All clinicians working with PwD need to become familiar with the available systems in order to eliminate disparities in diabetes quality of care. This report provides much-needed guidance for clinicians who are interested in utilizing AIDs and presents a comprehensive listing of the evidence payers should consider when determining eligibility criteria for AID insurance coverage.

5 December 2022 in Pediatric Diabetes
Verified
Journal Article
Closed access
JSJennifer L. Sherr
Jennifer L. Sherr
MSMelissa Schoelwer
Melissa Schoelwer
TSTiago Jeronimo Dos Santos
Tiago Jeronimo Dos Santos
LRLeenatha Reddy
Leenatha Reddy
TBTorben Biester
Torben Biester
LDLinda DiMeglio
Linda DiMeglio

1 February 2017 in The Journal of Pediatrics
Verified
Journal Article
Open access
TDThomas Danne
Thomas Danne
TBTorben Biester
Torben Biester
KKKerstin Kapitzke
Kerstin Kapitzke
SJSanja H. Jacobsen
Sanja H. Jacobsen
LJLisbeth V. Jacobsen
Lisbeth V. Jacobsen
OKOlga Kordonouri
Olga Kordonouri
To investigate the safety, tolerability, and pharmacokinetics of liraglutide in adolescents with obesity. This was a randomized, double-blind, placebo-controlled trial. Twenty-one subjects, aged 12-17 years and Tanner stage 2-5, with obesity (body mass index [BMI] corresponding to both a BMI ≥95th percentile for age and sex and to a BMI of ≥30 kg/m2 for adults; additionally, BMI was ≤45 kg/m2) were randomized (2:1) to receive 5 weeks of treatment with liraglutide (0.6 mg with weekly dose increase to a maximum of 3.0 mg for the last week) (n = 14) or placebo (n = 7). The primary endpoint was number of treatment-emergent adverse events (TEAEs). Secondary endpoints included safety measures, and pharmacokinetic and pharmacodynamic endpoints. All participants receiving liraglutide, and 4 receiving placebo (57.1%), had at least 1 TEAE. The most common TEAEs were gastrointestinal disorders. No severe TEAEs, TEAE-related withdrawals, or deaths occurred. Twelve hypoglycemic episodes occurred in 8 participants receiving liraglutide and 2 in 1 participant receiving placebo. No severe hypoglycemic episodes were reported. Liraglutide exposure in terms of trough concentration increased with dose, although dose proportionality was confounded by unexpectedly low trough concentration values at the 2.4 mg dose. Exposure in terms of model-derived area under the plasma concentration time curve from 0 to 24 hours after dose in steady state was similar to that in adults with obesity. Liraglutide had a similar safety and tolerability profile compared with adults when administered to adolescents with obesity, with no unexpected safety/tolerability issues. Results suggest that the dosing regimen approved for weight management in adults may be appropriate for use in adolescents. ClinicalTrials.gov: NCT01789086.

1 March 2017 in Diabetes Technology & Therapeutics
Verified
Journal Article
Open access
TBTorben Biester
Torben Biester
OKOlga Kordonouri
Olga Kordonouri
MHMartin Holder
Martin Holder
KRKerstin Remus
Kerstin Remus
DKDorothee Kieninger-Baum
Dorothee Kieninger-Baum
TDThomas Danne
Thomas Danne
Background: A sensor-augmented insulin pump (SAP) using the MiniMed ® 640G system with SmartGuard™ technology allows an automatic stop of insulin delivery based on prediction of low glucose levels. Since pediatric patients are particularly prone to hypoglycemia, this device may offer additional protection beyond conventional sensor-augmented therapy. Methods: This prospective, pediatric multicenter user evaluation assessed 6 weeks of SAP with SmartGuard (threshold setting for hypoglycemia: 70 mg/dL) compared to a preceding period of 2 weeks with SAP only. The primary outcome was the potential reduction in the frequency of hypoglycemic episodes and hypoglycemic intensity (area under the curve [AUC] and time <70 mg/dL). Results: The study included 24 patients with at least 3 months of insulin pump use (average age: 11.6 ± 5.1 years, 15 female, average type 1 diabetes duration: 7.5 ± 4.2 years, mean ± SD) who had on average 3.2 ± 1.0 predictive suspensions/patient/day. The mean sensor glucose minimum during suspension was 78 ± 6 mg/dL and the average suspension time was 155 ± 47 min/day. Use of SmartGuard in patients treated as per the protocol ( n = 18) reduced the number of instances in which the glucose level was <70 mg/dL (1.02 ± 0.52 to 0.72 ± 0.36; P = 0.027), as well as AUC <70 mg/dL (0.76 ± 0.73 to 0.38 ± 0.24; P = 0.027) and the time/day the level fell below 70 mg/dL (73 ± 56 to 31 ± 22 min). The reduction of hypoglycemia was not associated with a significant change in mean glucose concentration (171 ± 26 to 180 ± 19 mg/dL, P = 0.111) and HbA1c (7.5% ± 0.5% to 7.6% ± 0.7%, ( P = 0.329). Manual resumption of insulin delivery followed by carbohydrate intake resulted in significantly higher glucose levels 1 h after suspension compared to SmartGuard suspensions with automatic resume (190.8 ± 26.5 vs. 138.7 ± 10.3 mg/dL; P < 0.001). Conclusions: SmartGuard technology significantly reduced the risk for hypoglycemia in pediatric type 1 diabetes patients without increasing HbA1c. Patients must be educated that when using combining predictive low-glucose insulin suspension technology, extra carbohydrate intake in response to an alarm combined with manual resumption is likely to cause rebound hyperglycemia. The best results were achieved when the user did not interfere with pump operation.

10 December 2024 in Hormone Research in Paediatrics
Verified
Journal Article
Open access
TBTorben Biester
Torben Biester
CBCari Berget
Cari Berget
CBCharlotte Boughton
Charlotte Boughton
LCLaura Cudizio
Laura Cudizio
LELaya Ekhlaspour
Laya Ekhlaspour
KDKlemen Dovč
Klemen Dovč
The International Society for Pediatric and Adolescent Diabetes (ISPAD) guidelines represent a rich repository that serves as the only comprehensive set of clinical recommendations for children, adolescents, and young adults living with diabetes worldwide. This chapter builds on the 2022 ISPAD guidelines, and summarizes recent advances in the technology behind insulin administration, with special emphasis on insulin pump therapy, especially on glucose-responsive integrated technology that is feasible with the use of automated insulin delivery (AID) systems in children and adolescents.

28 July 2018 in Pediatric Diabetes
Verified
Journal Article
Open access
PDF file
FCFiona M. Campbell
Fiona M. Campbell
NMNuala P. Murphy
Nuala P. Murphy
CSCaroline Stewart
Caroline Stewart
TBTorben Biester
Torben Biester
OKOlga Kordonouri
Olga Kordonouri
Background and objective Outcomes of using flash glucose monitoring have been reported in adults. This trial evaluated use in children and teenagers with type 1 diabetes. Methods Prospective, single arm, non‐inferiority multi‐center study to demonstrate equivalence of time in range (TIR [70‐180mg/dL]) by comparing 14‐day masked sensor wear (baseline) with self‐monitored blood glucose (SMBG) testing to the final 14‐days of 8‐week open‐label system use for diabetes self‐management including insulin dosing. Results 76 children and teenagers (46.1% male; age 10.3±4.0 years, type 1 diabetes duration 5.4±3.7 years; mean±SD) from 10 sites participated. TIR improved significantly by 0.9±2.8 hrs/day (p=0.005) versus SMBG baseline. Time in hyperglycemia (>180 mg/dL) reduced by ‐1.2±3.3 hours/day (p=0.004). HbA1c reduced by ‐0.4% (4.4mmol/mol), from 7.9±1.0% (62.9±11.2mmol/mol) baseline to 7.5±0.9% (58.5±9.8mmol/mol) study end, (p<0.0001) with reductions across all age‐subgroups (4‐6, 7‐12, and 13‐17 years). Time in hypoglycemia (<70 mg/dL) was unaffected. Throughout the treatment phase system utilization was 91±9%; sensor scanning was 12.9±5.7/ day with SMBG dropping to 1.6±1.9 from 7.7±2.5/day. Diabetes Treatment Satisfaction Questionnaire ‘Total Treatment Satisfaction’ score improved for parents (p<0.0001) and teenagers (p<0.0001). No adverse events (n=121) were associated with sensor accuracy, 42 participants experienced sensor insertion signs and symptoms. Three participants experienced 3 mild device‐related (sensor wear) symptoms, resolving quickly (without treatment [n=2], non‐prescription antihistamines [n=1]). Conclusions Children with diabetes improved glycemic control safely and effectively with short term flash glucose monitoring use compared within arm, to use of SMBG.