Giuseppe Tumminello

Giuseppe Tumminello


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
ARAnna Maria Roszkowska
Anna Maria Roszkowska
GTGiuseppe Tumminello
Giuseppe Tumminello
CLCarmelo Licitra
Carmelo Licitra
ASAlice Antonella Severo
Alice Antonella Severo
LILeandro Inferrera
Leandro Inferrera
PAPasquale Aragona
Pasquale Aragona
Background: To examine the 12-month clinical and refractive outcomes of PRK performed with a UV all-solid-state laser. Methods: The study included healthy patients with myopia and/or compound myopic astigmatism enrolled for refractive surgery and treated with PRK using a 210 nm wavelength, 2 kHz repetition rate, UV all-solid-state laser (LaserSoft, Katana Technologies GmbH, Kleinmachnow, Germany). All subjects were examined at baseline and after 1, 3, 6, and 12 months after the treatment with a slit lamp, refraction, visual acuity assessment (logMAR chart), tonometry, ophthalmoscopy, and corneal tomography with a Scheimpflug camera. The outcome measures considered were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, central corneal thickness, and transparency. The efficacy, safety, predictability, and stability were determined. Results: The study included 34 eyes of 19 patients. The mean UDVA changed from 1.20 ± 0.43 to −0.05 ± 0.10 logMAR at 12 months, and the mean CDVA changed from −0.03 ± 0.06 to −0.06 ± 0.09 logMAR, respectively. The mean spherical equivalent (SE) changed from −4.90 ± 2.12 D to −0.01 ± 0.40 D and was within ±0.50 D of the intended correction in 91% of eyes and within ±1.00 D in 97% of eyes at 12 months. No eyes lost lines of visual acuity, and 64% of eyes gained one or more lines. Conclusions: PRK with the 210 nm wavelength, 2 kHz repetition rate, all-solid-state laser LaserSoft system proved to have good visual, refractive, and clinical outcomes after the follow-up at 12 months. The emerging gas-free, solid-state technology might be considered a valid alternative for the gas operating lasers for corneal refractive surgery.

Verified
Journal Article
Open access
PDF file
GGGregorio Lo Giudice
Gregorio Lo Giudice
GMGiuseppe Miceli
Giuseppe Miceli
GTGiuseppe Tumminello
Giuseppe Tumminello
ATAlessandro Trapani
Alessandro Trapani
APAntonino Pioppo
Antonino Pioppo
Purpose: To describe the efficacy and safety of surgical treatment in refractory glaucoma using transscleral cyclophotocoagulation with a diode laser (TSCPC). Cyclo-G6 laser with a G-probe delivery system (Iridex, Silicon Valley, CA, USA). Materials and Methods: 134 patients (134 eyes) with refractory glaucoma were included in this study. Patients received transscleral cyclophotocoagulation (TSCPC) using the IRIDEX Cyclo-G6 diode laser equipped with a G-probe delivery system. The eyes were treated with 1250–1500 mW for 3500–4000 ms depending on the iris colour. Intraocular pressure (IOP) and the count of antiglaucoma medications (AGM) were documented at the initial assessment and again at 3, 6, and 12 months following the treatment. Results: A reduction in IOP was observed in 97.73% of eyes at 12 months. At 12 months, 55.97% of the 134 eyes decreased IOP under 21 mmHg. At the 3-month mark, 96.27% of eyes attained an IOP reduction in 30% or more from their initial baseline levels, 85.61% at 6 months, and 82.17% at 12 months. A reduction in AGM was recorded for 86.07% of patients at 6 months and 87.31% at 12 months. There were no instances of severe complications reported, and minor complications were observed in 3% (4 out of 134) of the treated eyes. Conclusions: IRIDEX Cyclo-G6 laser is a surgical method effective in reducing IOP in patients with refractory glaucoma