We present a review of the published experimental and simulation radiation damage results in Ga 2 O 3 . All of the polytypes of Ga 2 O 3 are expected to show similar radiation resistance as GaN and SiC, considering their average bond strengths. However, this is not enough to explain the orders of magnitude difference of the relative resistance to radiation damage of these materials compared to GaAs and dynamic annealing of defects is much more effective in Ga 2 O 3 . It is important to examine the effect of all types of radiation, given that Ga 2 O 3 devices will potentially be deployed both in space and terrestrial applications. Octahedral gallium monovacancies are the main defects produced under most radiation conditions because of the larger cross-section for interaction compared to oxygen vacancies. Proton irradiation introduces two main paramagnetic defects in Ga 2 O 3 , which are stable at room temperature. Charge carrier removal can be explained by Fermi-level pinning far from the conduction band minimum due to gallium interstitials (Ga i ), vacancies (V Ga ), and antisites (Ga O ). One of the most important parameters to establish is the carrier removal rate for each type of radiation, since this directly impacts the current in devices such as transistors or rectifiers. When compared to the displacement damage predicted by the Stopping and Range of Ions in Matter(SRIM) code, the carrier removal rates are generally much lower and take into account the electrical nature of the defects created. With few experimental or simulation studies on single event effects (SEE) in Ga 2 O 3 , it is apparent that while other wide bandgap semiconductors like SiC and GaN are robust against displacement damage and total ionizing dose, they display significant vulnerability to single event effects at high Linear Energy Transfer (LET) and at much lower biases than expected. We have analyzed the transient response of β -Ga 2 O 3 rectifiers to heavy-ion strikes via TCAD simulations. Using field metal rings improves the breakdown voltage and biasing those rings can help control the breakdown voltage. Such biased rings help in the removal of the charge deposited by the ion strike.
Electron beam-induced current in the temperature range from 304 to 404 K was employed to measure the minority carrier diffusion length in metal–organic chemical vapor deposition-grown p-Ga2O3 thin films with two different concentrations of majority carriers. The diffusion length of electrons exhibited a decrease with increasing temperature. In addition, the cathodoluminescence emission spectrum identified optical signatures of the acceptor levels associated with the VGa−–VO++ complex. The activation energies for the diffusion length decrease and quenching of cathodoluminescence emission with increasing temperature were ascribed to the thermal de-trapping of electrons from VGa−–VO++ defect complexes.
Highly resistive undoped p-type gallium oxide samples were subjected to cumulative proton irradiation with energies ranging from 25 to 70 keV and doses in the 1.6 × 1014–3.6 × 1014 cm−2 range. Proton irradiation resulted in up to a factor of 2 reduction of minority electron diffusion length in the samples for temperatures between ∼ 300 and 400 K. Electron injection into the samples under test using a scanning electron microscope beam leads to pronounced elongation of diffusion length beyond the pre-irradiation values, thus demonstrating stable (days after injection) recovery of adverse radiation impact on minority carrier transport. The activation energy of 91 meV estimated from the temperature dependent diffusion length vs electron injection duration experiments is likely related to the local potential barrier height for native defects associated with the phenomenon of interest.
5 January 2020 in ECS Journal of Solid State Science and Technology
We report the effect of extended duration electron beam exposure on the minority carrier transport properties of 10 MeV proton irradiated (fluence ∼1014 cm−2) Si-doped β-Ga2O3 Schottky rectifiers. The diffusion length (L) of minority carriers is found to decrease with temperature from 330 nm at 21 °C to 289 nm at 120 °C, with an activation energy of ∼26 meV. This energy corresponds to the presence of shallow Si trap-levels. Extended duration electron beam exposure enhances L from 330 nm to 726 nm at room temperature. The rate of increase for L is lower with increased temperature, with an activation energy of 43 meV. Finally, a brief comparison of the effect of electron injection on proton irradiated, alpha-particle irradiated and a reference Si-doped β-Ga2O3 Schottky rectifiers is presented.
Minority hole diffusion length and lifetime were measured in independent experiments by electron beam-induced current and time-resolved cathodoluminescence in Si-doped β-Ga2O3 Schottky rectifiers irradiated with 18 MeV alpha particles and 10 MeV protons. Both diffusion length and lifetime exhibited a decrease with increasing temperature. The non-equilibrium minority hole mobility was calculated from the independently measured diffusion length and lifetime, indicating that the so-called hole self-trapping is most likely irrelevant in the 77–295 K temperature range.
The impact of electron injection on minority carrier (hole) diffusion length and lifetime at variable temperatures was studied using electron beam-induced current, continuous, and time-resolved cathodoluminescence techniques. The hole diffusion length increased from 306 nm to 347 nm with an electron injection charge density up to 117.5 nC/μm3, corresponding to the lifetime changing from 77 ps to 101 ps. Elongation of the diffusion length was attributed to the increase in the non-equilibrium carrier lifetime, which was determined using ultrafast time-resolved cathodoluminescence and related to non-equilibrium carrier trapping on gallium vacancy levels in the GaN forbidden gap.