Virtual synchronous generator (VSG) is an important concept toward frequency stabilisation of the modern power system. The penetration of power electronic‐based power generation in power grid reduces the total inertia, and thus increases the risk of frequency instability when disturbance occurs in the grid. VSG produces virtual inertia by injecting appropriate active power value to the grid when needed. This virtual inertia can stabilise the grid frequency in case of a power imbalance between generation and loads or any disturbances that affected frequency stability. Its intensive research can see the importance of VSG in inertia control and various intelligent controller techniques. Owing to the importance of VSG in the modern power grid, this study provides a comprehensive review on the control and coordination of VSG toward grid stabilisation in terms of frequency, voltage and oscillation damping during inertia response. A review on the type of energy storage system used for VSG and their benefits is also presented. Finally, perspective on the technical challenges and potential future research related to VSG is also discussed in this study.
This paper investigates the possibility of using Dynamic Line Rating (DLR) to increase the existing power transmission capacity of overhead lines. The main contribution is to combine theoretical calculations and modeling with real application to conclude benefits of DLR. Both introduction of relevant theory and a case study on a power distribution system in Sweden are included. The concept of DLR implies that the capacity of a component dynamically varies as a function of external parameters, such as weather conditions and loading history. Traditionally, the rating is statically set from simulations of worst-case scenarios. Based on conventional static line rating (SLR) methods, the actual current carrying capability of overhead conductors is underestimated. When an increase in the line current capacity is needed, overhead lines may be rated based on a method that allows system operators to run the lines closer to their actual real-time capacity. Furthermore, the paper addresses the problems of observing safe ground clearance requirements. Knowing the conductor temperature, when it transmits the required electricity is an important factor to be taken into consideration. Therefore, based on real-time ambient conditions with actual line loading and with the help of IEEE-738-2006 standard, the conductor temperature is also calculated in this paper. Finally, an economic analysis is performed to evaluate the financial advantages of applying the dynamic line ratings approach compared to traditional static line ratings technique for a specific overhead conductor (VL3).
1 December 2019 in Electric Power Systems Research
Dynamic line rating is a novel technique used to determine the actual value of available power transmission capacity of overhead lines being underestimated by static line rating. Contrary to static line rating method, this approach provides huge technical and economic benefits of transmitting the electrical energy under controlled constraints. Nevertheless, it is of utmost importance to have an accurate knowledge of dynamic ampacity before being practically implemented. Owing to dynamic line rating technique, an overhead conductor is rated on the basis of real-time ampacity. Furthermore, the real time ampacity contributes in combating the growing power transmission demand being observed over highly congested power transmission network. Contrary to dynamic line rating approach, building new overhead lines is a lengthy, expensive, and less reliable option. Another important advantage offered by the dynamic line rating approach is to allow excessive renewable power generation in the electricity network, particularly the wind power due to its correlation with real-time ampacity. Besides, dynamic ampacity and wind power integration, the paper also deals with risk analysis associated with conductor overloading. The risk involves increase in conductor sag as it transmits the power beyond its nominal capacity at a certain temperature. However, in this paper, the dynamic as well as the static ampacity of “VL3” overhead conductor is calculated on the basis of its nominal temperature (50 °C) to avoid the risk of its possible expansion and ultimately the deterioration. In addition to technical analysis, the economic analysis of integrating a 60 MW wind park with Fortum's 130 kV regional grid and of applying dynamic line rating approach on a periodically overloaded “VL3” overhead conductor is thoroughly investigated in this research work; to further know how beneficial it is to temporarily postpone the rebuilding and/or construction of a new overhead line in parallel to the existing overhead conductor (VL3).