Joaquín Pedra

Dr. Joaquín Pedra

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
Lluis MonjoLluis Monjo
Lluis Monjo
Luis Sainz-SaperaLuis Sainz-Sapera
Luis Sainz-Sapera
JMJuan José Mesas
Juan José Mesas
JPJoaquín Pedra
Joaquín Pedra
Quasi-Z-source inverters (qZSIs) are becoming a powerful power conversion technology in photovoltaic (PV) power systems because they allow energy power conversion in a single stage operation. However, they can cause system resonances and reduce system damping, which may lead to instabilities. These stability problems are well known in grid-connected voltage source converter systems but not in quasi-Z-source inverter (qZSI)-based PV power systems. This paper contributes with Matlab/Simulink and PSCAD/EMTDC models of qZSI-based PV power systems to analyze transient interactions and stability problems. These models consider all power circuits and control blocks of qZSI-based PV power systems and can be used in sensitivity studies on the influence of system parameters on stability. PV power system stability is assessed from the proposed models. The causes of instabilities are analyzed from numerical simulations and possible solutions are proposed.

6 February 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JPJoaquín Pedra
Joaquín Pedra
Luis Sainz-SaperaLuis Sainz-Sapera
Luis Sainz-Sapera
Lluis MonjoLluis Monjo
Lluis Monjo
Impedance/admittance transfer matrix characterization of voltage source converters is an essential issue in frequency domain stability studies. Several dq - and pn -frame approaches are proposed to obtain this matrix with experimental or numerical simulation measurements. Although these are well-established approaches, various issues require further study. The paper presents a detailed review and discussion on the dq - and pn -frame approaches for converter impedance/admittance transfer matrix measurements and contributes to clarifying the influence of the mirror frequency effect and the starting point of the FFT window on these measurements. The contributions are validated by PSCAD/EMTDC simulation with a VSC model containing PLL and outer controls.

9 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
Lluis MonjoLluis Monjo
Lluis Monjo
Luis Sainz-SaperaLuis Sainz-Sapera
Luis Sainz-Sapera
JMJuan José Mesas
Juan José Mesas
JPJoaquín Pedra
Joaquín Pedra
Photovoltaic (PV) power systems are increasingly being used as renewable power generation sources. Quasi-Z-source inverters (qZSI) are a recent, high-potential technology that can be used to integrate PV power systems into AC networks. Simultaneously, concerns regarding the stability of PV power systems are increasing. Converters reduce the damping of grid-connected converter systems, leading to instability. Several studies have analyzed the stability and dynamics of qZSI, although the characterization of qZSI-PV system dynamics in order to study transient interactions and stability has not yet been properly completed. This paper contributes a small-signal, state-space-averaged model of qZSI-PV systems in order to study these issues. The model is also applied to investigate the stability of PV power systems by analyzing the influence of system parameters. Moreover, solutions to mitigate the instabilities are proposed and the stability is verified using PSCAD time domain simulations.

6 September 2012 in IET Electric Power Applications
Verified
Journal Article
Closed access
ARA. Rolán
A. Rolán
FCF. CórColes
F. CórColes
JPJoaquín Pedra
Joaquín Pedra
This study analyses the dynamic behaviour of the doubly fed induction generator exposed to unsymmetrical voltage sags, providing insights into wind turbine fault ride-through capability. The sags are assumed to be caused by faults. An analytical approach assuming that the rotor-side converter can keep constant the rotor current in the synchronous reference frame during the event is used. The voltage limit of the rotor-side converter is also considered in order to determine the situations where the rotor current can be controlled. The effects of sags on grid-connected equipments depend on the sag characteristics (duration and depth), but also on the fault clearing process. In this process, the fault is not cleared instantaneously, as in the case of abrupt sags (which is the usual approach in the literature), but in the successive natural fault-current zeros, leading to a voltage recovery in several steps known as discrete sags. The effects of both abrupt and discrete sags on the doubly fed induction generator behaviour are compared. This comparison reveals that the discrete clearing process smoothes the sag effects on the generator.

26 September 2022 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
JPJoaquín Pedra
Joaquín Pedra
LSL. Sainz
L. Sainz
Lluis MonjoLluis Monjo
Lluis Monjo

11 April 2024 in Energies
Verified
Journal Article
Open access
PDF file
JPJoaquín Pedra
Joaquín Pedra
Luis Sainz-SaperaLuis Sainz-Sapera
Luis Sainz-Sapera
Lluis MonjoLluis Monjo
Lluis Monjo
This work deals with doubly fed induction generator (DFIG) modeling and stability when connected to weak AC grids. A detailed state-space model that includes the phase-locked loop (PLL) is developed. This work aims to determine the influence of the network’s strength on DFIG stability through the short-circuit ratio (SCR). The critical values of the proportional control parameters of the grid-side and rotor-side converters (RSC and GSC), as well as PLL, which make the system unstable, are calculated for different SCR values. Finally, PSCAD/EMTDC dynamic simulations are used to validate the critical control parameters obtained by studying the eigenvalues of the DFIG state-space model regarding system stability.