Robert Elkington

Mr. Robert Elkington

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
RERobert Elkington
Robert Elkington
RHRichard M. Hall
Richard M. Hall
ABAndrew R. Beadling
Andrew R. Beadling
HPHemant Pandit
Hemant Pandit
MBMichael G. Bryant
Michael G. Bryant
To enable long lasting osteochondral defect repairs which preserve the native function of synovial joint counter-face, it is essential to develop surfaces which are optimised to support healthy cartilage function by providing a hydrated, low friction and compliant sliding interface. PEEK surfaces were modified using a biocompatible 3-sulfopropyl methacrylate potassium salt (SPMK) through UV photo-polymerisation, resulting in a ∼350 nm thick hydrophilic coating rich in hydrophilic anionic sulfonic acid groups. Characterisation was done through Fourier Transformed Infrared Spectroscopy, Focused Ion Beam Scanning Electron Microscopy, and Water Contact Angle measurements. Using a Bruker UMT TriboLab, bovine cartilage sliding tests were conducted with real-time strain and shear force measurements, comparing untreated PEEK, SPMK functionalised PEEK (SPMK-g-PEEK), and Cobalt Chrome Molybdenum alloy. Tribological tests over 2.5 h at physiological loads (0.75 MPa) revealed that SPMK-g-PEEK maintains low friction (μ< 0.024) and minimises equilibrium strain, significantly reducing forces on the cartilage interface. Post-test analysis showed no notable damage to the cartilage interfacing against the SPMK functionalised surfaces. The application of a constitutive biphasic cartilage model to the experimental strain data reveals that SPMK surfaces increase the interfacial permeability of cartilage in sliding, facilitating fluid and strain recovery. Unlike previous demonstrations of sliding-induced tribological rehydration requiring specific hydrodynamic conditions, the SPMK-g-PEEK introduces a novel mode of tribological rehydration operating at low speeds and in a stationary contact area. SPMK-g-PEEK surfaces provide an enhanced cartilage counter-surface, which provides a highly hydrated and lubricious boundary layer along with supporting biphasic lubrication. Soft polymer surface functionalisation of orthopaedic implant surfaces are a promising approach for minimally invasive synovial joint repair with an enhanced bioinspired polyelectrolyte interface for sliding against cartilage. These hydrophilic surface coatings offer an enabling technology for the next generation of focal cartilage repair and hemiarthroplasty implant surfaces.

7 May 2024 in Langmuir
Verified
Journal Article
Open access
RERobert Elkington
Robert Elkington
RHRichard M. Hall
Richard M. Hall
ABAndrew R. Beadling
Andrew R. Beadling
HPHemant Pandit
Hemant Pandit
MBMichael Bryant
Michael Bryant
This study presents new insights into the potential role of polyelectrolyte interfaces in regulating low friction and interstitial fluid pressurization of cartilage. Polymer brushes composed of hydrophilic 3-sulfopropyl methacrylate potassium salt (SPMK) tethered to a PEEK substrate (SPMK-g-PEEK) are a compelling biomimetic solution for interfacing with cartilage, inspired by the natural lubricating biopolyelectrolyte constituents of synovial fluid. These SPMK-g-PEEK surfaces exhibit a hydrated compliant layer approximately 5 μm thick, demonstrating the ability to maintain low friction coefficients (μ ∼ 0.01) across a wide speed range (0.1-200 mm/s) under physiological loads (0.75-1.2 MPa). A novel polyelectrolyte-enhanced tribological rehydration mechanism is elucidated, capable of recovering up to ∼12% cartilage strain and subsequently facilitating cartilage interstitial fluid recovery, under loads ranging from 0.25 to 2.21 MPa. This is attributed to the combined effects of fluid confinement within the contact gap and the enhanced elastohydrodynamic behavior of polymer brushes. Contrary to conventional theories that emphasize interstitial fluid pressurization in regulating cartilage lubrication, this work demonstrates that SPMK-g-PEEK's frictional behavior with cartilage is independent of these factors and provides unabating aqueous lubrication. Polyelectrolyte-enhanced tribological rehydration can occur within a static contact area and operates independently of known mechanisms of cartilage interstitial fluid recovery established for converging or migrating cartilage contacts. These findings challenge existing paradigms, proposing a novel polyelectrolyte-cartilage tribological mechanism not exclusively reliant on interstitial fluid pressurization or cartilage contact geometry. The implications of this research extend to a broader understanding of synovial joint lubrication, offering insights into the development of joint replacement materials that more accurately replicate the natural functionality of cartilage.

24 May 2024 in Tribology International
Verified
Journal Article
Open access
RERobert Elkington
Robert Elkington
RHRichard M. Hall
Richard M. Hall
ABAndrew R. Beadling
Andrew R. Beadling
HPHemant G. Pandit
Hemant G. Pandit
MBMichael G. Bryant
Michael G. Bryant

13 March 2025 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
RERobert Elkington
Robert Elkington
GPGregory M. Pryce
Gregory M. Pryce
DKDavid Keeling
David Keeling
RHRichard M. Hall
Richard M. Hall
ABAndrew R. Beadling
Andrew R. Beadling
Michael BryantMichael Bryant
Michael Bryant
Effective fluid exudation and rehydration are essential for the low-friction function of healthy articular cartilage, facilitating interstitial fluid pressurisation, solute transport, and aqueous lubrication. However, current metallic biomaterials used in focal cartilage repair or hemiarthroplasty compromise this fluid-pressure dependent load support, leading to the erosion of the interfacing cartilage. This study investigates bioinspired hydrophilic 3-sulfopropyl methacrylate potassium salt (SPMK) polymer grafted onto a PEEK substrate (SPMK-g-PEEK) as a potential solution. SPMK-g-PEEK aims to mimic the natural tribology of cartilage by providing an aqueous low friction interface and polyelectrolyte-enhanced tribological rehydration (PETR), supporting fluid recovery and interstitial fluid pressurisation during cartilage sliding. We compare the tribological characteristics of physiological cartilage-cartilage interfaces, which rely on osmotic swelling and hydrodynamic tribological rehydration, with PETR enabled by SPMK-g-PEEK interfaces. This study introduces a bespoke Fuzzy-PI controlled biotribometer. Employing a dual-phase testing method, static compression followed by sliding, allows simultaneous measurement of friction and cartilage strain recovery, indicative of interstitial fluid recovery following compressive exudation. Cartilage condyle, unfunctionalised PEEK, and SPMK-g-PEEK surfaces were investigated against flat cartilage plugs, which provide no hydrodynamic entrainment zone for tribological rehydration, and convex cartilage plugs, which create a convergent hydrodynamic zone for tribological rehydration. Matched cartilage-cartilage contacts exhibited low friction coefficients of ∼ 0.04 and strain recovery of up to ∼ 14% during the sliding phase. SPMK-g-PEEK surfaces sliding against convex cartilage plugs demonstrated similar strain recovery of ∼ 13% and reduced friction coefficients of ∼ 0.01, due to the combined effects of PETR and hydrodynamic tribological rehydration. In contrast, unfunctionalised PEEK surfaces, similar to current hard biomaterials employed in cartilage resurfacing, showed significantly higher friction and inhibited rehydration. SPMK-g-PEEK effectively mimics the physiological rehydration of connatural articular cartilage surfaces, highlighting its potential as a biomimetic material for cartilage resurfacing.

13 September 2024 in Sports Engineering
Verified
Journal Article
Open access
PDF file
RERobert Elkington
Robert Elkington
JAJosh L. Armitage
Josh L. Armitage
TKThawhid Khan
Thawhid Khan
MBMichael G. Bryant
Michael G. Bryant
This study examines the tribological properties of climbing shoe rubbers, challenging the common belief in the climbing community that softer rubbers are inherently grippier. This study investigates the mechanical and wear characteristics of climbing shoe rubbers by employing a high-precision modular mechanical testing environment (Bruker UMT TriboLab) and representative granite counter-surfaces. Key parameters, including surface roughness, Shore A hardness, interfacial adhesion, static and dynamic friction coefficients, and material wear patterns, were analyzed. The mechanical properties of each rubber compound were characterized through Shore A hardness testing and ball indentation–retraction tests, measuring indentation force, energy, and adhesive properties. Sliding friction tests, simulating real climbing conditions, were conducted to understand the tribological behavior of each rubber compound under different loads, further analyzing static and dynamic friction coefficients and wear characteristics. The findings of this study indicate that rubber performance is a convolution of several factors, including material hardness, surface roughness, and interfacial adhesion. Contrary to popular belief, softer rubbers did not consistently exhibit superior tribological characteristics. The findings of this study suggest that climbing shoe selection and design should consider a broader range of material characteristics beyond hardness, emphasizing the role of surface roughness and adhesion in determining overall frictional performance. This research offers valuable insights for the climbing community, providing methodologies to benchmark climbing rubber material characteristics.