Michael Bryant

Prof. Dr. Michael Bryant


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Manoj Rajankunte MahadeshwaraManoj Rajankunte Mahadeshwara
Manoj Rajankunte Mahadeshwara
MAMaisoon Al-Jawad
Maisoon Al-Jawad
Richard mark HallRichard mark Hall
Richard mark Hall
HPHemant G. Pandit
Hemant G. Pandit
REReem El-Gendy
Reem El-Gendy
Michael BryantMichael Bryant
Michael Bryant
Cartilage degeneration is a characteristic of osteoarthritis (OA), which is often observed in aging populations. This degeneration is due to the breakdown of articular cartilage (AC) mechanical and tribological properties primarily attributed to lubrication failure. Understanding the reasons behind these failures and identifying potential solutions could have significant economic and societal implications, ultimately enhancing quality of life. This review provides an overview of developments in the field of AC, focusing on its mechanical and tribological properties. The emphasis is on the role of lubrication in degraded AC, offering insights into its structure and function relationship. Further, it explores the fundamental connection between AC mechano-tribological properties and the advancement of its degradation and puts forth recommendations for strategies to boost its lubrication efficiency.

16 June 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
BCBenjamin Clegg
Benjamin Clegg
SPSamuel Perry
Samuel Perry
EPEnrico De Pieri
Enrico De Pieri
ARAnthony C Redmond
Anthony C Redmond
SFStephen John Ferguson
Stephen John Ferguson
Andrew Robert BeadlingAndrew Robert Beadling
Andrew Robert Beadling
The current pre-clinical testing standards for total hip replacements (THRs), ISO standards, use simplified loading waveforms that do not fully replicate real-world biomechanics. These standards provide a benchmark of data that may not accurately predict in vivo wear, necessitating the evaluation of physiologically relevant loading conditions. Previous studies have incorporated activities of daily living (ADLs) such as walking, jogging and stair negotiation into wear simulations. However, these studies primarily used simplified adaptations that increased axial forces and applied accelerated sinusoidal waveforms, rather than fully replicating the complex kinematics experienced by THR patients. To address this gap, this study applied patient-derived ADL profiles—jogging and stair negotiation—using a three-station hip simulator, obtained through 3D motion analysis of total hip arthroplasty patients, processed via a musculoskeletal multibody modelling approach to derive realistic hip contact forces (HCFs). The results indicate that jogging significantly increased wear rates compared to the ISO walking gait waveform, with wear increasing from 15.24 ± 0.55 to 28.68 ± 0.87 mm3/Mc. Additionally, wear was highly sensitive to changes in lubricant protein concentration, with an increase from 17 g/L to 30 g/L reducing wear by over 60%. Contrary to predictive models, stair descent resulted in higher volumetric wear (8.62 ± 0.43 mm3/0.5 Mc) compared to stair ascent (4.15 ± 0.31 mm3/0.5 Mc), despite both profiles having similar peak torques. These findings underscore the limitations of current ISO standards in replicating physiologically relevant wear patterns. The application of patient-specific loading profiles highlights the need to integrate ADLs into pre-clinical testing protocols, ensuring a more accurate assessment of implant performance and longevity.

13 March 2025 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
RERobert Elkington
Robert Elkington
GPGregory M. Pryce
Gregory M. Pryce
DKDavid Keeling
David Keeling
RHRichard M. Hall
Richard M. Hall
ABAndrew R. Beadling
Andrew R. Beadling
Michael BryantMichael Bryant
Michael Bryant
Effective fluid exudation and rehydration are essential for the low-friction function of healthy articular cartilage, facilitating interstitial fluid pressurisation, solute transport, and aqueous lubrication. However, current metallic biomaterials used in focal cartilage repair or hemiarthroplasty compromise this fluid-pressure dependent load support, leading to the erosion of the interfacing cartilage. This study investigates bioinspired hydrophilic 3-sulfopropyl methacrylate potassium salt (SPMK) polymer grafted onto a PEEK substrate (SPMK-g-PEEK) as a potential solution. SPMK-g-PEEK aims to mimic the natural tribology of cartilage by providing an aqueous low friction interface and polyelectrolyte-enhanced tribological rehydration (PETR), supporting fluid recovery and interstitial fluid pressurisation during cartilage sliding. We compare the tribological characteristics of physiological cartilage-cartilage interfaces, which rely on osmotic swelling and hydrodynamic tribological rehydration, with PETR enabled by SPMK-g-PEEK interfaces. This study introduces a bespoke Fuzzy-PI controlled biotribometer. Employing a dual-phase testing method, static compression followed by sliding, allows simultaneous measurement of friction and cartilage strain recovery, indicative of interstitial fluid recovery following compressive exudation. Cartilage condyle, unfunctionalised PEEK, and SPMK-g-PEEK surfaces were investigated against flat cartilage plugs, which provide no hydrodynamic entrainment zone for tribological rehydration, and convex cartilage plugs, which create a convergent hydrodynamic zone for tribological rehydration. Matched cartilage-cartilage contacts exhibited low friction coefficients of ∼ 0.04 and strain recovery of up to ∼ 14% during the sliding phase. SPMK-g-PEEK surfaces sliding against convex cartilage plugs demonstrated similar strain recovery of ∼ 13% and reduced friction coefficients of ∼ 0.01, due to the combined effects of PETR and hydrodynamic tribological rehydration. In contrast, unfunctionalised PEEK surfaces, similar to current hard biomaterials employed in cartilage resurfacing, showed significantly higher friction and inhibited rehydration. SPMK-g-PEEK effectively mimics the physiological rehydration of connatural articular cartilage surfaces, highlighting its potential as a biomimetic material for cartilage resurfacing.

30 August 2024 in Lubricants
Verified
Journal Article
Open access
PDF file
JMJoshua Montgomery
Joshua Montgomery
CHCamille Hammersley
Camille Hammersley
MWMark Wilson
Mark Wilson
Michael BryantMichael Bryant
Michael Bryant
Gregory de BoerGregory de Boer
Gregory de Boer
Lubrication modeling has long been dominated by the well-established Patir and Cheng flow factors method. The flow factors approach allows for accurate estimates of macroscale parameters (such as friction) in a reasonable amount of time. These methods are stochastic representations of microscale interactions and are not able to predict local scale (pressure, film thickness) phenomena with a suitable degree of accuracy. This contrasts with a deterministic approach, where a numerical grid must be applied that fully defines the microscale surface topography across the contact. The mesh resolution required leads to prohibitively long execution times and lacks scalability to engineering systems, but provides accurate predictions of local scale phenomena. In this paper, heterogeneous multiscale methods (HMM) are expanded to model varying and are, therefore, more representative of surface topography within lubricated contacts. This representative topography is derived from measured data, thereby allowing the accuracy of deterministic methods to be achieved with the speed of a flow factor method. This framework is then applied to compare key performance characteristics (pressure, film thickness, etc.) when idealized, Gaussian, and measured surface topography are modeled. The variations in microscale geometry are defined by measurements from across two tilted-pad bearings, demonstrating the ability of the expanded HMM framework to model representative surface topography. A comparison with a deterministic method is included as validation, and outputs of the HMM are discussed in the context of the lubrication across multiple length scales.

11 April 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Manoj Rajankunte MahadeshwaraManoj Rajankunte Mahadeshwara
Manoj Rajankunte Mahadeshwara
MAMaisoon Al-Jawad
Maisoon Al-Jawad
Richard mark HallRichard mark Hall
Richard mark Hall
HPHemant G. Pandit
Hemant G. Pandit
REReem El-Gendy
Reem El-Gendy
Michael BryantMichael Bryant
Michael Bryant
Cartilage degeneration is a characteristic of osteoarthritis (OA) which is often observed in aging populations. This degeneration is due to the breakdown of articular cartilage (AC) mechanical and tribological properties, primarily attributed to lubrication failure. Understanding the reasons behind these failures and identifying potential solutions could have significant economic and societal implications, ultimately enhancing the quality of life. This review provides an overview of developments in the field of AC, focusing on its mechanical and tribological properties. The emphasis is on the role of lubrication in degraded AC, offering insights into its structure and function relationship. Further it explores the fundamental connection between AC mechano-tribological properties and the advancement of its degradation and puts forth recommendations for strategies to boost its lubrication efficiency.

4 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
AWAbigail Wade
Abigail Wade
Andrew Robert BeadlingAndrew Robert Beadling
Andrew Robert Beadling
DJDominic Jones
Dominic Jones
DVde Villiers de Villiers
de Villiers de Villiers
JCJo Cullum
Jo Cullum
Michael BryantMichael Bryant
Michael Bryant
Morse-type tapers at the head–stem junction in total hip replacements (THRs) provide many benefits to permit a successful surgical outcome. However, with the introduction of modular tapered devices comes complications associated with fluid ingress and motion at the interface that can cause fretting corrosion, which has been implicated in clinical failure. Increased surface roughness amplitude (Ra) and angular mismatch to ensure taper contact closer to the equator of the femoral head are design features introduced for use with ceramic heads but have been adopted by metal head couples. While increased surface roughness amplitude has been found to contribute to fretting corrosion, there is a distinct lack of systematic studies investigating the interactions between angular mismatch and Ra. This study measured the fretting corrosion and motion response of clinically representative samples, in part reference to ASTM F1875, when subjected to uniaxial incremental dynamic loading. The fretting corrosion response was measured in situ with an integrated three electrode electrochemical cell. Motion at the head–neck interface was measured with a bespoke motion measurement solution based on eddy-current principles which uses four sensors to allow motion to be fully characterised in three dimensions. Key findings from this study included a 5–10-fold increase in current measured in the increased roughness amplitude samples, suggesting an increased susceptibility to fretting corrosion without a corresponding increase in motion. The distal samples engaged around the opening of the taper interface and presented the lowest current measurements but most off-axis subsidence. Findings from this study indicate that optimisation of the taper interfaces in THR, in terms of fretting corrosion and motion, can be made and can be assessed using short-term preclinical tests.