Toxic industrial chemicals (TICs), when accidentally released into the workplace or environment, often form a gaseous mixture that complicates detection and mitigation measures. However, most of the existing gas sensors are unsuitable for detecting such mixtures. In this study, we demonstrated the detection and identification of gaseous mixtures of TICs using a chemiresistor array of single-walled carbon nanotubes (SWCNTs). The array consists of three SWCNT chemiresistors coated with different molecular/ionic species, achieving a limit of detection (LOD) of 2.2 ppb for ammonia (NH3), 820 ppb for sulfur dioxide (SO2), and 2.4 ppm for ethylene oxide (EtO). By fitting the concentration-dependent sensor responses to an adsorption isotherm, we extracted parameters that characterize each analyte-coating combination, including the proportionality and equilibrium constants for adsorption. Principal component analysis confirmed that the sensor array detected and identified mixtures of two TIC gases: NH3/SO2, NH3/EtO, and SO2/EtO. Exposing the sensor array to three TIC mixtures with various EtO/SO2 ratios at a fixed NH3 concentration showed an excellent correlation between the sensor response and the mixture composition. Additionally, we proposed concentration ranges within which the sensor array can effectively detect the gaseous mixtures. Being highly sensitive and capable of analyzing both individual and mixed TICs, our gas sensor array has great potential for monitoring the safety and environmental effects of industrial chemical processes.
1 June 2023 in ECS Journal of Solid State Science and Technology
Early detection of chemical warfare agents (CWAs) is critical in minimizing the exposure to chemical threats. This study presents a fast response-recovery chemicapacitive sensor (chemicapacitor) for a nerve agent simulant, dimethyl methylphosphonate (DMMP), with high selectivity and sensitivity. Chemicapacitors with interdigitated electrodes were fabricated on a SiO2/Si wafer by aligning single-walled carbon nanotubes (SW-CNTs) coated with polyhedral oligomeric silsesquioxane-supported 1,1,1,3,3,3-hexafluoro-2-propanol (POSS-HFIP) receptors. The stable, nano-sized three-dimensional structure with multiple terminal alcohol groups played a crucial role as a high-performance receptor via efficient hydrogen-bonding interaction with the CWA simulant. The response and recovery times of the fabricated chemicapacitors were estimated to be 13 and 88 s, respectively, outperforming chemiresistive sensors in terms of response-recovery dynamics. The capacitive responses were obtained at varying DMMP vapor concentrations, ranging from 25 to 150 ppm, and they exhibited superior sensitivity compared to receptor-free sensor devices. The concentration-dependent sensitivity was well-fitted with the Langmuir isotherm model, indicating that the sensing mechanism is based on the adsorption/desorption process. In addition, excellent selectivity was realized by introducing different toxic molecules (sulfur dioxide, ammonia, and ethylene oxide) and a blood agent (cyanogen chloride), where the fabricated POSS-HFIP/SW-CNTs chemicapacitor selectively responded to the DMMP vapor. The limit-of-detection was calculated to be 0.70 ppm. The proposed POSS-HFIP/SW-CNTs chemicapacitor demonstrated rapid response-recovery characteristics (with improved selectivity towards DMMP), suggesting its potential in reducing casualties or injuries by early identification of CWAs.