We sought to determine the role of the patient-specific, three-dimensional (3D) holographic vascular model in patient medical knowledge and its influence on obtaining a more conscious informed consent process for percutaneous balloon angioplasty (PTA). Patients with peripheral arterial disease who had been scheduled for PTA were enrolled in the study. Information regarding the primary disease, planned procedure, and informed consent was recorded in typical fashion. Subsequently, the disease and procedure details were presented to the patient, showing the patients their individual model. A patient and medical supervisor equipped with mixed reality headsets could both simultaneously manipulate the hologram using gestures. The holographic 3D model had been created on a scale of 1:1 based on computed tomography scans. The patient’s knowledge was tested by the completion of a questionnaire before and after the interaction in a mixed reality environment. Seventy-nine patients manipulated arterial holograms in mixed reality head-mounted devices. Before the 3D holographic artery model interaction, the mean ± standard deviation score of the knowledge test was 2.95 ± 1.21 points. After the presentation, the score had increased to 4.39 ± 0.82, with a statistically significant difference (p = 0.0000) between the two scores. Using a Likert scale from 1 to 5, the patients had scored the use of the 3D holographic model at 3.90 points regarding its usefulness in comprehending their medical condition; at 4.04 points regarding the evaluation of the holograms as helpful in understanding the course of surgery; and rated the model at 1.99 points in reducing procedure-related stress. Using a nominal scale (know or don’t know), the patients had self-assessed their knowledge of the procedure before and after the 3D model presentation, with a score of 6.29 ± 2.01 and 8.39 ± 1.54, respectively. The study group tolerated the use of head-mounted devices. Only one patient had nausea and dizziness, while four patients experienced transient eye pain. The 3D holographic arterial model aided in the understanding of patients’ knowledge regarding the disease and procedure, making the informed consent process more conscious. The holograms improved the patient’s self-consciousness. Mixed reality headset-related complications were rare and within acceptable rates.
This study aimed to investigate the relationship between maximum transverse diameter (MTD) and volume measurements in patients who underwent reoperations after endovascular aneurysm repair (EVAR), and their association with the occurrence of endoleaks. The study included 51 patients who underwent EVAR and subsequent re-operations caused by endoleaks type I–III. In some number of events, multiple re-operations were needed. MTD was measured using the Horos software, and segmentations of the AAA were performed using 3D Slicer. This study first evaluated post-operative computed tomography angiography (CTA) to measure MTD and volume. Then, similar measurements were made in the control scan for re-operation qualification. Negative remodeling (increase in MTD and/or volume) was observed in 40 cases using MTD, and 48 cases using volume measurements. The volume measurement showed lower missed negatives than MTD, indicating its effectiveness in screening for negative remodeling (p < 0.001). Combining both methods identified 51 negative remodeling cases and 8 positive changes, with a higher sensitivity compared to MTD alone. The volume of the sac did not predict specific endoleak types. Decreases in MTD were observed in smaller sacs, with smaller volume changes. Volume measurement is a valuable screening tool, and combining MTD and volume enhances sensitivity. However, sac volume does not predict endoleak type.
Background: This study addresses the need for enhanced patient education in the context of abdominal aortic aneurysm (AAA) and its treatment through endovascular aneurysm repair (EVAR). Effective patient education is essential for improving comprehension and engagement, particularly for those facing complex medical conditions. Methods: A total of 55 patients scheduled for EVAR participated in the study. Patient-specific three-dimensional (3D)-printed models of the participants’ aneurysms were created using computed tomography angiogram (CTA) scans. The educational intervention included a structured session utilizing these 3D models, with assessments conducted before and after the session, including the Mini-Mental State Examination (MMSE). Statistical analyses evaluated the knowledge gain and its correlation with cognitive function. Results: The results showed a significant increase in knowledge scores post-education (p < 0.001), with a mean knowledge gain of 2.36 points. Patients rated the effectiveness of the 3D models highly on a Likert scale, with a mean score of 4.64 for improving their understanding of the medical condition and procedural aspects. A weak correlation was observed between MMSE scores and knowledge test results. Conclusions: This study demonstrates the potential of patient-specific 3D models to enhance patient education in the context of EVAR, improving patients’ understanding of their medical condition and the procedure and thereby facilitating more informed decision-making.
The purpose of this study is to find out the psychological factor characteristic of non-adherence patients. The study population comprised kidney transplant recipients aged between 18 and 82 years at least 3 months post-transplant who voluntarily agreed to answer a couple of fully anonymous questionnaires that questions pertaining to basic data, type of immunosuppressive drugs taken, and standardized questionnaires. Participants were recruited using direct routine, free-of-charge visits to specialist doctors in transplant clinics. There was no significant difference in the percentage of men and women in both adherence and non-adherence groups. Non-adherence patients were significantly younger compared to adherence patients. There was also a significant difference in the patient’s level of education. Adherence patients were better educated. No significant differences in criteria such as place of residence, having children or a partner, or way of living were observed. However, the emotion scale correlated negatively with the level of life orientation in both groups, but the level of the emotions scale and distractions subscale was negatively correlated with the level of self-esteem only for the adherence group. In future research, it would be worthwhile to focus on lifestyle and health-promoting behaviors in juxtaposition with the propensity for adherence.
18 December 2025 in Journal of Endovascular Therapy
Purpose: Endovascular treatment of aortic arch pathologies remains a significant challenge due to the anatomical complexity of the supra-aortic vessels. Traditional approaches, such as custom-made devices (CMDs) or hybrid procedures, are often limited by delayed availability, invasiveness, and long production or preparation times. Physician-modified stent-grafts (PMSGs) offer a viable alternative for high-risk emergency patients requiring urgent intervention. Methods: This single-center study evaluated the safety and efficacy of a novel PMSG technique in 18 patients with acute aortic syndromes, including ruptured or impending rupture of aneurysms and complicated dissections. Patients were selected according to defined inclusion criteria, excluding those eligible for alternative surgical or endovascular procedures. Stent-graft modifications—including single-fenestrated and triple-fenestrated grafts—were performed on the Medtronic Valiant platform using patient-specific, sterile 3-dimensional-printed templates. Technical success, early outcomes, and medium-term follow-up data were assessed, with particular attention to neurological complications, endoleaks (EL), and survival, using serial computed tomography angiography. Results: Early outcomes demonstrated 100% technical success (18 of 18 patients), with no deaths during the first 30-day postoperative period. Four patients experienced non-disabling strokes. One patient required surgical revision for access-site bleeding, and another developed transient spinal cord ischemia. Mid-term follow-up (median = 43 months) revealed an overall survival rate of 83%, with 3 deaths unrelated to the endovascular procedure. Endoleaks were detected in 5 patients. No cases of graft infection or migration were reported. Conclusion: Physician-modified stent-grafts represent a feasible and effective treatment option for high-risk patients with aortic arch pathologies requiring urgent intervention. The technique enables tailored management in cases where off-the-shelf solutions or custom devices are unavailable, offering high technical success and promising mid-term durability. Further multicenter studies are warranted to confirm long-term safety and refine procedural techniques. Clinical Impact: This study shows that physician-modified stent grafts (PMSGs) are a feasible option for high-risk patients who cannot undergo open surgery or access custom-made devices. Using 3D-printed templates improves fenestration accuracy and arterial alignment. The 100% technical success rate and absence of early mortality indicate strong short-term effectiveness. However, the off-label nature of the technique and lack of standardization require experienced teams and careful patient selection. If confirmed in larger cohorts, PMSGs could become part of emergency aortic treatment protocols and influence future device development.