Geonho Kim

Mr. Geonho Kim

Distribution Laboratory, Korea Electric Power Research Institute, Daejeon, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SHSeokWoo Hyun
SeokWoo Hyun
GKGeonho Kim
Geonho Kim
JPJungsung Park
Jungsung Park
YCYun-Hyuk Choi
Yun-Hyuk Choi
This study addresses the challenges of grid stability posed by the integration of renewable energy sources, focusing on regions, like Jeju Island, where overgeneration complicates energy management. We introduce a novel sensitivity-based control algorithm for Virtual Power Plants (VPPs) that optimizes the deployment of distributed energy resources (DERs). Unlike conventional curtailment methods, such as Last In, First Out (LIFO) and Pro-rata, which often overlook the nuanced impacts of individual DERs on grid stability, our approach leverages electrical sensitivity analysis. This analysis quantifies the effect of each DER on voltage stability, allowing resources to be grouped and managed based on their specific sensitivity. By deriving the sensitivity matrix from the Jacobian matrix of power flow equations, the algorithm identifies critical DERs that significantly influence grid conditions, enabling more strategic curtailment decisions. The proposed method was validated using real-world data from Jeju Island, demonstrating improved efficiency and reduced curtailment compared to existing techniques. These findings underscore the potential of sensitivity-based control to enhance the efficiency of renewable energy systems, supporting sustainable energy transitions.

14 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
GKGeonho Kim
Geonho Kim
TKTae-Hwan Kim
Tae-Hwan Kim
JKJun-Hyeok Kim
Jun-Hyeok Kim
This study analyzes recloser operation in the South Korean distribution system to propose effective operational strategies for improving safety and efficiency. This research is based on actual data, such as recloser operation data and fault statistics provided by the Ministry of the Interior and Safety and the Korea Electric Power Corporation, without the use of simulation tools or experiments. Key operational elements, such as reclosure counts, sequence settings, and high-current interruption features, were analyzed. First, an analysis of reclosure counts revealed that over 73% of faults were cleared after the first reclosure, and when the second reclosure was included, more than 90% were successfully restored. This finding suggests that reducing the number of reclosures from the standard three to one or two would not significantly impact fault restoration performance while simultaneously reducing arc generation, thereby improving safety. Additionally, a review of recloser sequence settings highlighted the fact that the traditional 2F2D (two fast, two delayed) sequence often led to frequent instantaneous tripping, increasing the risk of arc generation. The 1F1D (one fast, one delayed) sequence, which applies a delayed trip after an initial fast trip, offers a better fault-clearing performance and reduces the risk of arc generation. Lastly, an analysis of the high-current interruption feature suggested that enabling this function for faults with low reclosing success rates, particularly in cases of short-circuit faults, and setting an immediate trip threshold for fault currents exceeding 3 kA would enhance both safety and efficiency. This operational strategy was implemented in the South Korean distribution system over a three-year period, starting in 2021. While there was a 2.1% decrease in reclosure success rates, this strategy demonstrated that similar success levels could be maintained while reducing the number of reclosures, thus mitigating equipment damage risks and improving safety measures. The refined recloser operation plan derived from this study is expected to enhance the overall stability and reliability of distribution systems.

16 June 2023 in Electronics
Verified
Journal Article
Open access
PDF file
GKGeonho Kim
Geonho Kim
WKWoo-Hyun Kim
Woo-Hyun Kim
LCLee Chun-kwon
Lee Chun-kwon
Distribution systems are mostly composed of radial structures, which are susceptible to an increased variability and complexity of system operation due to frequent line changes during operation. When multiple changes in distribution lines occur simultaneously, the relative positions of protective devices also change. The existing protection coordination method of distribution lines is configured by considering the operation characteristics and coordination time interval (CTI) of all protective devices in series from the substation to the terminal load. Therefore, the protection coordination algorithm needs to be redesigned whenever a line is changed or a protective device is added to the distribution line for which the existing protection coordination algorithm has been set. In addition, existing protection coordination methods require complex calculations and procedures, which are subject to human errors and are less feasible for responding in real-time to changes in the distribution system. In this paper, we propose the adaptive time–current curve (TCC) method by selecting the time dial setting (TDS) and minimum response time (MRT) of individual protective devices in accordance with the relative distance based on the linear optimization technique. Using PSCAD/EMTDC, a power system analysis program, the minimum operating current and the fault current of each protective device are obtained, and the proposed protection coordination algorithm is verified according to the series configuration relationship of the protective devices. Finally, the proposed method is applied to an actual distribution line to verify the improvement over the existing protection coordination.

23 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
GKGeonho Kim
Geonho Kim
JKJun-Hyeok Kim
Jun-Hyeok Kim
Power system planning requires reliable information about feeder-level photovoltaic (PV) variability, but point forecasts are often uncertain. This study proposes a procedure for constructing explainable, frequency-aware representative bands for daily PV output at the feeder section level. The method segments the annual PV series into homogeneous periods, derives reference shapes from probabilistically clustered daily profiles, and selects an upper band that balances coverage, shape fidelity, and upper tail risk through multi-objective optimization. Validation on real feeder data shows that the bands enclose frequent and recent shapes (average weighted coverage ≈ 0.85), limit upward exceedances (≈0.06), and remain compact. The approach supports practical threshold and reserve planning and provides a transparent complement to point forecasts by emphasizing typical operating regimes while remaining cautious about extremes.