Yun-Hyuk Choi

Prof. Yun-Hyuk Choi

Daegu Catholic University, Daegu, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SHSeokWoo Hyun
SeokWoo Hyun
GKGeonho Kim
Geonho Kim
JPJungsung Park
Jungsung Park
YCYun-Hyuk Choi
Yun-Hyuk Choi
This study addresses the challenges of grid stability posed by the integration of renewable energy sources, focusing on regions, like Jeju Island, where overgeneration complicates energy management. We introduce a novel sensitivity-based control algorithm for Virtual Power Plants (VPPs) that optimizes the deployment of distributed energy resources (DERs). Unlike conventional curtailment methods, such as Last In, First Out (LIFO) and Pro-rata, which often overlook the nuanced impacts of individual DERs on grid stability, our approach leverages electrical sensitivity analysis. This analysis quantifies the effect of each DER on voltage stability, allowing resources to be grouped and managed based on their specific sensitivity. By deriving the sensitivity matrix from the Jacobian matrix of power flow equations, the algorithm identifies critical DERs that significantly influence grid conditions, enabling more strategic curtailment decisions. The proposed method was validated using real-world data from Jeju Island, demonstrating improved efficiency and reduced curtailment compared to existing techniques. These findings underscore the potential of sensitivity-based control to enhance the efficiency of renewable energy systems, supporting sustainable energy transitions.

19 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
YCYunsung Cho
Yunsung Cho
YCYun-Hyuk Choi
Yun-Hyuk Choi
This paper describes a methodology for implementing the state estimation and enhancing the accuracy in large-scale power systems that partially depend on variable renewable energy resources. To determine the actual states of electricity grids, including those of wind and solar power systems, the proposed state estimation method adopts a fast-decoupled weighted least square approach based on the architecture of application common database. Renewable energy modeling is considered on the basis of the point of data acquisition, the type of renewable energy, and the voltage level of the bus-connected renewable energy. Moreover, the proposed algorithm performs accurate bad data processing using inner and outer functions. The inner function is applied to the largest normalized residue method to process the bad data detection, identification and adjustment. While the outer function is analyzed whether the identified bad measurements exceed the condition of Kirchhoff’s current law. In addition, to decrease the topology and measurement errors associated with transformers, a connectivity model is proposed for transformers that use switching devices, and a transformer error processing technique is proposed using a simple heuristic method. To verify the performance of the proposed methodology, we performed comprehensive tests based on a modified IEEE 18-bus test system and a large-scale power system that utilizes renewable energy.

9 November 2022 in Electronics
Verified
Journal Article
Open access
PDF file
DongYeong GwonDongYeong Gwon
DongYeong Gwon
YCYun-Hyuk Choi
Yun-Hyuk Choi
JSJUNBO SIM
JUNBO SIM
Problems with overvoltage and reverse energy flow arise as the percentage of distribution energy resources (DERs) in distribution system rises. This paper implements a MATLAB/Simulink linked model that communicates with the OpenDSS engine. The point of common coupling (PCC) voltage typically mitigates using the inverter outputs control. However, case overvoltage issues occur in distribution networks and the influence of the volt–var control effect is insufficient to reduce PCC voltage to a stable range. To improve the reactive control effect, this paper proposes active power control and voltage error compensation methods that maximize the reactive power control effect. The DER management system (DERMS) platform was constructed to analyze the effect of changing DER output values. The DERMS data are organized based on real distribution line (D/L) system data where overvoltage occurred in Korea and the control effect of the real system is analyzed. This control method analysis can be used to develop an inverter control scheme for the over voltage issues described in this paper.

16 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
YCYun-Hyuk Choi
Yun-Hyuk Choi
YCYunsung Cho
Yunsung Cho
This paper proposes an advanced continuous voltage control method that implements multiple-point control to ensure peak power system performance. Most control schemes utilize generators to regulate the pilot point voltage of a control area. However, exact control of a single pilot point is difficult because of the influence of adjacent areas in a meshed power system. To address this challenge, the proposed method accesses multiple pilot points to mitigate the effects of the neighboring area. In simulations of the Korean power system, the proposed control scheme offered a considerable improvement in performance when compared with the conventional, currently implemented voltage control system.

26 January 2026 in Electronics
Verified
Journal Article
Open access
PDF file
DongYeong GwonDongYeong Gwon
DongYeong Gwon
YCYun-Hyuk Choi
Yun-Hyuk Choi
This study investigated the fault ride through capability of inverter-based resources in weak distribution networks and proposes a fault-oriented reactive power compensation strategy using only point of common coupling voltage measurements. The proposed strategy determines the reactive power command based on the minimum phase voltage, which represents the most severely depressed phase during unbalanced faults, without fault type detection or sequence component analysis. As a result, the same control framework can be applied to single-line-to-ground, double-line-to-ground, and three-phase faults. A detailed MATLAB/Simulink model of a Korean distribution feeder was developed using actual system parameters. The proposed strategy was compared with a no control case and a conservative fixed capacity reactive power injection scheme derived from commonly adopted power factor limits. Simulation results show that the no control case provides no voltage support, while the fixed capacity approach yields limited improvement in weak grids. In contrast, the proposed strategy maintains stable inverter operation and improves voltage recovery. At locations with an extremely low weighted short circuit ratio of 0.303, the proposed strategy prevents inverter tripping during temporary faults and satisfies low voltage ride through requirements, demonstrating its practical effectiveness.

1 October 2009
Verified
Conference Paper
Closed access
YCYun-Hyuk Choi
Yun-Hyuk Choi
SSSangSoo Seo
SangSoo Seo
BLByongjun Lee
Byongjun Lee
SNSu-Chul Nam
Su-Chul Nam
JSJeongHoon Shin
JeongHoon Shin
TKTae-Kyun Kim
Tae-Kyun Kim
This paper proposes a voltage and reactive power control methodology, which is motivated towards implementation in the KEPCO power system. The main voltage control devices are generators in continuous type and make sure capacitors and reactors in discrete type. Effects of control devices are evaluated by pure reactive power reserve that is exactly to guarantee generator's reactive power margin for severe conditions. The control targets are each of critical buses of local subsystems that are decided by electrical distance in the whole system. The control objectives are to keep the voltage profile and to guarantee the reactive power reserve within constraints with the limit of generator output. A robust control strategy is proposed to make the control feasible and optimal for severe contingency cases indicate that the proposed control methodology is much more effective than conventional voltage control scheme in the KEPCO system.