User experience and user acceptance of a product are essential for the product’s success. Virtual reality (VR) technology has the potential to assess these parameters early in the development process. However, research is scarce on whether the evaluation of the user experience and user acceptance of prototypes in VR, as well as the simulation of the usage environment, lead to comparable results to reality. To investigate this, a digital twin of a blood pressure monitor (BPM) was created using VR. In a 2 × 2 factorial between-subjects design, 48 participants tested the real or VR BPM. The tests were performed either in a low-detail room at a desk or in a detailed operating room (OR) environment. Participants executed three use scenarios with the BPM and rated their user experience and acceptance with standardized questionnaires. A test leader evaluated the performance of the participants’ actions using a three-point scheme. The number of user interactions, task time, and perceived workload were assessed. The participants rated the user experience of the BPM significantly (p< .05) better in VR. User acceptance was significantly higher when the device was tested in VR and in a detailed OR environment. Participant performance and time on task did not significantly differ between VR and reality. However, there was significantly less interaction with the VR device (p< .001). Participants who tested the device in a detailed OR environment rated their performance significantly worse. In reality, the participants were able to haptically experience the device and thus better assess its quality. Overall, this study shows that user evaluations in VR should focus on objective criteria, such as user errors. Subjective criteria, such as user experience, are significantly biased by VR.
Virtual reality (VR) enables prototypes of devices to be evaluated in a simulation of a future usage environment. A disadvantage is the insufficient feedback design during the interaction with prototypes. In this study, we investigated how virtual control elements in VR must be designed to compensate for the lack of feedback. Therefore, 35 participants performed VR tasks using a virtual joystick and virtual rotary control. According to the design of experiments method, 12 factors, such as haptic feedback, sensitivity, size, and shape, were systematically varied. The control accuracy, task time, user experience, presence, and mental workload were recorded. The effect of a factor on the recorded parameters was examined using multifactorial ANOVA. Linear regression was used to calculate the mathematical models between the factors and parameters. These models were used to calculate the optimal design of the control elements in the VR. For rotary control, eight factors had a significant influence on the recorded parameters. There were seven factors for the joystick. With mathematical models, optimized control element designs for VR were calculated for the first time. These findings can help to better adapt prototypes and human–machine interfaces to different modalities in VR.
User evaluations of prototypes in virtual reality (VR) offer high potential for products that require resource-intensive prototype construction, such as drilling rigs. This study examined whether the user evaluation of a VR prototype for controlling an onshore drilling rigproduces results comparable to an evaluation in the real world. Using a between-subject design, 16 drilling experts tested a prototype in VR and reality. The experts performed three different work processes and evaluated their satisfaction based on task performance, user experience, and usability via standardized questionnaires. A test leader evaluated the effectiveness of the work process execution using a 3-level rating scheme. The number of user interactions and time on task were recorded. There were no significant differences in the effectiveness, number of interactions required, perceived usability, and satisfaction with respect to task performance. In VR, the drilling experts took significantly more time to complete tasks and rated the efficiency of the VR prototype significantly higher. Overall, the real-world evaluation provided more insights into prototype optimization. Nevertheless, several usability issues have been identified in VR. Therefore, user evaluations in VR are particularly suitable in the early development phases to identify usability issues, without the need to produce real prototypes.
Background: Musculoskeletal disorders (MSDs) are highly prevalent among healthcare workers, particularly nurses, with reported prevalence rates ranging from 57% to 93%. Perfusionists are highly specialized healthcare professionals responsible for operating heart–lung machines during cardiac surgery. To date, the prevalence of MSDs in this professional group has not been systematically investigated. To address this gap, perfusionists in Germany were surveyed regarding MSDs. Methods: The German version of the Nordic Musculoskeletal Questionnaire (NMQ) was administered. Pearson’s correlation and chi-square tests were applied. Results: A total of 287 perfusionists (72 female, 215 male; age 42.6 ± 11.9 years, professional experience 13.5 ± 10.9 years) from 45 German cardiac centers participated. Overall, 86% reported MSDs, with the lower back (65.5%) and neck (58.9%) being the most frequently affected regions, and 4.5% to 36.6% in other body regions. Increasing age was significantly associated with a higher prevalence in six body regions, and greater professional experience was associated in five regions. Occupational risk factors previously identified in nursing are assumed to apply to perfusion practice. Conclusions: This study demonstrates a high prevalence of MSDs among perfusionists in Germany. These findings underscore the need for preventive measures, coping strategies, and further research to reduce work-related musculoskeletal strain among perfusionists.
This study investigated a novel motorized drive wheel designed to replace one of the four outer castors of a hospital bed. Existing beds can be retrofitted using a plug-and-play approach, offering considerable potential to reduce the physical burden on healthcare workers during bed transport. Thirteen nurses moved a standardized hospital bed-with and without the drive wheel-through a realistic course including ramps, curves, and elevators. Objective biomechanical parameters (hand forces, spinal compression, muscle activity) and subjective assessments (Borg scale, System Usability Scale) were recorded. The drive wheel significantly reduced physical load, lowering hand forces by 22 % and spinal compression by 20 %. Shoulder, neck, and lower-back muscle activity also decreased significantly. Perceived exertion was reduced by 69 %, and usability was rated as "excellent." The motorized drive wheel evaluated in this study substantially reduced physical load in everyday clinical care, although recommended ergonomic limits were not met in all situations.
Extravasation is a phenomenon that occurs when the infusion solution misses the vein and enters the surrounding tissue. We developed a sensor prototype utilising impulse oscillometry to detect extravasations at an early stage. A hydraulic impulse is injected into the infusion line to observe and analyse its progress. The aim of this study was to determine the tissue parameters that might influence the sensor measurement signal and signal changes during extravasation. We developed a simulator that simulates infusions and extravasations to test the prototype. Tissue-specific parameters can be adjusted independently. The effects of the tissue parameters, including blood pressure, blood flow, blood density, blood viscosity, vein diameter, venous wall thickness, and tissue modulus of elasticity, were investigated using the design of experiments method. The parameter values were varied between two levels and tested across 16 experiments. Blood pressure, blood viscosity, vein diameter, and venous compliance demonstrated the greatest impact on the sensor signal (p < .001). The other parameters showed negligible effects. Significant differences (p = .006) in the pressure signal of the sensor could be observed when the catheter changed from the venous position to the extravasal position.