See-through augmented reality glasses, such as HoloLens 2, are increasingly adopted in medical settings; however, their efficacy as medical display devices remains unclear, as current evaluation protocols are designed for traditional monitors. This study examined whether the established display-evaluation techniques apply to HoloLens 2 and whether it meets standards for primary and secondary medical displays. HoloLens 2 was assessed for overall image quality, luminance, grayscale consistency, and color uniformity. Five participants rated the TG18-OIQ pattern under ambient lighting conditions of 2.4 and 138.7 lx. Minimum and maximum luminance were measured using the TG18-LN12-03 and -18 patterns, targeting ≥ 300 cd/m2 and a luminance ratio ≥ 250. Grayscale conformity to the standard grayscale display function allowed deviations of 10% for primary and 20% for secondary displays. Color uniformity was measured at five screen positions for red, green, and blue, with a chromaticity limit of 0.01 for primary displays. HoloLens 2 satisfied four of the ten primary and four of the seven secondary overall-quality criteria, achieving a maximum luminance of 2366 cd/m2 and a luminance ratio of 1478.75. Grayscale uniformity was within tolerance for 10 of the 15 primary and 13 of the 15 secondary measurements, while 25 of the 30 color uniformity values exceeded the threshold. The adapted evaluation methods facilitate a systematic assessment of HoloLens 2 as a medical display. Owing to inadequate grayscale and color representation, the headset is unsuitable as a primary diagnostic display; for secondary use, requirements must be assessed based on specific application requirements.
User evaluations of prototypes in virtual reality (VR) offer high potential for products that require resource-intensive prototype construction, such as drilling rigs. This study examined whether the user evaluation of a VR prototype for controlling an onshore drilling rigproduces results comparable to an evaluation in the real world. Using a between-subject design, 16 drilling experts tested a prototype in VR and reality. The experts performed three different work processes and evaluated their satisfaction based on task performance, user experience, and usability via standardized questionnaires. A test leader evaluated the effectiveness of the work process execution using a 3-level rating scheme. The number of user interactions and time on task were recorded. There were no significant differences in the effectiveness, number of interactions required, perceived usability, and satisfaction with respect to task performance. In VR, the drilling experts took significantly more time to complete tasks and rated the efficiency of the VR prototype significantly higher. Overall, the real-world evaluation provided more insights into prototype optimization. Nevertheless, several usability issues have been identified in VR. Therefore, user evaluations in VR are particularly suitable in the early development phases to identify usability issues, without the need to produce real prototypes.
27 September 2021 in ASU Arbeitsmedizin Sozialmedizin Umweltmedizin
In diesem Beitrag wird mittels vergleichender Nutzendentests mit einem realen und einem virtuellen Prototyp eines Blutdruckmessgerätes die Eignung von VR-Prototypen zur Usability-Evaluation von Medizinprodukten untersucht. Dafür werden mit insgesamt 24 Testpersonen Nutzendentests durchgeführt.
Extracorporeal membrane oxygenation (ECMO) procedures may result in emergencies requiring the intervention of a perfusionist. However, their arrival results in waiting times that put patients at risk. Hence, nursing staff should be remotely supported using augmented reality (AR) in troubleshooting to improve patient safety. In this study, we aimed to investigate the usability of AR glasses HMT-1 and HoloLens 2 for remote support during ECMO and to determine the user acceptance of AR in intensive care. Ten nurses tested both glasses in a user test in randomized order under perfusionist guidance to rectify the three ECMO emergencies: a signal alert, a pump failure and reduced blood flow. An investigator rated their skills using a 3-step scheme, and success rates were calculated from the ratings and compared using the Wilcoxon test (α =.05). AR acceptance was assessed using the System Usability Scale (SUS) and User Experience Questionnaire (UEQ). We recorded 12 and 21 use errors with HMT-1 and HoloLens 2, respectively. However, significantly fewer use errors occurred with the HMT-1 than with HoloLens 2 (Z = -1786, p = .046, n = 80) when troubleshooting the pump failure. Most participants rated HoloLens 2 as more suitable. AR acceptance was rated as good with a SUS score of 72 (± 11). UEQ ratings for attractiveness, dependability, stimulation, novelty, and efficiency were excellent or good, while perspicuity was rated below average. The results indicate that both AR glasses are suitable for remote support; however, improvements to increase efficiency and patient safety in intensive care are necessary.