Runcheng Fang

Ms. Runcheng Fang

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2023 in Toxics
Verified
Journal Article
Open access
PDF file
RFRuncheng Fang
Runcheng Fang
AMAfzaal Nadeem Mohammed
Afzaal Nadeem Mohammed
JYJagjit S Yadav
Jagjit S Yadav
JWJun Wang
Jun Wang
Previous research has indicated that ultrafine particles (UFPs, particles less than 100 nm) emitted from desktop three-dimensional (3D) printers exhibit cytotoxicity. However, only a limited number of particles from different filaments and their combinations have been tested for cytotoxicity. This study quantified the emissions of UFPs from a commercially available filament extrusion desktop 3D printer using three different filaments, including acrylonitrile butadiene Styrene (ABS), thermoplastic polyurethane (TPU), and polyethylene terephthalate glycol (PETG). In this study, controlled experiments were conducted where the particles emitted were used to expose cells grown in an air-liquid interface (ALI) system. The ALI exposures were utilized for in vitro characterization of particle mixtures, including UFPs from a 3D printer. Additionally, a lactate dehydrogenase (LDH) assay was used to evaluate the cytotoxic effects of these UFPs. A549 cells were exposed at the ALI to UFPs generated by an operational 3D printer for an average of 45 and 90 min. Twenty-four hours post-exposure, the cells were analyzed for percent cytotoxicity in a 24-well ALI insert (LDH assay). UFP exposure resulted in diminished cell viability, as evidenced by significantly increased LDH levels. The findings demonstrate that ABS has the most significant particle emission. ABS was the only filament that showed a significant difference compared to the high efficiency particulate arrestance (HEPA) following 90 min of exposure (p-value < 0.05). Both ABS and PETG exhibited a significant difference compared to the HEPA control after 45 min of exposure. A preliminary analysis of potential exposure to these products in a typical environment advises caution when operating multiple printer and filament combinations in poorly ventilated spaces or without combined gas and particle filtration systems.

29 December 2023 in Annals of Work Exposures and Health
Verified
Journal Article
Closed access
PDF file
RFRuncheng Fang
Runcheng Fang
NANiles Andrus
Niles Andrus
TDThomas Dominguez
Thomas Dominguez
DSDarrah Sleeth
Darrah Sleeth
RJRachael M. Jones
Rachael M. Jones
Healthcare personnels (HCPs) are at risk of respiratory infectious diseases during patient care activities. HCPs rely primarily on personal protective equipment to prevent pathogen exposures, but there is a need to develop alternative, or complementary control strategies, including engineering controls. The objective of this study was to evaluate the ability of the 3 designs (denoted D1A, D1B, and D2) of the University of Utah Containment Ventilation for Exposure Reduction (U-COVER), a protective barrier enclosure device to contain respirable aerosols when placed over a simulated patient. The 2 primary performance metrics were the percent reduction in: (i) the concentration of respirable aerosols in the simulated breathing zone of an HCP, and (ii) surface contamination outside the device, which were tested using salt aerosols and fluorescein aerosols, respectively. Briefly, salt or fluorescein aerosols were generated as though expelled by a prone patient under 3 conditions: (i) no device (control), (ii) with the device but without exhaust ventilation, and (iii) with the device with exhaust ventilation. Device D2 was also tested under simulated use conditions, in which cardboard “arms” were placed inside the device ports. All 3 device designs showed the ability to reduce particle concentrations in the simulated HCP breathing zone and on surfaces by >99% with exhaust ventilation compared to the control condition. Without exhaust ventilation, device performance was lower and highly variable. Under simulated use conditions, device D2 reduced particle concentrations in the simulated HCP breathing zone by ≥91% and on surfaces by >99% relative to control for all combinations of “arms” tested. The U-COVER device demonstrates excellent aerosol containment and warrants further testing with dynamic simulated or actual use conditions.

19 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
RFRuncheng Fang
Runcheng Fang
JWJun Wang
Jun Wang
AMAfzaal Nadeem Mohammed
Afzaal Nadeem Mohammed
JYJagjit S Yadav
Jagjit S Yadav
Previous research via cell experiments has shown that ultrafine particles (UFPs, particles less than 100 nm) emitted from Three-Dimensional desktop printers (3D printers) had cytotoxicity. However, a few particles from different filaments and their cytotoxicity combinations have been tested. Here we quantify emissions of UFPs and use Air-Liquid Interface (ALI) from one commercially available filament extrusion desktop 3D printer utilizing three different filaments by controlled experiments. A549 cells were exposed at the ALI to UFPs generated by a working 3D printer for an average of 45 minutes and 90 minutes. Twenty-four hours after exposure, cells were analyzed for percent cytotoxicity grown on the 24-well ALI insert (LDH assay). UFP exposure resulted in decreased cell viability (significantly increased LDH levels). The result shows that Acrylonitrile butadiene styrene (ABS) has the most significant particle emission. ALI exposures enable in vitro testing of mixtures of particles such as UFP from a 3D printer. ABS is the only filament with a significant difference compared with the HEPA control in 90 minutes of exposure (p-value <0.05). ABS and PETG we used during the experiment presented a significant difference compared with the HEPA control in 45 minutes of exposure.A screening analysis of potential exposure to these products in a typical environment suggests caution should be used when operating many printer and filament combinations in poorly ventilated spaces or without the aid of combined gas and particle filtration systems.

12 March 2026 in Annals of Work Exposures and Health
Verified
Journal Article
Closed access
RFRuncheng Fang
Runcheng Fang
SCScott Collingwood
Scott Collingwood
KKKerry Kelly
Kerry Kelly
DSDarrah Sleeth
Darrah Sleeth
Low-cost PM2.5 sensors are increasingly used for ambient and indoor air quality monitoring, but their performance in high-concentration occupational environments remains uncertain. This study compares linear regression (LR), polynomial regression (PR), and random forest (RF) calibration models for low-cost PM2.5 sensors operating in a controlled high-concentration chamber. This study assessed the calibration performance of low-cost aerosol sensors (LCS) by employing LR, PR, and RF models across various aerosol (PM2.5) concentration ranges. Conventional LR models demonstrated solid performance when dealing with lower concentrations (0 to 150 µg/m3), but their accuracy diminished when confronted with higher concentrations. On the other hand, RF models continuously demonstrated better performance over all concentration ranges, making them potentially more appropriate for occupational situations with higher and fluctuating aerosol levels. PR models exhibited intermediate performance, surpassing that of LR but falling short of the robustness demonstrated by RF. The study highlights the importance of using modern calibration methods such as RF in locations with high concentrations to enable accurate aerosol monitoring using LCS. These results could lead to the development of efficient and cost-effective methods for monitoring air quality using LCS for high concentration environments.

14 September 2026 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
RBRyan Bellacov
Ryan Bellacov
TGThomas Gerding
Thomas Gerding
RFRuncheng Fang
Runcheng Fang
JWJun Wang
Jun Wang
WHWei-Wen Hsu
Wei-Wen Hsu
Firefighters are exposed to multiple occupational hazards, including airborne contaminants, chemical, biological, physical, and ergonomic risks (Fahy et al. 2020). In the United States, firefighter...