Air samples were collected in 12 randomly selected commercial nail salons in Salt Lake County, Utah. Measurements of salon physical/chemical parameters (room volume, CO2 levels) were obtained. Volatile organic compound (VOC) concentrations were collected using summa air canisters and sorbent media tubes for an 8-h period. Multivariate analyses were used to identify relationships between salon physical/chemical characteristics and the VOCs found in the air samples. The ACGIH® additive mixing formula was also applied to determine if there were potential overexposures to the combined airborne concentrations of chemicals monitored. Methyl methacrylate was detected in 58% of the establishments despite having been banned for use in nail products by the state of Utah. Formaldehyde was found above the NIOSH REL® (0.016 ppm) in 58% of the establishments. Given the assortment of VOCs to which nail salon workers are potentially exposed, a combination of engineering as well as personal protective equipment is recommended.
Health care workers (HCWs) can acquire infectious diseases, including coronavirus disease 2019 (COVID-19), from patients. Herein, COVID-19 is used with the source–pathway–receptor framework as an example to assess evidence for the roles of aerosol transmission and indirect contact transmission in viral respiratory infectious diseases. Evidence for both routes is strong for COVID-19 and other respiratory viruses, but aerosol transmission is likely dominant for COVID-19. Key knowledge gaps about transmission processes and control strategies include the distribution of viable virus among respiratory aerosols of different sizes, the mechanisms and efficiency by which virus deposited on the facial mucous membrane moves to infection sites inside the body, and the performance of source controls such as face coverings and aerosol containment devices. To ensure that HCWs are adequately protected from infection, guidelines and regulations must be updated to reflect the evidence that respiratory viruses are transmitted via aerosols.
The assessment of personal inhalable aerosol samplers in a controlled laboratory setting has not previously been carried out at the ultra-low wind speed conditions that represent most modern workplaces. There is currently some concern about whether the existing inhalable aerosol convention is appropriate at these low wind speeds and an alternative has been suggested. It was therefore important to assess the performance of the most common personal samplers used to collect the inhalable aerosol fraction, especially those that were designed to match the original curve. The experimental set-up involved use of a hybrid ultra-low speed wind tunnel/calm air chamber and a rotating, heating breathing mannequin to measure the inhalable fraction of aerosol exposure. The samplers that were tested included the Institute of Occupational Medicine (IOM), Button, and GSP inhalable samplers as well as the closed-face cassette sampler that has been (and still is) widely used by occupational hygienists in many countries. The results showed that, down to ∼0.2 m s−1, the samplers matched the current inhalability criterion relatively well but were significantly greater than this at the lowest wind speed tested. Overall, there was a significant effect of wind speed on sampling efficiency, with lower wind speeds clearly associated with an increase in sampling efficiency.
The current convention for sampling inhalable aerosols was based on several mannequin studies performed in wind tunnels at wind speeds between 0.5 and 4 m s−1. In reality, as we now know, the wind speed in most modern indoor working environments is generally at or below ∼0.2 m s−1. Inhalability studies performed in calm air aerosol chambers have shown that human aspiration efficiency at essentially zero wind speed is not consistent with the existing inhalable aerosol convention, calling into question the universal applicability of the current standard. More recently, experiments were carried out in a new hybrid wind tunnel–calm air chamber at more representative workplace wind speeds, between ∼0.1 and 0.5 m s−1, to fill in this knowledge gap. Comparing these new data to both the existing inhalable aerosol convention and a recently proposed alternative for low wind movement suggests that, while the existing inhalable aerosol convention remains appropriate for wind speeds above ∼0.2 m s−1, the modified version is more appropriate for the range below ∼0.2 m s−1.
Increasing concern over air pollution has led to the development of low-cost sensors suitable for wide-scale deployment and use by citizen scientists. This project investigated the AirU low-cost particle sensor using two methods: (1) a comparison of pre- and post-deployment calibration equations for 24 devices following use in a field study, and (2) an in-home comparison between 3 AirUs and a reference instrument, the GRIMM 1.109. While differences (and therefore some sensor degradation) were found in the pre- and post-calibration equation comparison, absolute value changes were small and unlikely to affect the quality of results. Comparison tests found that while the AirU did tend to underestimate minimum and overestimate maximum concentrations of particulate matter, ~88% of results fell within ±1 μg/m3 of the GRIMM. While these tests confirm that low-cost sensors such as the AirU do experience some sensor degradation over multiple months of use, they remain a valuable tool for exposure assessment studies. Further work is needed to examine AirU performance in different environments for a comprehensive survey of capability, as well as to determine the source of sensor degradation.