We discuss the motion and structure of the magnetopause/boundary layer observed by Cluster in response to a joint tangential discontinuity/vortex sheet (TD/VS) observed by the Advanced Composition Explorer spacecraft on 7 December 2000. The observations are then supplemented by theory. Sharp polarity reversals in the east‐west components of the field and flow By and Vy occurred at the discontinuity. These rotations were followed by a period of strongly northward interplanetary magnetic field (IMF). These two factors elicited a two‐stage response at the magnetopause, as observed by Cluster situated in the boundary layer at the duskside terminator. First, the magnetopause suffered a large deformation from its equilibrium position, with large‐amplitude oscillations of ∼3‐min period being set up. These are argued to be mainly the result of tangential stresses associated with ΔVy the contribution of dynamic pressure changes being small in comparison. This strengthens recent evidence of the importance to magnetospheric dynamics of changes in azimuthal solar wind flow. The TD/VS impact caused a global response seen by ground magnetometers in a magnetic local time range spanning at least 12 h. The response monitored on ground magnetometers is similar to that brought about by magnetopause motions driven by dynamic pressure changes. Second, Cluster recorded higher‐frequency waves (∼79 s). Two clear phases could be distinguished from the spectral power density, which decreased by a factor of ∼3 in the second phase. Applying compressible linearized MHD theory, we show that these waves are generated by the Kelvin‐Helmholtz (KH) instability. Varying the local magnetic shear at the Cluster locale, as suggested by the temporal profile of the IMF clock angle, we find that locally stability was reinstated, so that the reduced power in the second phase is argued to be due residual KH activity arriving from locations farther to the dayside.
Simultaneous measurements of the magnetic-field distribution and the light intensity emitted by the current sheath (CS) generated in a Plasma Focus (PF) device are presented. For operating deuterium pressures in the range 0.55-2.5 mbar, we derive the plasma density and the mean hydrodynamic velocity in a frame of reference fixed to the sheath, where both quantities are in agreement with the ones predicted by the strong ionizing shock theory. The electric field in the quoted frame is also deduced, and the obtained values are consistent with those reported by other authors.
In this work, we present experimentally obtained limits for the values of the neutral copper gas electrical resistivity as a function of the temperature. When a current of about A or larger flows through a metallic wire in a microsecond or shorter time, the wire performs a phase change from solid to plasma, through intermediate states of metallic liquid and vapor. If the wire is surrounded by a non-conductive dense medium that inhibits the circulation of current outside the wire (e.g., air at room temperature and standard pressure, as in our experiments), the electric current stops when part of the metallic wire becomes gas. This process is known as dark pause, and it has a duration that depends on the experiment parameters. By means of a suitable choice of parameters, we achieved a duration of the dark pause of ≈1 s, which allowed us to determine the limits of the electrical resistivity of the metallic gas. The range of measured values starts from the resistivity of liquid copper at boiling temperature, and goes up to ≈0.01 Ohm·m at the maximum measured temperature.
Optical Doppler shift experiments are not simple because the light source cannot easily be moved in a sufficiently smooth and uniform manner to keep the level of noise well below that of the signal. Thus, most Doppler shift experiments are performed with sound or microwaves. Instead of using a moving mirror to produce a moving light source, we use a rotating mirror in which one beam is reflected from the advancing side and the other beam is reflected from the receding part of a rotating mirror. This arrangement can overcome many noise generating effects.