High energy heavy ions were generated in laser produced plasma at moderate laser energy, with a large focal spot size of 0.5 mm diameter. The laser beam was provided by the 10 GW GSI-NHELIX laser systems, and the ions were observed spectroscopically in status nascendi with high spatial and spectral resolution. Due to the focal geometry, plasma jet was formed, containing high energy heavy ions. The velocity distribution was measured via an observation of Doppler shifted characteristic transition lines. The observed energy of up to 3 MeV of F-ions deviates by an order of magnitude from the well-known Gitomer (Gitomer et al., 1986) scaling, and agrees with the higher energies of relativistic self focusing.
Dynamic stabilization of incompressible and immiscible Newtonian fluids is studied by means of an approximate analytical model that considers the vertical vibration of the interface between the fluids. The force driving the vibration is modeled by periodic sequences of Dirac deltas. The model shows the roles played by surface tension and viscosity in determining the stability boundaries and the relevant similarity parameters are found. The results are compared with previous theoretical and experimental studies that used a sinusoidal vibration and they are found to present the same qualitative features provided a symmetric sequence of Dirac deltas is considered. Instead, important differences are observed when an asymmetric driving is used.
An analytical model for the ablation driven by hot electrons is presented. The hot electrons are assumed to be generated during the high intensity laser spike used to produce the ignitor shock wave in the shock ignition driven inertial fusion concept, and to carry on the absorbed laser energy in its totality. Efficient energy coupling requires to keep the critical surface sufficiently close to the ablation front and this goal can be achieved for high laser intensities provided that the laser wavelength is short enough. Scaling laws for the ablation pressure and the other relevant magnitudes of the ablation cloud are found in terms of the laser and target parameters. The effect of the preformed plasma assembled by the compression pulse, previous to the ignitor, is also discussed. It is found that a minimum ratio between the compression and the ignitor pulses would be necessary for the adequate matching of the corresponding scale lengths.
Dynamic stabilization of Rayleigh–Taylor instability in an ablation front is studied by considering a modulation in the acceleration that consists of sequences of Dirac deltas. This allows obtaining explicit analytical expressions for the instability growth rate as well as for the boundaries of the stability region. As a general rule, it is found that it is possible to stabilize all wave numbers above a certain minimum value , but the requirements in the modulation amplitude and frequency become more exigent with smaller . The essential role of compressibility is phenomenologically addressed in order to find the constraint it imposes on the stability region. The results for some different wave forms of the acceleration modulation are also presented.
In this work, we present experimentally obtained limits for the values of the neutral copper gas electrical resistivity as a function of the temperature. When a current of about A or larger flows through a metallic wire in a microsecond or shorter time, the wire performs a phase change from solid to plasma, through intermediate states of metallic liquid and vapor. If the wire is surrounded by a non-conductive dense medium that inhibits the circulation of current outside the wire (e.g., air at room temperature and standard pressure, as in our experiments), the electric current stops when part of the metallic wire becomes gas. This process is known as dark pause, and it has a duration that depends on the experiment parameters. By means of a suitable choice of parameters, we achieved a duration of the dark pause of ≈1 s, which allowed us to determine the limits of the electrical resistivity of the metallic gas. The range of measured values starts from the resistivity of liquid copper at boiling temperature, and goes up to ≈0.01 Ohm·m at the maximum measured temperature.