Jonathan Cole

Dr. Jonathan Cole

Mechanical and Aerospace Engineering, Queen's University Belfast, Belfast, UK
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2002 in Medical Engineering & Physics
Verified
Journal Article
Closed access
JCJonathan Cole
Jonathan Cole
JWJ.K. Watterson
J.K. Watterson
MOM.J.G. O’rEilly
M.J.G. O’rEilly
Intimal hyperplasia at arterial bypass graft anastomoses is a major factor responsible for graft failure. A revised surgical technique, incorporating a Taylor vein patch into the distal anastomosis of PTFE grafts, results in a decrease in intimal hyperplasia and improved patency rates. Numerical simulations of pulsatile, non-Newtonian blood flow through life-like femorodistal bypass models have been performed to determine whether haemodynamic benefits arise from the modified geometry of the Taylor anastomosis. In a conventional bypass, the distal anastomotic flow exhibited considerable spatial and temporal variations. Steep spatial gradients in the shearing force acted along the floor during systole. The effect of the Taylor geometry was to reduce gradually the momentum of the blood approaching the junction. Thus, flow disturbances were abated, undesirable flow separation at the toe was diminished, and a less adverse floor shear stress distribution prevailed in that case. Intimal thickening should be alleviated at the toe in the Taylor model where separation is reduced, and where the thrombogenic graft surface is replaced with a vein patch. Intimal hyperplasia on the floor may be inhibited in the Taylor model due to more favourable shear stresses. The improved flow through the patched anastomosis should contribute to its enhanced performance.

6 September 2012 in European Journal of Engineering Education
Verified
Journal Article
Closed access
JCJonathan Cole
Jonathan Cole
Stephen SpenceStephen Spence
Stephen Spence
The authors have developed a first-year fluids course for a class of around 230 aerospace, civil and mechanical engineering students. This paper aims to show how the teaching and assessment methodology was applied to the challenge of a large class. The lectures featured formal teaching interspersed with active learning elements. Smaller group (about 25–30 students) tutorial classes involved student practice. A 10-minute test occurred in each tutorial during weeks 3–11. Each test was based on the previous week's lecture material and the marks contributed towards 20% of the course mark. A condition for passing the course was that a student must pass at least six of the nine tests. The assessment promoted student involvement with the course – tutorial attendance was greater and more uniform than previously and exam performance improved significantly. Students recognised that the assessment system was useful in encouraging continuous learning over the semester and building confidence.

9 September 2002 in Journal of Biomechanics
Verified
Journal Article
Closed access
JCJonathan Cole
Jonathan Cole
JWJ.K. Watterson
J.K. Watterson
MOM.J.G. O’reilly
M.J.G. O’reilly

16 October 2023 in International Journal for Students as Partners
Verified
Journal Article
Open access
PDF file
SSSarah Slates
Sarah Slates
Alison Cook-SatherAlison Cook-Sather
Alison Cook-Sather
SASima Aghakhani
Sima Aghakhani
AAAli Al-Humuzi
Ali Al-Humuzi
DADulce Alonso
Dulce Alonso
WZWei Zou
Wei Zou

25 August 2023 in Fluids
Verified
Journal Article
Open access
PDF file
MEMarcus S. Elliott
Marcus S. Elliott
JCJonathan Cole
Jonathan Cole
RBRoss Blair
Ross Blair
GMGary Menary
Gary Menary
A three-dimensional, transient computational fluid dynamics analysis was conducted on an idealised geometry of a coronary artery fitted with representative geometries of an Absorb bioresorbable vascular scaffold (BVS) or a Xience drug-eluting stent (DES) in order to identify and compare areas of disturbed flow and potential risk sites. A non-Newtonian viscosity model was used with a transient velocity boundary condition programmed with user-defined functions. At-risk areas were quantified in terms of several parameters linked to restenosis: wall shear stress, time-averaged wall shear stress, oscillatory shear index, particle residence time, and shear rate. Results indicated that 71% of the BVS stented surface area had time-averaged wall shear stress values under 0.4 Pa compared to 45% of the DES area. Additionally, high particle residence times were present in 23% and 8% of the BVS and DES areas, respectively, with risk areas identified as being more prominent in close proximity to crowns and link struts. These results suggest an increased risk for thrombosis and neointimal hyperplasia for the BVS compared to the DES, which is in agreement with the outcomes of clinical trials. It is intended that the results of this study may be used as a pre-clinical tool to aid in the design of bioresorbable coronary stents.

12 January 1998
Verified
Conference Paper
Closed access
JCJonathan Cole
Jonathan Cole
MGMark Gillan
Mark Gillan
SRS. Raghunathan
S. Raghunathan