Coronary stents for treating atherosclerosis are traditionally manufactured from metallic alloys. However, metal stents permanently reside in the body and may trigger undesirable immunological responses. Bioresorbable polymer stents can provide a temporary scaffold that resorbs once the artery heals but are mechanically inferior, requiring thicker struts for equivalent radial support, which may increase thrombosis risk. This study addresses the challenge of designing mechanically effective but sufficiently thin poly(L-lactic acid) stents through a computational approach that optimises material properties and stent geometry. Forty parametric stent designs were generated: cross-sectional area (post-dilation), foreshortening, stent-to-artery ratio and radial collapse pressure were evaluated computationally using finite element analysis. Response surface methodology was used to identify performance trade-offs by formulating relationships between design parameters and response variables. Multi-objective optimisation was used to identify suitable stent designs from approximated Pareto fronts and an optimal design is proposed that offers comparable performance to designs in clinical practice. In summary, a computational framework has been developed that has potential application in the design of high stiffness, thin strut polymeric stents.
1 October 2018 in Journal of the Mechanical Behavior of Biomedical Materials
The development of coronary stents from poly(L-lactic acid) requires knowledge of its mechanical properties and the effects of manufacturing processes on those properties. The effects of the biaxial stretching procedure on the mechanical and microstructural properties of poly(L-lactic acid) are hereby investigated. The mechanical properties were evaluated before and after biaxial stretching, with a Design of Experiments methodology employed to identify processing parameters that had the most significant effect on the elastic modulus and yield strength of the biaxially stretched sheets. Microstructural characterisation was performed using differential scanning calorimetry to evaluate crystallinity and thermal transitions of the biaxially stretched sheets. The results show that the mechanical properties of the stretched sheets are highly dependent on the extent of stretch ratio applied during processing; however, neither the elastic modulus nor yield strength are directly attributable to crystallinity, but are affected by the degree of amorphous orientation. The results of this study have the potential to be applied in the design of high stiffness, thin-strut polymeric expandable scaffolds for the application of coronary stents.
1 September 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Coronary stents for treating atherosclerosis are traditionally manufactured from metallic alloys. However, metal stents permanently reside in the body and may trigger undesirable immunological responses. Bioresorbable polymer stents can provide a temporary scaffold that resorbs once the artery heals but are mechanically inferior, requiring thicker struts for equivalent radial support, which may increase thrombosis risk. This study addresses the challenge of designing mechanically effective but sufficiently thin poly(L-lactic acid) stents through a computational approach that optimises material properties and stent geometry. Forty parametric stent designs were generated: cross-sectional area (post-dilation), foreshortening, stent-to-artery ratio and radial collapse pressure were evaluated computationally using finite element analysis. Response surface methodology was used to identify performance trade-offs by formulating relationships between design parameters and response variables. Multi-objective optimisation was used to identify suitable stent designs from approximated Pareto fronts and an optimal design is proposed that offers comparable performance to designs in clinical practice. In summary, a computational framework has been developed that has potential application in the design of high stiffness, thin strut polymeric stents that contend with the performance of their metallic counterparts.
A three-dimensional, transient computational fluid dynamics analysis was conducted on an idealised geometry of a coronary artery fitted with representative geometries of an Absorb bioresorbable vascular scaffold (BVS) or a Xience drug-eluting stent (DES) in order to identify and compare areas of disturbed flow and potential risk sites. A non-Newtonian viscosity model was used with a transient velocity boundary condition programmed with user-defined functions. At-risk areas were quantified in terms of several parameters linked to restenosis: wall shear stress, time-averaged wall shear stress, oscillatory shear index, particle residence time, and shear rate. Results indicated that 71% of the BVS stented surface area had time-averaged wall shear stress values under 0.4 Pa compared to 45% of the DES area. Additionally, high particle residence times were present in 23% and 8% of the BVS and DES areas, respectively, with risk areas identified as being more prominent in close proximity to crowns and link struts. These results suggest an increased risk for thrombosis and neointimal hyperplasia for the BVS compared to the DES, which is in agreement with the outcomes of clinical trials. It is intended that the results of this study may be used as a pre-clinical tool to aid in the design of bioresorbable coronary stents.