Zhanying Wang

Zhanying Wang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
SSShuzheng Shi
Shuzheng Shi
Liyong MaLiyong Ma
Liyong Ma
KKKai Kang
Kai Kang
JZJie Zhu
Jie Zhu
Jin jiang HuJin jiang Hu
Jin jiang Hu
ZWZhanying Wang
Zhanying Wang
In response to the growing demand for high-sensitivity accelerometers in vector hydrophones, a piezoelectric MEMS accelerometer (PMA) was proposed, which has a four-cantilever beam integrated inertial mass unit structure, with the advantages of being lightweight and highly sensitive. A theoretical energy harvesting model was established for the piezoelectric cantilever beam, and the geometric dimensions and structure of the microdevice were optimized to meet the vibration pickup conditions. The sol-gel and annealing technology was employed to prepare high-quality PZT thin films on silicon substrate, and accelerometer microdevices were manufactured by using MEMS technology. Furthermore, the MEMS accelerometer was packaged for testing on a vibration measuring platform. Test results show that the PMA has a resonant frequency of 2300 Hz. In addition, there is a good linear relationship between the input acceleration and the output voltage, with V = 8.412a − 0.212. The PMA not only has high sensitivity, but also has outstanding anti-interference ability. The accelerometer structure was integrated into a vector hydrophone for testing in a calibration system. The results show that the piezoelectric vector hydrophone (PVH) has a sensitivity of –178.99 dB@1000 Hz (0 dB = 1 V/μPa) and a bandwidth of 20~1100 Hz. Meanwhile, it exhibits a good “8” shape directivity and consistency of each channel. These results demonstrate that the piezoelectric MEMS accelerometer has excellent capabilities suitable for use in vector hydrophones.

14 April 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
SSShuzheng Shi
Shuzheng Shi
XZXiaoyong Zhang
Xiaoyong Zhang
ZWZhanying Wang
Zhanying Wang
Liyong MaLiyong Ma
Liyong Ma
KKKai Kang
Kai Kang
Jin jiang HuJin jiang Hu
Jin jiang Hu
High-performance vector hydrophones have been gaining attention for underwater target-monitoring applications. Nevertheless, there exists the mutual constraint between sensitivity and bandwidth of a single hydrophone. To solve this problem, a four-unit array piezoelectric bionic MEMS vector hydrophone (FPVH) was developed in this paper, which has a cross-beam and a bionic fish-lateral-line-nerve-cell-cilia unit array structure. Simulation analysis and optimization in the design of the bionic microstructure have been performed by COMSOL 6.1 software to determine the structure dimensions and the lead zirconate titanate (PZT) thin film distribution. The FPVH was manufactured using MEMS technology and tested in a standing wave bucket. The results indicate that the FPVH has a sensitivity of up to −167.93 dB@1000 Hz (0 dB = 1 V/μPa), which is 12 dB higher than that of the one-unit piezoelectric MEMS vector hydrophone (OPVH). Additionally, the working bandwidth of the FPVH reaches 20 Hz~1200 Hz, exhibiting a good cosine curve with an 8-shape. This work paves a new way for the development of multi-unit piezoelectric vector hydrophones for underwater acoustic detectors.