Elif Yiğit

Dr. Elif Yiğit

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2023 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
GEGülbahar Erdinç
Gülbahar Erdinç
EYElif Yiğit
Elif Yiğit

Verified
Journal Article
Open access
PDF file
EYElif Yiğit
Elif Yiğit
HEHamiyet Güngör Erdoğan
Hamiyet Güngör Erdoğan
Tan Fırat EyüboğluTan Fırat Eyüboğlu
Tan Fırat Eyüboğlu
Mutlu ÖzcanMutlu Özcan
Mutlu Özcan
(1) Background: The purpose of this study was to determine the effect of commonly consumed beverages on the bond strength of three different computer-aided design-computer-aided manufacturing (CAD/CAM) resin–ceramic hybrid materials repaired with resin-based composite (RBC) materials. (2) Materials and Methods: Rectangular prism specimens (N = 138) measuring 6 mm × 5 mm × 2 mm were obtained from GC Cerasmart (GC), Lava Ultimate (LU), and Vita Enamic (VE) blocks. These blocks were polished and then subjected to thermal cycling (10,000 cycles, 5 °C to 55 °C). After the surface treatment was applied, the average surface roughness value was measured. All the surfaces were repaired with RBC. Thermal cycling was performed for the second time. Each group was then distributed into three subgroups according to the beverage used: tea (t), cola (c), and distilled water (0) (n = 15). The specimens were stored in these solutions for 28 days and then subjected to the shear bond strength (SBS) test. Statistical analysis was performed using a two-way ANOVA test with Bonferroni adjustment. (3) Results: The surface roughness of the materials presented no significant difference after different surface treatments (p > 0.05). No significant difference was observed among the materials (p > 0.05). Tea and cola presented similar SBS values (p > 0.05). Both were significantly lower than distilled water (p < 0.001, p < 0.001, respectively). (4) Conclusions: Consumption of beverages reduces the bond strength in surfaces repaired with RBC to CAD/CAM resin–ceramic hybrid materials. (5) Clinical Significance: Repairing damaged resin matrix dental restorations with RBC is advantageous in terms of time and cost by achieving adequate bond strengths. Frequently consumed beverages reduce the bond strength of repaired CAD/CAM resin–ceramic hybrid materials.

1 January 2025 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
EYElif Yiğit
Elif Yiğit
VŞVolkan Şahin
Volkan Şahin
Yiğit E, et al. J Adv Prosthodont. 2025 Aug;17(4):210-223. https://doi.org/10.4047/jap.2025.17.4.210

30 April 2026 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
EYElif Yiğit
Elif Yiğit
NÖNihal Özcan
Nihal Özcan
VŞVolkan Şahin
Volkan Şahin
This finite element analysis (FEA) aimed to evaluate the biomechanical behavior of all-on-four implant-supported full-arch prostheses fabricated from diffe

26 May 2026 in European Journal of Dental Education
Verified
Journal Article
Open access
EYElif Yiğit
Elif Yiğit
SASaadet Atsü
Saadet Atsü
Objective: This study examines differences in scores assigned to dental students' assignments when evaluated by two instructors and compares assessments conducted with a structured preclinical assessment form versus those without one. Materials and Methods: In this study, two instructors independently evaluated 50 die model assignments prepared by third‐year dental students. Each instructor assessed the same assignment using two methods: With a structured preclinical assessment form and without one. The obtained scores were compared for consistency between instructors and within the same instructor across different evaluation methods. The data were analysed using a paired t ‐test and intraclass correlation coefficients (ICC). The level of statistical significance was set at p < 0.05. Results: Significant differences were observed both between instructors and within one instructor when different assessment methods were applied. For the junior specialist, a statistically significant difference was found between evaluations conducted with and without the structured preclinical assessment form ( p < 0.001), with higher scores observed when the form was used. However, no statistically significant difference was found between the two assessment methods for the senior specialist. Furthermore, inter‐rater comparison revealed no statistically significant difference in scores when the unstructured method was used ( p = 0.053). In contrast, the use of the structured preclinical assessment form resulted in a statistically significant difference among evaluators ( p < 0.001). Inter‐rater reliability was moderate with the structured form (ICC = 0.51) and lower with the unstructured method (ICC = 0.41). Conclusion: Although the use of a structured preclinical assessment form did not eliminate inconsistencies between instructors, it revealed discrepancies associated with different evaluation methods. These findings underscore the importance of calibration and structured implementation to improve consistency in dental education assessment.

31 December 2023 in International Journal of 3D Printing Technologies and Digital Industry
Verified
Journal Article
Open access
PDF file
EYElif Yiğit
Elif Yiğit
HBH.Sevilay BAHADIR
H.Sevilay BAHADIR
ABAli Can Bulut
Ali Can Bulut
Bu çalışmanın hedefi, üç boyutlu (3B) yazıcı sistemi kullanılarak üretilen inley restorasyonlarının siman aralığı değerlerini araştırmaktır.Bu çalışma kapsamında, toplamda 60 adet typodont diş kullanıldı. Bu dişlerin yarısı (n=15), mesio-oklüzal (MO) kaviteler için, kalan yarısı (n=15) ise mesio-oklüzal-distal (MOD) kaviteler oluşturmak için kullanıldı. Bukkolingual genişlik 2,5-3mm ve pulpal derinlik 2mm olacak şekilde okluzal kaviteler hazırlandı. Proksimal inley kaviteler, basamak derinliği 1,5mm ve basamak kalınlığı 1 mm, bukkolingual genişliği 5 mm olarak tasarlandı. Kaviteler, intraoral dijital tarayıcı (TRIOS 3 Basic, Kopenhag, Danimarka) kullanılarak tarandı ve EXOCAD (Exocad Dental CAD 2.2, Darmstadt, Almanya) yazılımıyla inley restorasyon tasarımları yapıldı. 3B yazıcı (Phrozen sonic mini 4K SLA cihazı, Hsinchu, Tayvan) ile restorasyonların üretimi yapıldı. Restorasyonların siman aralığı değerlendirmek için silikon replika yöntemi kullanıldı ve kesitler stereomikroskop altında x10 büyütmede incelendi. Ölçümler üç farklı noktadan yapılıp, analiz için Adobe Photoshop programı kullanıldı. SPSS 22.0 programında Pairwise-Comparisons ve Kruskal-Wallis testleri ile verilerin analizi yapıldı (α