Mohamed Abdalla Moawad

Dr. Mohamed Abdalla Moawad

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

14 October 2021 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Closed access
PDF file
MOM. A. Othman
M. A. Othman
HEHesham Elemam
Hesham Elemam
MSM. H. Seleem
M. H. Seleem
Hossam El-Din M. SallamHossam El-Din M. Sallam
Hossam El-Din M. Sallam
MMMohamed Abdalla Moawad
Mohamed Abdalla Moawad

25 July 2022 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Open access
PDF file
MHM. A. Hussien
M. A. Hussien
MMMohamed Abdalla Moawad
Mohamed Abdalla Moawad
MSM. H. Seleem
M. H. Seleem
Hossam El-Din M. SallamHossam El-Din M. Sallam
Hossam El-Din M. Sallam
HEHesham Elemam
Hesham Elemam
Unfortunately, fibrous composite materials' mixed-mode fracture toughness (K eff ) was measured using inappropriate through-thickness cracked (TTC) specimens. The problem with such specimens is the ignorance of the fibers in the pre-notch surfaces, i.e., no fiber bridging behind the crack tip. In the present paper, a real K eff of fiber-reinforced concrete (FRC) was experimentally determined using matrix cracked (MC) specimens. Traditional (TTC) specimens were also adopted for comparison. The effect of fiber length (35 mm, 50 mm, and hybrid fibers, 50% from each length) and mode of mixity (M e ), M e = 0, 1/4, and 1/2 were studied. Hooked end steel fibers of a volume fraction equal to 1% were used. All cracked beams with a crack-length-to-beam-depth ratio equal to 0.3 were tested under three-point bending in mode I and mixed-mode. The span/depth ratio was equal to two for all specimens. Since there is no equation to predict the K eff of MC specimens and the inapplicability of Griffith's theory to predict the K eff due to the difference in crack paths, new realistic procedures were suggested to overcome this dilemma. The results indicated that MC specimens recorded a lower crack initiation load than the peak load. In contrast, the crack initiation load coincides with the peak load in the case of TTC specimens. This reflected the role of steel fibers behind the crack tip in retarding the specimens to reach their ultimate capacity after crack initiation. K eff increased with increasing M e . Although long fibers recorded higher peak load and energy, their effect on K eff of MC FRC specimens was marginal due to the minor effect of fiber length on the crack initiation loads. The MC specimen is a realistic approach for estimating the K eff of FRC.

7 August 2023 in Buildings
Verified
Journal Article
Open access
PDF file
MAMahmoud Abdallah
Mahmoud Abdallah
AEAhmed Ali Elakhras
Ahmed Ali Elakhras
RRRamy M Reda
Ramy M Reda
Hossam El-Din M. SallamHossam El-Din M. Sallam
Hossam El-Din M. Sallam
MMMohamed Abdalla Moawad
Mohamed Abdalla Moawad
Unfortunately, most of the previous work studying the fracture toughness of fibrous composites has deliberately ignored bridging the fiber onto the pre-crack/notch surfaces by creating such a crack as a through-thickness crack (TTC). Furthermore, no standard specifications for measuring the fracture toughness of fibrous composites have considered the fiber bridging through the pre-notch. Only a few pieces of research, no more than fingers on one hand, have addressed this problem by creating an actual crack, i.e., a matrix crack (MC) instead of a TTC. The challenge these researchers face is the inability to calculate the fracture toughness directly through the stress intensity factor (SIF) relationship because there is no geometry correction factor equation, f(a/d), for an MC. The main objective of the present work is to calculate f(a/d) and ascertain a relationship between the SIF and crack mouth opening displacement (CMOD) for an MC numerically using 3-D finite element analysis. An experimental program was also conducted to measure the fracture toughness of three types of concrete beams: high-strength concrete (HSC) beams with a TTC, HSC beams with an MC, and fiber-reinforced concrete (FRC) beams with an MC. The results showed that FRC beams with an MC have the highest fracture toughness and, subsequently, the highest resistance to crack growth. The numerical results revealed a suggested relationship between the SIF and CMOD of FRC beams with an MC. This relation was used to predict the fracture toughness of FRC with an MC by the critical value of CMOD measured experimentally.

7 November 2024 in Fracture and Structural Integrity
Verified
Journal Article
Open access
PDF file
Seleem S.E AhmadSeleem S.E Ahmad
Seleem S.E Ahmad
YEYasmine Elmenshawy
Yasmine Elmenshawy
YGYasser Osman El Gammal
Yasser Osman El Gammal
HEHamees Mohamad El-Sheikh
Hamees Mohamad El-Sheikh
MMMohamed Abdalla Moawad
Mohamed Abdalla Moawad
MEMohamed Ahmed Refat El-Mahdy
Mohamed Ahmed Refat El-Mahdy
Concrete completely submerged in sulfate solutions has been used as the primary study subject for the durability of concrete subjected to sulfates. On the other hand, empirical data from the field indicates that concrete exposed to sulfates may exhibit physical attack-induced surface scaling above. This study aims to study the two different types of local bacteria, (BS) and (BM), with content of 0%, 0.25%, 1%, 2.50%, and 5.00% by cement weight used in this work under curing in sulfate to examine the efficiency of bacterial self-healing of cracks for sustainable concrete in aggressive sulfate attack environments. The results show that in both curing in freshwater, FW, and sulfate, SUL, the optimum bacteria ratio was 2.5% BM, and the compressive strength improved by 43.34% for FW and 47.65% for sulfate. On the other hand, the results proved that the crack-filling and crack-repairing methods may be considered quicker than conventional methods. Moreover, a detailed conclusion about the preparation and processing of bacteria to provide the most significant content of locally accessible bacteria in Egypt, mainly when using chemical and mineral additives.

1 January 2022 in Engineering Research Journal - Faculty of Engineering (Shoubra)
Verified
Journal Article
Open access
PDF file
RMRashed M.ALmari
Rashed M.ALmari
MAMohamed Abdelrahman
Mohamed Abdelrahman
MMMohamed Abdalla Moawad
Mohamed Abdalla Moawad
A latent heat storage tank with a helical coil heat exchanger was developed, built, connected to an evacuated tube solar collector, and tested in this study. 25 kg of paraffin wax was used as phase change material (PCM) in the storage tank. During the charging (melting) process, the storage system was evaluated with varied mass flow rates of hot water as a heat transfer medium (5, 8, 9, 10.5 and 13 L/min). The system was also tested with a constant mass flow rate of domestic water during the discharging cycle (solidification). The results also showed that increasing the flow rate from 5 L/min to 13 L/min reduced the charging time from 218 min to 157 min and increased the system's overall efficiency from 28.4 % to 40.5 %.