Kuan LI

Dr. Kuan LI


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2019 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
KLKuan LI
Kuan LI
WZWanjie Zhang
Wanjie Zhang
HWHong Wang
Hong Wang
YLYudun Li
Yudun Li
MLMeng Liu
Meng Liu
The online identification of subsynchronous oscillation (SSO) became possible with a wide application of wide area measurement system. However, there is more power electronic equipment in the power system. So, there are strong interference noises in the sampled signal, and the veracity of vibration modal parameters is influenced. The fast independent component analysis (FastICA) could separate noise signal from the observed signal. This study presented the pretreatment of sampling signal through the FastICA and the identification of the SSO parameter through matrix pencil (MP). The recognition accuracy could be enhanced based on FastICA–MP. This study sets the ideal example and the IEEE first benchmark model as the simulation examples. The simulation results show that the FastICA could separate noise signal effectively, and the MP identification accuracy is improved. The research result lays the foundations for the design of supplementary subsynchronous damping controller.

1 February 2018 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
KLKuan LI
Kuan LI
MLMeng Liu
Meng Liu
WZWei Zheng
Wei Zheng
YLYudun Li
Yudun Li
XWXin Wang
Xin Wang
Utilization of photovoltaic power generation has attracted considerable attention, and it is growing rapidly due to its environmental benefits. The series capacitive compensation is needed to be introduced into the lines which could improve the transmission capacity. However, the series capacitive compensation may lead to sub-synchronous resonance(SSR). This paper proposes a method to restrain the SSR based on photovoltaic grid connected which is caused by series capacitive compensation. Sub-synchronous oscillation damping controller (SSDC) is designed based on complex torque coefficient approach, and the SSDC is added to the PV power station's main controller to damp SSR. IEEE Second benchmark model is used as simulation model based on PSCAD/EMTDC. The results show that the designed SSDC could restrain SSR and improve stability in PV grid connected effectively.

9 June 2026 in Electronics
Verified
Journal Article
Open access
PDF file
WYWenliang Yin
Wenliang Yin
YLYudun Li
Yudun Li
KLKuan LI
Kuan LI
MLMaozeng Lu
Maozeng Lu
With the increasing penetration of distributed renewable energy, distribution networks face severe operational challenges during grid faults, where rapid power restoration and system stability are crucial. Traditional fault restoration strategies often rely on static dynamic zoning or simple power balancing, neglecting the critical electrical interactions among nodes. To address these limitations, this paper innovatively proposes a hierarchical coordinated control framework for distribution network fault recovery, combining dynamic zoning and coordinated load shedding. The core novelty of this research lies in integrating the node electrical correlation degree into the load grading process to assist in coordinating dynamic network dynamic zoning. By comprehensively evaluating real-time power flow, the regulation capabilities of distributed resources, and intra-region electrical correlations, the proposed framework adaptively optimizes both the zoning structure and the load shedding sequence. Simulation results demonstrate that, compared with conventional static or uncoordinated methods, the proposed approach significantly minimizes load loss while improving grid recovery efficiency and voltage stability. Ultimately, this coordinated control strategy effectively enhances the resilience and operational safety of high-penetration renewable distribution networks, providing robust support for distribution network operations under a high proportion of renewable energy integration.

6 August 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
KLKuan LI
Kuan LI
YLYudun Li
Yudun Li
GZGuohui Zhang
Guohui Zhang
KSKongming Sun
Kongming Sun
YHYanqi Hou
Yanqi Hou
Industrial microgrids are emerging as important providers of demand-side flexibility for active distribution networks. However, their participation in source–load coordination is hindered by complex production constraints, limited dispatch executability, and the widespread reliance on baseline-based demand response mechanisms. To address these challenges, this paper proposes a baseline-free source–load coordination framework for industrial microgrid clusters. A linear state–task network (LSTN) model is employed to characterize industrial production processes while preserving equipment operation, material balance, buffer storage, and production target constraints. Based on the feasible operating regions of individual microgrids, a simplified optimal adjustable load model (OALM) is developed at the aggregator level to identify and aggregate cluster-level flexibility boundaries without disclosing detailed production information. Building upon the aggregated flexibility region, a baseline-free target power tracking strategy is established, in which the distribution network issues absolute power targets and the aggregator coordinates multiple industrial microgrids to achieve their realization. The proposed framework simultaneously ensures production feasibility, scalable flexibility aggregation, and practical dispatch implementation. Case studies demonstrate that the aggregated industrial load can accurately track dispatch targets while satisfying all production constraints, thereby enhancing the capability of industrial microgrid clusters to participate in large-scale source–load interaction and renewable energy accommodation. Case study results show that when the number of industrial microgrids increases from 10 to 200, the total computation time increases from 5.08 s to 337.40 s, while the target tracking error remains within numerical tolerance. Compared with the conventional baseline-based virtual-battery (VB) method, whose root mean square error (RMSE) with respect to the intended absolute target reaches 241.30 kW under a ±10% baseline estimation error, the proposed method achieves near-zero tracking error. In addition, the production-agnostic aggregation model expands the flexibility boundary by 21.84% and generates targets that are not exactly executable under the full LSTN production constraints.

5 November 2026 in Electronics
Verified
Journal Article
Open access
PDF file
KLKuan LI
Kuan LI
YHYanqi Hou
Yanqi Hou
YLYudun Li
Yudun Li
KSKongming Sun
Kongming Sun
TLTongyu Liu
Tongyu Liu
Synchronized fixed-frequency current control (SFFC) enables inverter-dominated islanded microgrids to regulate power without relying on frequency deviations. However, conventional SFFC may exhibit power oscillations when battery storage systems (BSSs) transition from discharging to charging, while unbalanced and nonlinear loads can degrade voltage quality. To address these challenges, this paper proposes an improved SFFC scheme integrating power decoupling, multi-frequency voltage compensation, and current-capacity coordination. First, the mechanism of power oscillations during BSS discharging-to-charging transitions is analyzed, and a voltage-vector-oriented controller is developed to decouple active- and reactive-power regulation. Second, the effects of negative-sequence and harmonic currents on voltage distortion are analyzed while considering the inverter equivalent impedance. Accordingly, a compensation method combining notch and low-pass filters is developed to extract and compensate for the fundamental negative-sequence and selected harmonic components. Third, a residual-current-capacity-based allocation strategy is developed to coordinate reactive-power support, negative-sequence voltage compensation, and harmonic suppression within inverter current limits. Furthermore, a satellite-synchronized mode-transition strategy is incorporated to facilitate transitions between grid-connected and islanded operation. Simulation and experimental results demonstrate improved power regulation and voltage quality under different operating conditions. Specifically, the experimental line-voltage unbalance index decreases from 3.83% to 1.64%, while the line-voltage total harmonic distortion decreases from 4.89% to 1.98%. Stable BSS charging and discharging operation and grid-connected-to-islanded transitions are also experimentally demonstrated.