Deep neutral networks (DNNs) are complex machine learning models designed for decision-making tasks with high accuracy. However, DNNs require high computational power and memory, which limits such models to fitting on edge devices, resulting in unnecessary processing delays and high energy consumption. Graphical processing units (GPUs) offer reliable hardware acceleration, but their bulky sizes prevent their utilization in portable equipment. System-on-chip field programmable gated arrays (SoC-FPGAs) provide considerable computational power with low energy consumption, making them ideal for edge computing applications, owing to their innovative, flexible, and small design. In this paper, we implement a deep-learning-based music genre classification system on a SoC-FPGA board, evaluate the model’s performance, and provide a comparative analysis across different platforms. Specifically, we compare the performance of long short-term memory (LSTM), convolutional neural networks (CNNs), and a hybrid model (CNN-LSTM) on an Intel Core i7-8550U by Intel Cooperation. The models are fed an acoustic feature called the Mel-frequency cepstral coefficient (MFCC) for training and testing (inference). Then, by using the advanced Vitis AI tool, a deployable version of the model is generated. The experimental results show that the execution speed is increased by 80%, and the throughput rises four times when the CNN-based music genre classification system is implemented on SoC-FPGA.
For bradycardic patients after cardiac surgery, it is unknown how long to wait before implanting a permanent pacemaker (PPM). Current recommendations vary and are based on observational studies. This study aims to examine why this variation may exist. We conducted first a study of patients in our institution and second a systematic review of studies examining conduction disturbance and pacing after cardiac surgery. Of 5849 operations over a 6-year period, 103 (1.8%) patients required PPM implantation. Only pacing dependence at implant and time from surgery to implant were associated with 30-day pacing dependence. The only predictor of regression of pacing dependence was time from surgery to implant. We then applied the conventional procedure of receiver operating characteristic (ROC) analysis, seeking an optimal time point for decision-making. This suggested the optimal waiting time was 12.5 days for predicting pacing dependence at 30 days for all patients (area under the ROC curve (AUC) 0.620, P = 0.031) and for predicting regression of pacing dependence in patients who were pacing-dependent at implant (AUC 0.769, P < 0.001). However, our systematic review showed that recommended optimal decision-making time points were strongly correlated with the average implant time point of those individual studies (R = 0.96, P < 0.001). We further conducted modelling which revealed that in any such study, the ROC method is strongly biased to indicate a value near to the median time to implant as optimal. When commonly used automated statistical methods are applied to observational data with the aim of defining the optimal time to pacing after cardiac surgery, the suggested answer is likely to be similar to the average time to pacing in that cohort.
Cardiovascular diseases (CVDs) are the leading cause of mortality worldwide. Recent advancements in machine learning have significantly enhanced early detection and treatment strategies for CVDs. While electrocardiogram (ECG) signals are commonly used for detection, additional signals like arterial blood pressure (ABP) and central venous pressure (CVP) provide a comprehensive view of the cardiovascular system. However, acquiring such extensive datasets is challenging due to resource constraints, privacy issues, and ethical considerations. This paper introduces a novel Multichannel Conditional Wasserstein Generative Adversarial Network (MC-WGAN) capable of simultaneously generating synthetic ECG, ABP, and CVP signals. The MC-WGAN model addresses the data scarcity issue by providing high-fidelity synthetic data that mirrors real physiological signals, facilitating better simulation, diagnosis, and treatment planning. Evaluation against the MIT-BIH Arrhythmia Database demonstrated the model’s strong performance, with competitive metrics such as RMSE, PRD, and FD, particularly excelling in the generation of ECG and ABP signals. MC-WGAN surpasses other generative models by simultaneously replicating multiple physiological signals, offering a comprehensive view of cardiovascular health. This advancement enhances diagnostic accuracy and risk stratification, setting a new standard in synthetic biomedical signal generation, and paving the way for more personalized and effective clinical interventions.
Our group has shown that central venous pressure (CVP) can optimise atrioventricular (AV) delay in temporary pacing (TP) after cardiac surgery. However, the signal-to-noise ratio (SNR) is influenced both by the methods used to mitigate the pressure effects of respiration and the number of heartbeats analysed. This paper systematically studies the effect of different analysis methods on SNR to maximise the accuracy of this technique. We optimised AV delay in 16 patients with TP after cardiac surgery. Transitioning rapidly and repeatedly from a reference AV delay to different tested AV delays, we measured pressure differences before and after each transition. We analysed the resultant signals in different ways with the aim of maximising the SNR: (1) adjusting averaging window location (around versus after transition), (2) modifying window length (heartbeats analysed), and (3) applying different signal filtering methods to correct respiratory artefact. (1) The SNR was 27 % higher for averaging windows around the transition versus post-transition windows. (2) The optimal window length for CVP analysis was two respiratory cycle lengths versus one respiratory cycle length for optimising SNR for arterial blood pressure (ABP) signals. (3) Filtering with discrete wavelet transform improved SNR by 62 % for CVP measurements. When applying the optimal window length and filtering techniques, the correlation between ABP and CVP peak optima exceeded that of a single cycle length (R = 0.71 vs. R = 0.50, p < 0.001). We demonstrated that utilising a specific set of techniques maximises the signal-to-noise ratio and hence the utility of this technique.
1 January 2023 in Journal of Biomedical Engineering and Biosciences