Jie Xia

Ms. Jie Xia

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
BLBoyu Li
Boyu Li
LLLi Li
Li Li
JXJie Xia
Jie Xia
Hao JinHao Jin
Hao Jin
Shurong DongShurong Dong
Shurong Dong
Jikui LuoJikui Luo
Jikui Luo
Synchronous monitoring electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) have received significant attention in brain science research for their provision of more information on neuro-loop interactions. There is a need for an integrated hybrid EEG-fNIRS patch to synchronously monitor surface EEG and deep brain fNIRS signals. Here, we developed a hybrid EEG-fNIRS patch capable of acquiring high-quality, co-located EEG and fNIRS signals. This patch is wearable and provides easy cognition and emotion detection, while reducing the spatial interference and signal crosstalk by integration, which leads to high spatial–temporal correspondence and signal quality. The modular design of the EEG-fNIRS acquisition unit and optimized mechanical design enables the patch to obtain EEG and fNIRS signals at the same location and eliminates spatial interference. The EEG pre-amplifier on the electrode side effectively improves the acquisition of weak EEG signals and significantly reduces input noise to 0.9 μVrms, amplitude distortion to less than 2%, and frequency distortion to less than 1%. Detrending, motion correction algorithms, and band-pass filtering were used to remove physiological noise, baseline drift, and motion artifacts from the fNIRS signal. A high fNIRS source switching frequency configuration above 100 Hz improves crosstalk suppression between fNIRS and EEG signals. The Stroop task was carried out to verify its performance; the patch can acquire event-related potentials and hemodynamic information associated with cognition in the prefrontal area.

23 January 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
JXJie Xia
Jie Xia
FZFan Zhang
Fan Zhang
LZLuxi Zhang
Luxi Zhang
ZCZhen Cao
Zhen Cao
Shurong DongShurong Dong
Shurong Dong
GZGuodong Zhou
Guodong Zhou
Advancements in brain–machine interfaces and neurological treatments urgently require the development of improved brain electrodes applied for long-term implantation, where traditional and polymer options face challenges like size, tissue damage, and signal quality. Carbon nanotubes are emerging as a promising alternative, combining excellent electronic properties and biocompatibility, which ensure better neuron coupling and stable signal acquisition. In this study, a new flexible brain electrode array based on 99.99% purity of single-walled carbon nanotubes (SWCNTs) was developed, which has 30 um × 40 um size, about 5.1 kΩ impedance, and 14.01 dB signal-to-noise ratio (SNR). The long-term implantation experiment in vivo in mice shows the proposed brain electrode can maintain stable LFP signal acquisition over 12 weeks while still achieving an SNR of 3.52 dB. The histological analysis results show that SWCNT-based brain electrodes induced minimal tissue damage and showed significantly reduced glial cell responses compared to platinum wire electrodes. Long-term stability comes from SWCNT’s biocompatibility and chemical inertness, the electrode’s flexible and fine structure. Furthermore, the new brain electrode array can function effectively during 7-Tesla magnetic resonance imaging, enabling the collection of local field potential and even epileptic discharges during the magnetic scan. This study provides a comprehensive study of carbon nanotubes as invasive brain electrodes, providing a new path to address the challenge of long-term brain electrode implantation.

17 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
SWShengming Wang
Shengming Wang
LYLuoqi Yang
Luoqi Yang
HJHaofei Jiang
Haofei Jiang
JXJie Xia
Jie Xia
WLWenjuan Li
Wenjuan Li
ZXZhenwei Xie
Zhenwei Xie
The pelvic floor dysfunction (PFD) has become a serious public health problem. Accurate diagnosis of regional pelvic floor muscle (PFM) malfunctions is vitally important for the prevention and treatment of PFD. However, there is a lack of reliable diagnostic devices to evaluate and diagnose regional PFM abnormality. In this work, we developed a multifunctional evaluation technology (MET) based on a novel airbag-type stretchable electrode array probe (ASEA) for the diagnosis of malfunctions of regional PFM. The inflatable ASEA has specifically distributed 32 electrodes along the muscles, and is able to adapt to different human bodies for tight contact with the muscles. These allow synchronous collection of high-quality multi-channel surface electromyography (MC-sEMG) signals, and then are used to diagnose regional PFM malfunctions and evaluate inter-regional correlation. Clinical trial was conducted on 15 postpartum stress urinary incontinence (PSUI) patients and 15 matched asymptomatic women. Results showed that SUI patients responded slowly to the command and have symptoms of muscle strength degeneration. The results were consistent with the relevant clinical manifestations, and proved the reliability of MET for multifunctional PFM evaluation. Furthermore, the MET can diagnose malfunctions of regional PFM, which is inaccessible with existing technology. The results also showed that the dysfunction of PSUI patients is mainly located in iliococcygeus, pubococcygeus, and urethral sphincter regions, and there is a weak correlation between these specific regions and nearby regions. In conclusion, MET provides a point-of-care diagnostic method for abnormal function of regional PFM, which has a potential for the targeted point-to-point electrical stimulation treatment and PFD pathology research.

26 September 2025 in Science Advances
Verified
Journal Article
Open access
LZLuxi Zhang
Luxi Zhang
SWShengming Wang
Shengming Wang
JXJie Xia
Jie Xia
BLBoyu Li
Boyu Li
Sameul ZhangSameul Zhang
Sameul Zhang
Shurong DongShurong Dong
Shurong Dong
Long-term implantable neural probes with dual-mode optical stimulation and simultaneous electrical recording are crucial for modulating neural loop activity in vivo. Traditional probes using “add-on” strategies often suffer from mechanical rigidity, compromised electrical performance, and insufficient biocompatibility, limiting their clinical applicability. In this study, we present a method for the direct laser writing of electrode arrays onto the curved surface of optical fibers, integrating them within a biocompatible polymer coating to create monolithic neural probes. The monolithic probes demonstrate high mechanical bending endurance, stable impedance, and improved biocompatibility, resulting in a lower inflammatory response compared to conventional systems. Furthermore, our method facilitates the multilayer integration of multilayer electrodes onto optical fibers, enabling high-density electrical readout channels. This advancement represents substantial progress in neuroengineering, with promising implications for future neural monitoring and modulation applications.

29 August 2023 in Electronics
Verified
Journal Article
Open access
PDF file
JPjiadong pan
jiadong pan
JXJie Xia
Jie Xia
FZFan Zhang
Fan Zhang
LZLuxi Zhang
Luxi Zhang
Sameul ZhangSameul Zhang
Sameul Zhang
Shurong DongShurong Dong
Shurong Dong
This paper developed a comprehensive magnetic resonance imaging (MRI)-compatible electrophysiological (EP) acquisition system, which can acquire various physiological electrical signals, including electrocardiography (ECG), electromyography (EMG), electroencephalography (EEG) and electrocorticogram (ECoG), and EP recording combined with multimodal stimulation. The system is designed to be compatible with the 7-Tesla (7T) ultra-high field MRI environment, providing convenience for neuroscience and physiological research. To achieve MRI compatibility, the device uses magnetically compatible materials and shielding measures on the hardware and algorithm processing on the software side. Different filtering algorithms are adopted for different signals to suppress all kinds of interference in the MRI environment. The system can allow input signals up to ±0.225 V and channels up to 256. The equipment has been tested and proven to be able to collect a variety of physiological electrical signals effectively. When scanned under the condition of a 7T high-intensity magnetic field, the system does not generate obvious heating and can meet the safety requirements of MRI and EEG acquisition requirements. Moreover, an algorithm is designed and improved to efficiently and automatically remove the gradient artifact (GA) noise generated by MRI, which is a thousand-fold gradient artifact. Overall, this work proposes a complete, portable, MRI-compatible system that can collect a variety of physiological electrical signals and integrate more efficient GA removal algorithms.

16 January 2026 in Brain Sciences
Verified
Journal Article
Open access
PDF file
LLLi Li
Li Li
JXJie Xia
Jie Xia
PAPaul Alexander
Paul Alexander
SZSha Zhao
Sha Zhao
XZXiaoying Zhang
Xiaoying Zhang
Shurong DongShurong Dong
Shurong Dong
Background/Objectives: Sleep stage classification is crucial for assessing sleep quality and diagnosing related disorders. Electroencephalography (EEG) is currently recognized as a primary method for sleep stage classification. High-performance automatic sleep staging methods based on EEG leverage the powerful contextual modeling capabilities of Transformer Encoder architectures. However, the global self-attention mechanism in Transformers incurs significant computational overhead, substantially hindering the training and inference efficiency of automatic sleep staging algorithms. Methods: To address these issues, we introduce an end-to-end framework for automatic sleep stage classification using single-channel EEG: SleepMFormer. At the algorithmic level, SleepMFormer adopts a task-driven simplification of the Transformer encoder to improve attention efficiency while preserving sequence modeling capability. At the training level, supervised contrastive learning is incorporated as an auxiliary strategy to enhance representation robustness. From an engineering perspective, these design choices enable efficient training and inference under resource-constrained settings. Results: When integrated with the SleePyCo backbone, the proposed framework achieves competitive performance on three widely used public datasets: Sleep-EDF, PhysioNet, and SHHS. Notably, SleepMFormer reduces training and inference time by up to 33% compared to conventional self-attention-based models. To further validate the generalizability of MaxFormer, we conduct additional experiments using DeepSleepNet and TinySleepNet as alternative feature extractors. Experimental results demonstrate that MaxFormer consistently maintains performance across different model architectures. Conclusions: Overall, SleepMFormer introduces an efficient and practical framework for automatic sleep staging, demonstrating strong potential for related clinical applications.