Fan Zhang

Dr. Fan Zhang

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
JXJie Xia
Jie Xia
FZFan Zhang
Fan Zhang
LZLuxi Zhang
Luxi Zhang
ZCZhen Cao
Zhen Cao
Shurong DongShurong Dong
Shurong Dong
GZGuodong Zhou
Guodong Zhou
Advancements in brain–machine interfaces and neurological treatments urgently require the development of improved brain electrodes applied for long-term implantation, where traditional and polymer options face challenges like size, tissue damage, and signal quality. Carbon nanotubes are emerging as a promising alternative, combining excellent electronic properties and biocompatibility, which ensure better neuron coupling and stable signal acquisition. In this study, a new flexible brain electrode array based on 99.99% purity of single-walled carbon nanotubes (SWCNTs) was developed, which has 30 um × 40 um size, about 5.1 kΩ impedance, and 14.01 dB signal-to-noise ratio (SNR). The long-term implantation experiment in vivo in mice shows the proposed brain electrode can maintain stable LFP signal acquisition over 12 weeks while still achieving an SNR of 3.52 dB. The histological analysis results show that SWCNT-based brain electrodes induced minimal tissue damage and showed significantly reduced glial cell responses compared to platinum wire electrodes. Long-term stability comes from SWCNT’s biocompatibility and chemical inertness, the electrode’s flexible and fine structure. Furthermore, the new brain electrode array can function effectively during 7-Tesla magnetic resonance imaging, enabling the collection of local field potential and even epileptic discharges during the magnetic scan. This study provides a comprehensive study of carbon nanotubes as invasive brain electrodes, providing a new path to address the challenge of long-term brain electrode implantation.

29 August 2023 in Electronics
Verified
Journal Article
Open access
PDF file
JPjiadong pan
jiadong pan
JXJie Xia
Jie Xia
FZFan Zhang
Fan Zhang
LZLuxi Zhang
Luxi Zhang
Sameul ZhangSameul Zhang
Sameul Zhang
Shurong DongShurong Dong
Shurong Dong
This paper developed a comprehensive magnetic resonance imaging (MRI)-compatible electrophysiological (EP) acquisition system, which can acquire various physiological electrical signals, including electrocardiography (ECG), electromyography (EMG), electroencephalography (EEG) and electrocorticogram (ECoG), and EP recording combined with multimodal stimulation. The system is designed to be compatible with the 7-Tesla (7T) ultra-high field MRI environment, providing convenience for neuroscience and physiological research. To achieve MRI compatibility, the device uses magnetically compatible materials and shielding measures on the hardware and algorithm processing on the software side. Different filtering algorithms are adopted for different signals to suppress all kinds of interference in the MRI environment. The system can allow input signals up to ±0.225 V and channels up to 256. The equipment has been tested and proven to be able to collect a variety of physiological electrical signals effectively. When scanned under the condition of a 7T high-intensity magnetic field, the system does not generate obvious heating and can meet the safety requirements of MRI and EEG acquisition requirements. Moreover, an algorithm is designed and improved to efficiently and automatically remove the gradient artifact (GA) noise generated by MRI, which is a thousand-fold gradient artifact. Overall, this work proposes a complete, portable, MRI-compatible system that can collect a variety of physiological electrical signals and integrate more efficient GA removal algorithms.