Varvara Drizhd

Ms. Varvara Drizhd

L. M. Litvinenko Institute of Physical-Organic Chemistry and Coal Chemistry, Kyiv, Kyyiv, Misto, Ukraine
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2024 in Heliyon
Verified
Journal Article
Open access
Liubov VakhitovaLiubov Vakhitova
Liubov Vakhitova
KKKostyantyn Kalafat
Kostyantyn Kalafat
RVRamil Vakhitov
Ramil Vakhitov
VDVarvara Drizhd
Varvara Drizhd
The main aim of this study was to determine key factors that regulate fire-retardant effectiveness of intumescent coatings comprising of ammonium polyphosphate, melamine, pentaerythritol, polymer binder. Fulfillment of the research objectives resulted in the development of a coating with R120 fire resistance. The expected service life of the coating is at least 15 years when applied at Z2 type of environmental conditions (indoor use). It was established that in order to provide fire resistance of around R30 it is advisable to use the styrene-acrylic polymers as binders for both water-based and organic-based intumescent systems. The ratio of target components ammonium polyphosphate/melamine/pentaerythritol in such systems should be close to 2/1/1. The coating thickness is to be 0.4-0.5 mm. To achieve higher fire resistance (R60 or more) the coating should include a vinyl acetate derivative as a binder (copolymers with ethylene or vinylversatate). Target components ratio in this case is to be close to 3.5/1/1.5, while the coating thickness should be kept at 1.6-1.8 mm. If the required class of fire resistance is above R120, coating thickness is usually to be kept above 3.5 mm. In order to achieve higher fire resistance, it is advisable to use nano-clay additives and reinforcing fibers in intumescent compositions. The obtained results were used in the development of intumescent coating, which is produced industrially and provides over R120 fire resistance of steel, which was confirmed in standardized full-scale fire tests.

31 July 2023 in Chemical Engineering Journal Advances
Verified
Journal Article
Open access
Liubov VakhitovaLiubov Vakhitova
Liubov Vakhitova
KKKostyantyn Kalafat
Kostyantyn Kalafat
RVRamil Vakhitov
Ramil Vakhitov
VDVarvara Drizhd
Varvara Drizhd
NTNadiia Taran
Nadiia Taran
VBVolodymyr Bessarabov
Volodymyr Bessarabov

30 June 2020 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
SNSerhii Novak
Serhii Novak
VDVarvara Drizhd
Varvara Drizhd
ODOleksandr Dobrostan
Oleksandr Dobrostan
Thermal state of steel structures with a combined fire protection system under conditions of fire exposure

18 April 2019 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
SNSerhii Novak
Serhii Novak
VDVarvara Drizhd
Varvara Drizhd
ODOleksandr Dobrostan
Oleksandr Dobrostan
LMLarisa Maladyka
Larisa Maladyka
Influence of testing samples' parameters on the results of evaluating the fire­protective capability of materials

29 August 2025 in Technology audit and production reserves
Verified
Journal Article
Open access
PDF file
Liubov VakhitovaLiubov Vakhitova
Liubov Vakhitova
VDVarvara Drizhd
Varvara Drizhd
KKKostyantyn Kalafat
Kostyantyn Kalafat
Liubov VakhitovaLiubov Vakhitova
Liubov Vakhitova
NTNadiia Taran
Nadiia Taran
VBVolodymyr Bessarabov
Volodymyr Bessarabov
Fire protection of steel load-bearing building structures by surface-treating them with reactive fire-retardant coating materials is a crucial factor in ensuring fire safety on national scale. Both, the quality and operational characteristics of such materials, which are the subject of this study, require continuous improvement to reduce the cost of fire protection, as it can constitute a large portion of the overall construction expenditure. The aim of this study was to determine optimal rheological parameters for commercial reactive fire-retardant coating materials that ensure that the material can be applied with the maximum wet coating thickness. To achieve this aim, the dynamic viscosity (η) was measured using Brookfield viscometer for a set of commercial reactive fire-retardant coating materials that provide fire resistance of at least R120 for steel load-bearing structures. The dependence of viscosity on shear rate (γ) in the range of (2.09–52.25) s–1 was modeled using the Casson equation. This allowed for the determination of the main rheological parameters of the studied materials – shear stress (τ, Pa), yield stress (τ0, Pa), and viscosity at high shear rates (η∞, Pa · s), which contribute to material’s applicability. With the use of the empirical and calculational data, the approximate viscosity of water-based intumescent coating materials necessary to produce defect-free layer of wet coating on studied surfaces was determined. It was measured by Brookfield viscometer with No. 7 spindle at rotational speeds (30–50) rpm at 20°С, and should preferably be: (30–15) Pa · s, (at 1 mm wet coating thickness); (50–25) Pa · s, (at 1.5 mm wet coating thickness), (80–50) Pa · s, (at 2.0 mm wet coating thickness). These levels of viscosity prevent sedimentation and sagging of the coating during material’s application and can serve as reference markers for optimization of industrially manufactured intumescent fire-retardant products. The obtained results can serve as practical recommendations for manufacturers seeking to improve the rheology of reactive fire-retardant materials in order to increase the wet coating thickness per layer.

1 December 2020 in Scientific bulletin: Сivil protection and fire safety
Verified
Journal Article
Closed access
PDF file
ODO Dobrostan
O Dobrostan
SNS Novak
S Novak
VDVarvara Drizhd
Varvara Drizhd
The results of research of fire resistance of steel air ducts with the combined system of fire protection in the conditions of fire influence according to the standard temperature regime according to DSTU B V.1.1-4 are resulted. Steel air ducts were investigated, in the design of which two fire protection systems were used, in which passive fire protection material material (fiberglass "IPS-T-1000") and reactive fire protection material materials ("Endotherm HT-150" and "Endotherm 250103") were used. The research method is applied, which is based on the provisions of DSTU B V.1.1-16. The essence of this technique is that the samples of steel ducts are installed in the vertical support structure of the furnace and exposed to fire. According to the obtained experimental data, the integrity and thermal insulation capacity of air ducts are evaluated. According to the results of the research, the peculiarities of temperature distribution on the unheated surface of air ducts in the conditions of fire influence and characteristics of fire resistance of steel air ducts with the combined fire protection system are determined. It is shown that the temperature is most important on the unheated surface of the duct near the place of its compaction in the vertical enclosingstructure. The temperature on the surface of the duct at a distance of 325 mm from the enclosing structure is several tens of degrees lower than the temperature on the surface of the duct at a distance of 25 mm from it. The period of time to achieve the loss of thermal insulation capacity of air ducts and the class of their fire resistance, which is EI 45. The direction of further researches which are focused on revealing of dependencesbetween a time interval before achievement of loss of thermal insulation capacity and thickness of layers of the combined system of fire protection for steel air ducts is defined. This detection will determine the optimalparameters of the combined fire protection system for steel air ducts, acceptable to ensure their fire resistance for a wide range of duration of fire exposure at a standard temperature.