Seyed Morteza Moghimi

Mr. Seyed Morteza Moghimi

ECE, University of Victoria, Victoria, British Columbia, Canada
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2024 in Energies
Verified
Journal Article
Open access
PDF file
SMSeyed Morteza Moghimi
Seyed Morteza Moghimi
Thomas Aaron GulliverThomas Aaron Gulliver
Thomas Aaron Gulliver
TIT. Ilamparithi
T. Ilamparithi
Increasing building energy consumption has led to environmental and economic issues. Energy demand prediction (DP) aims to reduce energy use. Machine learning (ML) methods have been used to improve building energy consumption, but not all have performed well in terms of accuracy and efficiency. In this paper, these methods are examined and evaluated for modern building (MB) DP.

9 December 2024 in Energies
Verified
Journal Article
Open access
PDF file
SMSeyed Morteza Moghimi
Seyed Morteza Moghimi
Thomas Aaron GulliverThomas Aaron Gulliver
Thomas Aaron Gulliver
TIT. Ilamparithi
T. Ilamparithi
HTHossen Teimoornia
Hossen Teimoornia
This paper examines Connected Smart Green Townhouses (CSGTs) as a modern residential building model in Burnaby, British Columbia (BC). This model incorporates a wide range of sustainable materials and smart components such as recycled insulation, Photovoltaic (PV) solar panels, smart meters, and high-efficiency systems. The CSGTs operate in grid-connected mode to balance on-site renewables with grid resources to improve efficiency, cost-effectiveness, and sustainability. Real datasets are used to optimize resource consumption, including electricity, gas, and water. Renewable Energy Sources (RESs), such as PV systems, are integrated with smart grid technology. This creates an effective framework for managing energy consumption. The accuracy, efficiency, emissions, and cost are metrics used to evaluate CSGT performance. CSGTs with one to four bedrooms are investigated considering water systems and party walls. A deep Machine Learning (ML) model combining Long Short-Term Memory (LSTM) and a Convolutional Neural Network (CNN) is proposed to improve the performance. In particular, the Mean Absolute Percentage Error (MAPE) is below 5%, the Root Mean Square Error (RMSE) and Mean Absolute Error (MAE) are within acceptable levels, and R2 is consistently above 0.85. The proposed model outperforms other models such as Linear Regression (LR), CNN, LSTM, Random Forest (RF), and Gradient Boosting (GB) for all bedroom configurations.

10 January 2016 in Physical Science International Journal
Verified
Journal Article
Open access
PDF file
SMSeyed Morteza Moghimi
Seyed Morteza Moghimi
SSSeyed Mohammad Shariatmadar
Seyed Mohammad Shariatmadar
RDReza Dashti
Reza Dashti
Aims: Create a control policy for improve the quality of optimal voltage - frequency (V-F) power supply and stability analysis in a micro-grid scenario include DG units. Study Design: Control policy for respond to sudden changes such as starting micro-grid mode, and or in load change conditions was designed. Place and Duration of Study: IAU, Iran, February 2015-January 2016. Methodology: This paper with using of particle swarm optimization (PSO), model information analysis, and voltage and frequency stability of a micro-grid is controlled. Proposed controller of model include an inner current control loop and an outer power control loop based on synchronous reference frame and conventional PI regulators. Results: Simulation results show satisfactory performance voltage and frequency of system. Also, results show that proposed control policies established by acceptable limits voltage and frequency of system, and support from output power per some of DG unit in duration of load changes. In addition, simulation results improved system stability under proposed power controller and reduce errors in the proposed controller. The proposed PSO algorithm has good performance for finding the desired optimal control parameters to achieve the control objectives. Thus, automated enforcement mechanism based on the model information has been developed to determine these limits. Conclusion: The paper is presented a power (V-F) control policy for micro-grid based on PSO algorithm. This is done by proposed voltage and frequency controller based on PSO algorithm for real-time self-tuning. Besides, fast dynamic response and an acceptable level of harmonic distortion as two main basic system performance parameters were obtained. The main objectives are supplied power quality improvement and power stability, otherwise in faced to sudden changes such as transition from connection to grid mode to island mode or load change is located.

23 December 2024 in Energies
Verified
Journal Article
Open access
PDF file
SMSeyed Morteza Moghimi
Seyed Morteza Moghimi
Thomas Aaron GulliverThomas Aaron Gulliver
Thomas Aaron Gulliver
TIT. Ilamparithi
T. Ilamparithi
HTHossen Teimoornia
Hossen Teimoornia
This paper examines Connected Smart Green Buildings (CSGBs) in Burnaby, BC, Canada, with a focus on townhouses with one to four bedrooms. The proposed model integrates sustainable materials and smart components such as recycled insulation, Photovoltaic (PV) solar panels, smart meters, and high-efficiency systems. These elements improve energy efficiency and promote sustainability. Operating in island mode, CSGBs can function independently of the grid, providing resilience during power outages and reducing reliance on external energy sources. Real data on electricity, gas, and water consumption are used to optimize load management under isolated conditions. Electric Vehicles (EVs) are also considered in the system. They serve as energy storage devices and, through Vehicle-to-Grid (V2G) technology, can supply power when needed. A hybrid Machine Learning (ML) model combining Long Short-Term Memory (LSTM) and a Convolutional Neural Network (CNN) is proposed to improve the performance. The metrics considered include accuracy, efficiency, emissions, and cost. The performance was compared with several well-known models including Linear Regression (LR), CNN, LSTM, Random Forest (RF), Gradient Boosting (GB), and hybrid LSTM–CNN, and the results show that the proposed model provides the best results. For a four-bedroom Connected Smart Green Townhouse (CSGT), the Mean Absolute Percentage Error (MAPE) is 4.43%, the Root Mean Square Error (RMSE) is 3.49 kWh, the Mean Absolute Error (MAE) is 3.06 kWh, and R2 is 0.81. These results indicate that the proposed model provides robust load optimization, particularly in island mode, and highlight the potential of CSGBs for sustainable urban living.

1 May 2018 in Indian Journal of Science and Technology
Verified
Journal Article
Open access
ABAli Bostani
Ali Bostani
SMSeyed Morteza Moghimi
Seyed Morteza Moghimi
RDReza Dashti
Reza Dashti
SHSeyed Mostafa Hashemi
Seyed Mostafa Hashemi
Objectives: The unwanted and unplanned outages due to faults occurred in electrical energy distribution systems are one of the main concerns of distribution companies. This paper examines this concerning. Methods/Statistical Analysis: This paper examines about ninety outages in related to the medium pressure power lines in second region of Bushehr over twomonth period. Findings: It has identified faults caused by power outages, and the time of outage for each fault is extracted in all regions of the primary data obtained from the power events. Then, by determining the cost function with the purely economic factors, are obtained the costs of each fault individually. In the following, for each fault are provided a series of preventive overhauls or preventive recommendations. Until increasing the system’s trustworthiness, the operating costs of unwanted faults are completely eliminated or minimized. Application/Improvements: The application of this paper is that examines the roles of preventive major maintenance in the costs of electric energy distribution companies.

10 January 2016 in Physical Science International Journal
Verified
Journal Article
Open access
PDF file
SMSeyed Morteza Moghimi
Seyed Morteza Moghimi
GSGholamreza Sarlak
Gholamreza Sarlak
Aims: The aim of the paper is to create two different models of integrated energy systems (HUBs) that improve combined approach of CHP temperature and net zero emission (NZE) effects. Study Design: The design model includes two energy HUBs with different characteristics in one hour and twenty-four hours. The cost function of these models are composed of two parts: Part one is related to generation cost and part two is related to emission cost. Place and Duration of Study: IAU, Iran, January 2015 - January 2016. Methodology: The model scenario is obtained through MINLP solver of GAMS software version 24.1.2, MATLAB software version 2013 and Excel software version 2010. Results: The simulation results have shown existence of NZE constraint can that use amounts of carriers that include pollution reduction then and in addition, with costs reduction caused by pollution reduction. Conclusion: This paper studies the optimization in energy HUB. Also, the paper has improved combined approach of temperature and emission effects for HUB. The cost function of paper models are composed of two parts; Generation cost and emission cost. The emission penalties caused by change of carriers and generation of toxic gas. Then, combined heat and power (CHP), NZE, ambient temperature equations and constraints on models equations have been investigated. In addition, the innovations of paper are pollution calculation and optimization of the entries in terms of output, weighted coefficient of pollution, adding temperature effect on CHP performance and it’s optimization with optimization in generation by minimizing pollution, adding NZE constraint and finding the optimum economic capacity for equipment purchase without paying to additional costs.