Diana Guimarães

Dr. Diana Guimarães

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2016 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
Diana GuimarãesDiana Guimarães
Diana Guimarães
MPMeredith L. Praamsma
Meredith L. Praamsma
PPPatrick J Parsons
Patrick J Parsons

21 December 2015 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
KMKathryn G. McIntosh
Kathryn G. McIntosh
Diana GuimarãesDiana Guimarães
Diana Guimarães
MCMatthew J. Cusack
Matthew J. Cusack
AVAlexei Vershinin
Alexei Vershinin
ZCZ.W. Chen
Z.W. Chen
PPPatrick J Parsons
Patrick J Parsons
Portable instruments based on X-Ray Fluorescence Spectrometry (XRF) have the potential to assist in field-based studies, provided that the data produced are reliable. In this study, we evaluate the performance of two different types of XRF instrument (XOS prototype and Thermo Niton XL3t). These two XRF analysers were evaluated in a laboratory setting, and data were reported for 17 elements (As, Ba, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se, Sn, Sr, Ti, V, and Zn). Samples analysed (n = 38) included ethnic herbal medicine products (HMPs), ethnic spices (ES), and cosmetic products (CPs). Comparison analyses were carried out using Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). In general, results reported for Cd, Cu, and Pb by the XOS prototype analyser, using the non-metal mode, were negatively biased (5–95%) as compared to ICP-OES. In contrast, results reported for Pb, As, Cd, Cu and Zn by the Niton, using the soil mode, were positively biased, in some instances (Cd) by up to four orders of magnitude. While the sensitivity of both instruments was insufficient for reliably ‘quantifying’ toxic elements below 15 mg/kg, XRF was still capable of positively ‘detecting’ many elements at the low single-digit mg/kg levels. For semi-quantification estimates of contaminants at higher levels, and with limited sample preparation, both XRF instruments were deemed fit for the purpose. This study demonstrates that modern XRF instrumentation is valuable for characterising the elemental content of food, cosmetic, and medicinal products. The technology is particularly useful for rapidly screening large numbers of products (100’s per day) in the field, and quickly identifying those that may contain potentially hazardous levels of toxic elements. Toxic elements can be confirmed by examining the raw spectrum, and the limitations of factory-based calibration are generally manageable for field-based studies.

22 October 2021 in Minerals
Verified
Journal Article
Open access
PDF file
Ricardo RibeiroRicardo Ribeiro
Ricardo Ribeiro
DCDiana Faria Capela
Diana Faria Capela
MFMiguel Ferreira
Miguel Ferreira
RMRui Martins
Rui Martins
Pedro JorgePedro Jorge
Pedro Jorge
ALALEXANDRE Lima
ALEXANDRE Lima
In this work, X-ray fluorescence (XRF) and Laser-induced breakdown spectroscopy (LIBS) analyses were applied to samples of quartz, montebrasite, and turquoise hydrothermal veins in the Argemela Tin Mine (Central Portugal). Montebrasite (LiAl(PO4)(OH,F)) is potentially the main ore mineral; with its alteration, lithium (Li) can disseminate into other minerals. A hand sample was cut and analyzed by XRF and LIBS for several elements of interest including Cu, P, Al, Si, and Li. Although XRF cannot measure Li, results from its analysis are effective for distinguishing turquoise from montebrasite. LIBS analysis complemented this study, making it possible to conclude that turquoise does not contain any significant Li in its structure. The difference in spot size between the techniques (5 mm vs. 300 µm for XRF and LIBS, respectively) resulted in a poorer performance by XRF in accurately identifying mixed minerals. A thin section was petrographically characterized and mapped using LIBS. The mapping results demonstrate the possibility of the successful identification of minerals and their alterations on a thin section. The results of XRF analysis and LIBS mapping in petrographic sections demonstrate the efficacy of these methods as tools for element and mineral identification, which can be important in exploration and mining phases, complementing more traditional techniques.

1 February 2017 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
DFDavid Fleming
David Fleming
MNMichel N. Nader
Michel N. Nader
KFKelly A. Foran
Kelly A. Foran
CGCraig Groskopf
Craig Groskopf
MRMichael C. Reno
Michael C. Reno
PPPatrick J. Parsons
Patrick J. Parsons

1 October 2012 in Journal of Trace Elements in Medicine and Biology
Verified
Journal Article
Closed access
Diana GuimarãesDiana Guimarães
Diana Guimarães
MCMaria Leonor Carvalho
Maria Leonor Carvalho
VGVera Lúcia Poço Geraldes
Vera Lúcia Poço Geraldes
IRIsabel Rocha
Isabel Rocha
LALuis Alves
Luis Alves
Jose SantosJose Santos
Jose Santos

1 August 2018 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
Diana GuimarãesDiana Guimarães
Diana Guimarães
ARAustin A. Roberts
Austin A. Roberts
MTMina W. Tehrani
Mina W. Tehrani
RHRong Huang
Rong Huang
LSLouisa Smieska
Louisa Smieska
PPPatrick J Parsons
Patrick J Parsons
The arsenic content of dried baby shrimp (Acetes sp.) was investigated as part of an independent field study of human exposure to toxic metals/metalloids among the ethnic Chinese community located in Upstate New York. The dried baby shrimp were analyzed in a home environment using a portable X-Ray Fluorescence (XRF) instrument based on monochromatic excitation. Study participants had obtained their dried baby shrimp either from a local Chinese market or prepared them at home. The shrimp are typically between 10–20 mm in size and are consumed whole, without separating the tail from the head. Elevated levels of As were detected using portable XRF, ranging between 5–30 μg g−1. Shrimp samples were taken to the Cornell High Energy Synchrotron Source (CHESS) for Synchrotron Radiation μXRF (SR-μXRF) elemental mapping using a 384-pixel Maia detector system. The Maia detector provided high resolution trace element images for As, Ca, and Br, (among others) and showed localized accumulation of As within the shrimp's cephalothorax (head), and various abdominal segments. As quantification by SR-μXRF was performed using a lobster hepatopancreas reference material pellet (NRC-CNRC TORT-2), with results in good agreement with both portable XRF and ICP-MS. Additional As characterization using μX-ray Absorption Near Edge Spectroscopy (μXANES) with the Maia XRF detector at CHESS identified arsenobetaine and/or arsenocholine as the possible As species present. Further arsenic speciation analysis by LC-ICP-MS/MS confirmed that the majority of As (>95%) is present as the largely non-toxic arsenobetaine species with trace amounts of arsenocholine, methylated As and inorganic As species detected.