Grid-connected power-converter-interfaced systems have been sharing the responsibility of grid generation alongside conventional synchronous generators. However, these systems lack spinning reserves, leading to a decrease in system inertia and resulting in more pronounced frequency deviations during power imbalances. Therefore, grid codes require the active involvement of wind energy conversion systems in frequency control, aiming to constrain the frequency and rate of change of frequency variations within predefined limits. This paper reviews fast power-reserve control techniques without energy storage in wind energy conversion systems that do not depend on frequency or rate of change of frequency values. The resulting effects on system frequency, energy production, mechanical loadings, and electrical loadings are assessed. The techniques are classified in the maximum-power point-tracking region according to the power function during the transient response, such as constant, speed-, time-, or mechanical power-dependent methods. Both overproduction and underproduction stages are considered. Certain techniques are tested on simulation grids that include either hydro or no-reheat steam generators, followed by a comparative analysis.
23 August 2023 in IEEE Open Journal of Industry Applications
The integration of offshore wind energy power system is a solution to reduce carbon emissions in the oil and gas sector. However, the intermittent profile of wind power generation can bring challenges of voltage/frequency fluctuations to the electrical grid of the platform. This paper proposes a coordinated decentralized control used to mitigate voltage fluctuation in oil and gas platform caused by connection of wind power system through short- and long- umbilical cables. The proposed control is split into optimum loss control embedded in the wind power system control, and modified dynamic volt-var functions applied to active front-end variable frequency drives. The decentralized control is evaluated by means of simulation results considering a real case test bench of a typical Brazilian offshore platform with a wind power system of 10 MW and 50 MW, and umbilical cable of 12 km and 150 km. The results indicate an effective contribution of the dynamic volt-var function in reducing voltage fluctuations for the three implemented wind power system configurations (i.e., 10 MW/12 km; 50 MW/12 km and 50 MW/150 km).
Power-converter-based energy-harvesting and storage systems are becoming more prevalent in the electrical grid, replacing conventional synchronous generators. Consequently, grid inertia is diminishing, and to address this, inverter-based energy conversion systems are required by grid codes to provide frequency control support to the main grid. This is undertaken to increase the equivalent inertia of the system and reduce frequency variations. This type of control is necessary and designed for handling large system transients. However, it also impacts the small-signal stability of the grid-connected converters. To investigate this issue, this paper addresses the influence of synthetic inertia control on the output admittance of a grid-following inverter and its interaction with the grid equivalent impedance. A synchronous reference frame dynamic model of the grid-following inverter closed-loop system is obtained and linearized at an operating point to analyze the small-signal stability of the low-switching frequency inverter. The models are validated through numerical simulations. The analysis verifies the interactions of the internal control loops, such as the AC current control with voltage feedforward, DC-link voltage control with power-feedforward, phase-locked loop, and AC voltage control with inertial control. Additionally, the interactions between the output admittance of the inverter and the grid impedance are verified using the generalized Nyquist criterion. The stability regions are validated through simulations, and the results show that the system gain margin is reduced for increasing values of synthetic inertia gain and lower grid short-circuit ratios. Furthermore, there is a limit in the voltage and power-feedforward bandwidth to avoid degrading the system stability when utilizing the synthetic inertia control.
2 June 2025 in International Journal of Dynamics and Control
Offshore wind energy conversion systems have an inherent control challenge due to the long transmission cables necessary to deliver the generated power to an energy station. Grid-tied power system with a transmission cable has dynamics that threaten system stability. In this sense, controlling this kind of system subject to exogenous disturbances is not trivial, requiring sophisticated control algorithms whose parameter tuning is not intuitive. Therefore, this work presents a robust adaptive current control approach optimized with a new improved chaotic stochastic fractal search algorithm with fitness-distance balance (SFS-FDB). This novel optimizer uses a stochastic selective strategy of ten chaotic maps to improve the SFS-FDB performance. The modification consists in replacing the random variables in the SFS-FDB algorithm with values generated by chaotic maps, independently, at each iteration, enhancing the diversity in the solution, which avoids premature convergence, stagnation, and biased solutions. Four scenarios are considered to evaluate the resulting optimized controller: current reference changes, two grid inductance variations (including up to ten times the nominal value of grid-side inductance), and grid frequency oscillations. Simulation results demonstrate the effectiveness of the developed intelligent control solution, making the tracking errors converge to residual values in steady state when the renewable energy system operates under weak grid conditions.