Kassiane de S. Medeiros

Kassiane de S. Medeiros

Auto-generated profile, based on publicly available information

Kassiane de S. Medeiros

Universidade Federal de Minas Gerais

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2023 in IEEE Open Journal of Industry Applications
Verified
Journal Article
Open access
LRLorrana F. da Rocha
Lorrana F. da Rocha
Danilo BrandaoDanilo Brandao
Danilo Brandao
KMKassiane de S. Medeiros
Kassiane de S. Medeiros
MDMatheus Schramm Dall'Asta
Matheus Schramm Dall'Asta
Telles Brunelli LazzarinTelles Brunelli Lazzarin
Telles Brunelli Lazzarin
The integration of offshore wind energy power system is a solution to reduce carbon emissions in the oil and gas sector. However, the intermittent profile of wind power generation can bring challenges of voltage/frequency fluctuations to the electrical grid of the platform. This paper proposes a coordinated decentralized control used to mitigate voltage fluctuation in oil and gas platform caused by connection of wind power system through short- and long- umbilical cables. The proposed control is split into optimum loss control embedded in the wind power system control, and modified dynamic volt-var functions applied to active front-end variable frequency drives. The decentralized control is evaluated by means of simulation results considering a real case test bench of a typical Brazilian offshore platform with a wind power system of 10 MW and 50 MW, and umbilical cable of 12 km and 150 km. The results indicate an effective contribution of the dynamic volt-var function in reducing voltage fluctuations for the three implemented wind power system configurations (i.e., 10 MW/12 km; 50 MW/12 km and 50 MW/150 km).

7 March 2025 in Eletrônica de Potência
Verified
Journal Article
Open access
PDF file
KMKassiane de S. Medeiros
Kassiane de S. Medeiros
JCJoão Marcus Soares Callegari
João Marcus Soares Callegari
AAAyotunde Adekunle Adeyemo
Ayotunde Adekunle Adeyemo
Elisabetta TedeschiElisabetta Tedeschi
Elisabetta Tedeschi
Danilo BrandaoDanilo Brandao
Danilo Brandao
This paper aims to analyze the effect of high penetration of floating offshore wind-based power generation on the power quality of a Floating Production Storage and Offloading (FPSO) power system. The paper focuses on the continuous frequency variation caused by intermittent wind power generation and an energy storage-based solution for power smoothing. A set of results simulated in MATLAB/Simulink® is shown to assess different operational scenarios of a typical Brazilian FPSO from the Mero Oil Field, powered by 109 MVA/ 87 MW from three synchronous generators, without wind power. Wind power penetration varies from 10 to 50 MW, and the effects of this variation on FPSO power quality are reported. Then, the number of gas turbine generators is reduced from 3 to 2 generators. Finally, the energy storage for power smoothing purposes is evaluated. Conclusions are drawn based on steady-state and transient voltage and frequency profiles, active and reactive power flow between loads and generation, the rate of change of frequency, and frequency nadir.

12 November 2024 in Eletrônica de Potência
Verified
Journal Article
Open access
PDF file
KMKassiane de S. Medeiros
Kassiane de S. Medeiros
JCJoão Marcus Soares Callegari
João Marcus Soares Callegari
LRLorrana F. Da Rocha
Lorrana F. Da Rocha
Danilo BrandaoDanilo Brandao
Danilo Brandao
Renewable energy resources emerge as a sustainable alternative to augmenting the energy supply of floating production storage and offloading (FPSO) platforms. However, the increased generation at FPSO based on converter-interfaced energy decreases the system-equivalent inertia constant, which becomes more susceptible to frequency deviations. This paper proposes and evaluates the combined frequency-voltage-var control performance to mitigate frequency variation in a typical FPSO unit with penetration of floating wind energy generation. The control functions are communication-free and embedded in the active front-end variable frequency drives (AFE-VFDs), which are installed on the FPSO and have the primary function of controlling the speed of water injection pumps. The FPSO electrical power system model is developed in MATLAB/Simulink®. Comparative results obtained from the AFE-VFD equipped with volt-var, freq-var, and combined freq-volt-var functions are shown to highlight the proposed solution merits. The results have shown a conflicting behavior with the frequency and voltage deviation improvement associated with absorption and injection of reactive power, respectively. Accordingly, the frequency-volt-var prioritizes frequency deviations during heavy transient events and voltage deviations during regular operation.