Robin Mieling

Mr. Robin Mieling

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
FBFinn Behrendt
Finn Behrendt
DBDebayan Bhattacharya
Debayan Bhattacharya
RMRobin Mieling
Robin Mieling
LMLennart Maack
Lennart Maack
JKJulia Krüger
Julia Krüger
ASAlexander Schlaefer
Alexander Schlaefer
The application of supervised models to clinical screening tasks is challenging due to the need for annotated data for each considered pathology. Unsupervised Anomaly Detection (UAD) is an alternative approach that aims to identify any anomaly as an outlier from a healthy training distribution. A prevalent strategy for UAD in brain MRI involves using generative models to learn the reconstruction of healthy brain anatomy for a given input image. As these models should fail to reconstruct unhealthy structures, the reconstruction errors indicate anomalies. However, a significant challenge is to balance the accurate reconstruction of healthy anatomy and the undesired replication of abnormal structures. While diffusion models have shown promising results with detailed and accurate reconstructions, they face challenges in preserving intensity characteristics, resulting in false positives. We propose conditioning the denoising process of diffusion models with additional information derived from a latent representation of the input image. We demonstrate that this conditioning allows for accurate and local adaptation to the general input intensity distribution while avoiding the replication of unhealthy structures. We compare the novel approach to different state-of-the-art methods and for different data sets. Our results show substantial improvements in the segmentation performance, with the Dice score improved by 11.9%, 20.0%, and 44.6%, for the BraTS, ATLAS and MSLUB data sets, respectively, while maintaining competitive performance on the WMH data set. Furthermore, our results indicate effective domain adaptation across different MRI acquisitions and simulated contrasts, an important attribute for general anomaly detection methods. The code for our work is available at https://github.com/FinnBehrendt/Conditioned-Diffusion-Models-UAD.

10 January 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MNMaximilian Neidhardt
Maximilian Neidhardt
RMRobin Mieling
Robin Mieling
MBMarcel Bengs
Marcel Bengs
ASAlexander Schlaefer
Alexander Schlaefer
Robotic assistance in minimally invasive surgery offers numerous advantages for both patient and surgeon. However, the lack of force feedback in robotic surgery is a major limitation, and accurately estimating tool-tissue interaction forces remains a challenge. Image-based force estimation offers a promising solution without the need to integrate sensors into surgical tools. In this indirect approach, interaction forces are derived from the observed deformation, with learning-based methods improving accuracy and real-time capability. However, the relationship between deformation and force is determined by the stiffness of the tissue. Consequently, both deformation and local tissue properties must be observed for an approach applicable to heterogeneous tissue. In this work, we use optical coherence tomography, which can combine the detection of tissue deformation with shear wave elastography in a single modality. We present a multi-input deep learning network for processing of local elasticity estimates and volumetric image data. Our results demonstrate that accounting for elastic properties is critical for accurate image-based force estimation across different tissue types and properties. Joint processing of local elasticity information yields the best performance throughout our phantom study. Furthermore, we test our approach on soft tissue samples that were not present during training and show that generalization to other tissue properties is possible.

26 January 2022 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Open access
MNMaximilian Neidhardt
Maximilian Neidhardt
SGStefan Gerlach
Stefan Gerlach
RMRobin Mieling
Robin Mieling
MLMax-Heinrich Laves
Max-Heinrich Laves
TWThorben Weiß
Thorben Weiß
ASAlexander Schlaefer
Alexander Schlaefer
In pathology and legal medicine, the histopathological and microbiological analysis of tissue samples from infected deceased is a valuable information for developing treatment strategies during a pandemic such as COVID-19. However, a conventional autopsy carries the risk of disease transmission and may be rejected by relatives. We propose minimally invasive biopsy with robot assistance under CT guidance to minimize the risk of disease transmission during tissue sampling and to improve accuracy. A flexible robotic system for biopsy sampling is presented, which is applied to human corpses placed inside protective body bags. An automatic planning and decision system estimates optimal insertion point. Heat maps projected onto the segmented skin visualize the distance and angle of insertions and estimate the minimum cost of a puncture while avoiding bone collisions. Further, we test multiple insertion paths concerning feasibility and collisions. A custom end effector is designed for inserting needles and extracting tissue samples under robotic guidance. Our robotic post-mortem biopsy (RPMB) system is evaluated in a study during the COVID-19 pandemic on 20 corpses and 10 tissue targets, 5 of them being infected with SARS-CoV-2. The mean planning time including robot path planning is 5.72±167s. Mean needle placement accuracy is 7.19± 422mm.

3 October 2024
Verified
Book Chapter
Closed access
PDF file
FBFinn Behrendt
Finn Behrendt
DBDebayan Bhattacharya
Debayan Bhattacharya
RMRobin Mieling
Robin Mieling
LMLennart Maack
Lennart Maack
JKJulia Krüger
Julia Krüger
ASAlexander Schlaefer
Alexander Schlaefer

11 May 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SLSarah Latus
Sarah Latus
SGSarah Grube
Sarah Grube
TETim Eixmann
Tim Eixmann
MNMaximilian Neidhardt
Maximilian Neidhardt
SGStefan Gerlach
Stefan Gerlach
ASAlexander Schlaefer
Alexander Schlaefer
Objective: Optical coherence elastography (OCE) allows for high resolution analysis of elastic tissue properties. However, due to the limited penetration of light into tissue, miniature probes are required to reach structures inside the body, e.g., vessel walls. Shear wave elastography relates shear wave velocities to quantitative estimates of elasticity. Generally, this is achieved by measuring the runtime of waves between two or multiple points. For miniature probes, optical fibers have been integrated and the runtime between the point of excitation and a single measurement point has been considered. This approach requires precise temporal synchronization and spatial calibration between excitation and imaging. Methods: We present a miniaturized dual-fiber OCE probe of $1 \,\mathrm{m}\mathrm{m}$ diameter allowing for robust shear wave elastography. Shear wave velocity is estimated between two optics and hence independent of wave propagation between excitation and imaging. We quantify the wave propagation by evaluating either a single or two measurement points. Particularly, we compare both approaches to ultrasound elastography. Results: Our experimental results demonstrate that quantification of local tissue elasticities is feasible. For homogeneous soft tissue phantoms, we obtain mean deviations of $0.15 \,\mathrm{m}\mathrm{s}^{-1}$ and $0.02 \,\mathrm{m}\mathrm{s}^{-1}$ for single-fiber and dual-fiber OCE, respectively. In inhomogeneous phantoms, we measure mean deviations of up to $0.54 \,\mathrm{m}\mathrm{s}^{-1}$ and $0.03 \,\mathrm{m}\mathrm{s}^{-1}$ for single-fiber and dual-fiber OCE, respectively. Conclusion: We present a dual-fiber OCE approach that is much more robust in inhomogeneous tissues. Moreover, we demonstrate the feasibility of elasticity quantification in ex-vivo coronary arteries. Significance: This study introduces an approach for robust elasticity quantification from within the tissue.

20 May 2022
Verified
Book Chapter
Open access
PDF file
RMRobin Mieling
Robin Mieling
CSCarolin Stapper
Carolin Stapper
SGStefan Gerlach
Stefan Gerlach
MNMaximilian Neidhardt
Maximilian Neidhardt
SLSarah Latus
Sarah Latus
ASAlexander Schlaefer
Alexander Schlaefer
Collaborative robotic needle insertions have the potential to improve placement accuracy and safety, e.g., during epidural anesthesia. Epidural anesthesia provides effective regional pain management but can lead to serious complications, such as nerve injury or cerebrospinal fluid leakage. Robotic assistance might prevent inadvertent puncture by providing haptic feedback to the physician. Haptic feedback can be realized on the basis of force measurements at the needle. However, contact should be avoided for delicate structures. We propose a proximity-based method to provide feedback prior to contact. We measure the distance to boundary layers, visualize the proximity for the operator and further feedback it as a haptic resistance. We compare our approach to haptic feedback based on needle forces and visual feedback without haptics. Participants are asked to realize needle insertions with each of the three feedback modes. We use phantoms that mimic the structures punctured during epidural anesthesia. We show that visual feedback improves needle placement, but only proximity-based haptic feedback reduces accidental puncture. The puncture rate is 62% for force-based haptic feedback, 60% for visual feedback and 6% for proximity-based haptic feedback. Final needle placement inside the epidural space is achieved in 38%, 70% and 96% for force-based haptic, visual and proximity-based haptic feedback, respectively. Our results suggest that proximity-based haptic feedback could improve needle placement safety in the context of epidural anesthesia.