Tim Eixmann

Tim Eixmann

Auto-generated profile, based on publicly available information

Tim Eixmann

Medical Laser Center Lübeck GmbH, Lübeck, Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2019 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
SJSonja Jäckle
Sonja Jäckle
TETim Eixmann
Tim Eixmann
HSHinnerk Schulz-Hildebrandt
Hinnerk Schulz-Hildebrandt
GHGereon Hüttmann
Gereon Hüttmann
TPTorben Pätz
Torben Pätz
Purpose Endovascular aortic repair procedures are currently conducted with 2D fluoroscopy imaging. Tracking systems based on fiber Bragg gratings are an emerging technology for the navigation of minimally invasive instruments which can reduce the X-ray exposure and the used contrast agent. Shape sensing of flexible structures is challenging and includes many calculations steps which are prone to different errors. To reduce this errors, we present an optimized shape sensing model. Methods We analyzed for every step of the shape sensing process, which errors can occur, how the error affects the shape and how it can be compensated or minimized. Experiments were done with one multicore fiber system with 38 cm sensing length, and the effects of different methods and parameters were analyzed. Furthermore, we compared 3D shape reconstructions with the segmented shape of the corresponding CT scans of the fiber to evaluate the accuracy of our optimized shape sensing model. Finally, we tested our model in a realistic endovascular scenario by using a 3D printed vessel system created from patient data. Results Depending on the complexity of the shape, we reached an average error of 0.35–1.15 mm and maximal error of 0.75–7.53 mm over the whole 38 cm sensing length. In the endovascular scenario, we obtained an average and maximal error of 1.13 mm and 2.11 mm, respectively. Conclusion The accuracies of the 3D shape sensing model are promising, and we plan to combine the shape sensing based on fiber Bragg gratings with the position and orientation of an electromagnetic tracking to obtain the located catheter shape.

28 July 2018 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
MOM. Ourak
M. Ourak
JSJonas Victor Harmen Smits
Jonas Victor Harmen Smits
LEL. Esteveny
L. Esteveny
GBGianni Borghesan
Gianni Borghesan
AGA. Gijbels
A. Gijbels
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten

26 November 2021 in Ophthalmology Science
Verified
Journal Article
Open access
MCMatteo Giuseppe Cereda
Matteo Giuseppe Cereda
SPSalvatore Parrulli
Salvatore Parrulli
YDY.G.M. Douven
Y.G.M. Douven
KFKoorosh Faridpooya
Koorosh Faridpooya
SRSaskia van Romunde
Saskia van Romunde
MSMarc D. de Smet
Marc D. de Smet
To assess the efficacy of an instrument-integrated OCT (iiOCT)-based distance sensor during robotic vitreoretinal surgery using the Preceyes Surgical System (PSS; Preceyes B.V.). Single-center interventional study. Patients requiring vitreoretinal surgery. Five patients were enrolled. Standard preoperative OCT images were obtained. After vitrectomy, a predefined set of actions was performed using the iiOCT-based sensor. Images then were processed to assess the signal-to-noise ratio (SNR) at various angles to the retina and at different distances between the instrument tip and the retinal surface. Preoperative and intraoperative OCT images were compared qualitatively and quantitatively. The feasibility in performing surgical tasks using the iiOCT-based sensor during vitreoretinal surgery, the SNR when imaging the retina, differences among intraoperative and preoperative OCT images, and characteristics of intraoperative retinal movements detected with the iiOCT-based probe. Surgeons were able to perform all the tasks but one. The PSS was able to maintain a fixed distance. The SNR of the iiOCT-based sensor signal was adequate to determine the distance to the retina and to control the PSS. Analysis of iiOCT-based sensor A-scans identified 3 clearly distinguishable retinal layers, including the inner retinal boundary and the interface at the retinal pigment epithelium–Bruch’s membrane. Thickness values differed by less than 5% from that measured by preoperative OCT, indicating its accuracy. The Fourier analysis of iiOCT-based sensor recordings identified anteroposterior retinal movements attributed to heartbeat and respiration. This iiOCT-based sensor was tested successfully and promises reliable use during robot-assisted surgery. An iiOCT-based sensor is a promising step toward OCT-guided robotic retinal surgery.

7 September 2018 in Optics Letters
Verified
Journal Article
Closed access
PDF file
HSHinnerk Schulz-Hildebrandt
Hinnerk Schulz-Hildebrandt
TPTom Pfeiffer
Tom Pfeiffer
TETim Eixmann
Tim Eixmann
SLSabrina Lohmann
Sabrina Lohmann
MAMartin Ahrens
Martin Ahrens
GHGereon Hüttmann
Gereon Hüttmann
We present a forward-viewing fiber scanning endoscope (FSE) for high-speed volumetric optical coherence tomography (OCT). The reduction in size of the probe was achieved by substituting the focusing optics by an all-fiber-based imaging system which consists of a combination of scanning single-mode fibers, a glass spacer, made from a step-index multi-mode fiber, and a gradient-index fiber. A lateral resolution of 11 μm was achieved at a working distance of 1.2 mm. The newly designed piezo-based FSE has an outer diameter of 1.6 mm and a rigid length of 13.5 mm. By moving the whole imaging optic in spirals for scanning the sample, the beam quality remains constant over the entire field of view with a diameter of 0.8 mm. The scanning frequency was adjusted to 1.22 kHz for use with a 3.28 MHz Fourier domain mode locked OCT system. Densely sampled volumes have been imaged at a rate of 6 volumes per second.

7 May 2020 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
SJSonja Jäckle
Sonja Jäckle
VGVerónica García-Vázquez
Verónica García-Vázquez
TETim Eixmann
Tim Eixmann
FMFlorian Matysiak
Florian Matysiak
Felix von HaxthausenFelix von Haxthausen
Felix von Haxthausen
TPTorben Pätz
Torben Pätz
Purpose: During endovascular aneurysm repair (EVAR) procedures, medical instruments are guided with two-dimensional (2D) fluoroscopy and conventional digital subtraction angiography. However, this requires X-ray exposure and contrast agent is used, and the depth information is missing. To overcome these drawbacks, a three-dimensional (3D) guidance approach based on tracking systems is introduced and evaluated. Methods: A multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape were integrated into a stentgraft system. A model for obtaining the located shape of the first 38 cm of the stentgraft system with two EM sensors is introduced and compared with a method based on three EM sensors. Both methods were evaluated with a vessel phantom containing a 3D-printed vessel made of silicone and agar-agar simulating the surrounding tissue. Results: The evaluation of the guidance methods resulted in average errors from 1.35 to 2.43 mm and maximum errors from 3.04 to 6.30 mm using three EM sensors, and average errors from 1.57 to 2.64 mm and maximum errors from 2.79 to 6.27 mm using two EM sensors. Moreover, the videos made from the continuous measurements showed that a real-time guidance is possible with both approaches. Conclusion: The results showed that an accurate real-time guidance with two and three EM sensors is possible and that two EM sensors are already sufficient. Thus, the introduced 3D guidance method is promising to use it as navigation tool in EVAR procedures. Future work will focus on developing a method with less EM sensors and a detailed latency evaluation of the guidance method.

17 March 2020
Verified
Conference Paper
Closed access
PDF file
SJSonja Jäckle
Sonja Jäckle
VGVerónica García-Vázquez
Verónica García-Vázquez
Felix von HaxthausenFelix von Haxthausen
Felix von Haxthausen
TETim Eixmann
Tim Eixmann
MSMalte Maria Sieren
Malte Maria Sieren
TPTorben Paetz
Torben Paetz
Currently, uoroscopy and conventional digital subtraction angiography are used for imaging guidance in endovascular aortic repair (EVAR) procedures. Drawbacks of these image modalities are X-ray exposure, the usage of contrast agents and the lack of depth information. To overcome these disadvantages, a catheter prototype containing a multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape was built in this study. Furthermore, a model for processing the input data from the tracking systems to obtain the located 3D shape of the first 38 cm of the catheter was introduced: A spatial calibration between the optical fiber and each EM sensor was made in a calibration step and used to obtain the located shape of the catheter in subsequent experiments. The evaluation of our shape localization method with the catheter prototype in different shapes resulted in average errors from 0.99 to 2.29 mm and maximum errors from 1.73 to 2.99 mm. The experiments showed that an accurate shape localization with a multicore fiber and three EM sensors is possible, and that this catheter guidance is promising for EVAR procedures. Future work will be focused on the development of catheter guidance based on shape sensing with a multicore fiber, and the orientation and position of less than three EM sensors.