To study the effect of temperature on the seismic performance of a prestressed reinforced concrete (PC) continuous girder bridge with laminated rubber bearings (LRBs), a two-linked continuous bridge was used as the background to consider the effect of extreme temperature on the properties of LRBs and pier concrete. First, the properties of concrete specimens were tested at different temperatures to obtain their mechanical parameters at extreme temperatures. Then, we obtained the effect of extreme temperature on the seismic response of consecutive bridges with LRBs by examining the seismic response of the pier moments, pier top displacements, and bearing deformations. The results show that compared with normal temperatures, the extreme temperature causes a change in parameters of the LRBs and concrete pier, which increases the internal force and displacement response of a pier under an extremely low temperature by 37.13% and 32.74%, respectively. The displacement of bearings under extremely high temperature conditions increases by 16.31%. The influence of temperature changes on the mechanical parameters of LRBs will change the connection stiffness of the pier and superstructure, resulting in significant changes in the seismic response of the pier and bearing, so that the internal force and displacement response of the pier are negatively correlated with the temperature.
To better understand the mechanical property issues of in-service concrete-filled steel tube (CFST) bridges susceptible to natural environmental temperatures, 13 CFST stub columns were assessed under axial compression with different ambient temperatures and steel ratios, with the strength of the core concrete as the main parameters. The influence of ambient temperature on the peak strain and joint elastic modulus of the CFST stubs was investigated. The influence mechanism of steel content and core concrete strength on the residual toughness of the CFST at different ambient temperatures was revealed. In this study, we proposed a modified constitutive equation for CFST, taking into account the ambient temperature. We demonstrated that the peak strain, residual toughness ratio, and elastic modulus of the CFST stubs significantly decreased when the temperature decreased. The calculated values of the modified constitutive equation for CFST, taking into account the ambient temperature, were in good agreement with the test results and could be used to predict the trends in stress properties of the CFST stubs at different temperatures. The results could serve as a critical reference for the design and calculation of CFST structures in very cold regions.