Phitsini Suvarnaphaet

Dr. Phitsini Suvarnaphaet


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
PSPhitsini Suvarnaphaet
Phitsini Suvarnaphaet
SPSuejit Pechprasarn
Suejit Pechprasarn
The advantages conferred by the physical, optical and electrochemical properties of graphene-based nanomaterials have contributed to the current variety of ultrasensitive and selective biosensor devices. In this review, we present the points of view on the intrinsic properties of graphene and its surface engineering concerned with the transduction mechanisms in biosensing applications. We explain practical synthesis techniques along with prospective properties of the graphene-based materials, which include the pristine graphene and functionalized graphene (i.e., graphene oxide (GO), reduced graphene oxide (RGO) and graphene quantum dot (GQD). The biosensing mechanisms based on the utilization of the charge interactions with biomolecules and/or nanoparticle interactions and sensing platforms are also discussed, and the importance of surface functionalization in recent up-to-date biosensors for biological and medical applications.

1 December 2016 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
PSPhitsini Suvarnaphaet
Phitsini Suvarnaphaet
CTChandra Sekhar Tiwary
Chandra Sekhar Tiwary
JWJutaphet Wetcharungsri
Jutaphet Wetcharungsri
SPSupanit Porntheeraphat
Supanit Porntheeraphat
RHRassmidara Hoonsawat
Rassmidara Hoonsawat
PAPiyapong Asanithi
Piyapong Asanithi

22 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
PSPhitsini Suvarnaphaet
Phitsini Suvarnaphaet
SPSuejit Pechprasarn
Suejit Pechprasarn
In this paper, we report a theoretical framework on the effect of multiple resonances inside the dielectric cavity of insulator-insulator-metal-insulator (IIMI)-based surface plasmon sensors. It has been very well established that the structure can support both long-range surface plasmon polaritons (LRSPP) and short-range surface plasmon polaritons (SRSPP). We found that the dielectric resonant cavity under certain conditions can be employed as a resonator to enhance the LRSPP properties. These conditions are: (1) the refractive index of the resonant cavity was greater than the refractive index of the sample layer and (2) when light propagated in the resonant cavity and was evanescent in the sample layer. We showed through the analytical calculation using Fresnel equations and rigorous coupled wave theory that the proposed structure with the mentioned conditions can extend the dynamic range of LRSPP excitation and enhance at least five times more plasmon intensity on the surface of the metal compared to the surface plasmon excited by the conventional Kretschmann configuration. It can enhance the dip sensitivity and the dynamic range in refractive index sensing without losing the sharpness of the LRSPP dip. We also showed that the interferometric modes in the cavity can be insensitive to the surface plasmon modes. This allowed a self-referenced surface plasmon resonance structure, in which the interferometric mode measured changes in the sensor structure and the enhanced LRSPP measured changes in the sample channel.

17 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
PSPhitsini Suvarnaphaet
Phitsini Suvarnaphaet
SPSuejit Pechprasarn
Suejit Pechprasarn
Surface plasmon Resonance (SPR) has recently been of interest for label-free voltage sensing. Several SPR structures have been proposed. However, making a quantitative cross-platform comparison for these structures is not straightforward due to (1) different SPR measurement mechanisms; (2) different electrolytic solution and concentration in the measurement; and (3) different levels of external applied potential. Here, we propose a quantitative approach to make a direct quantitative comparison across different SPR structures, different electrolytic solutions and different SPR measurement mechanisms. There are two structures employed as example in this theoretical study including uniform plasmonic gold sensor and bimetallic layered structure consisting of uniform silver layer (Ag) coated by uniform gold layer (Ag). The cross-platform comparison was carried by several performance parameters including sensitivity (S), full width half maximum (FWHM) and figure of merit (FoM). We also discuss how the SPR measurement mechanisms enhance the performance parameters and how the bimetallic layer can be employed to enhance the FoM by a factor of 1.34 to 25 depending on the SPR detection mechanism.

1 November 2019
Verified
Conference Paper
Closed access
PSPhitsini Suvarnaphaet
Phitsini Suvarnaphaet
SSSuvicha Sasivimolkul
Suvicha Sasivimolkul
CSChayanisa Sukkasem
Chayanisa Sukkasem
DPDanai Pukesamsombut
Danai Pukesamsombut
Nuttapol TanadchangsaengNuttapol Tanadchangsaeng
Nuttapol Tanadchangsaeng
SPSuejit Pechprasarn
Suejit Pechprasarn
A biomedical electrode patch for detecting an electrocardiogram signal which is provoked by electrical activity through the heart has been investigated. The electrode patch was made of chemical derived graphene as an electrically conductive layer and polyhydroxyalkanoate (PHA) as a flexible substrate. This gra-phene/PHA patch has been promised to be completely biocom-patible and biodegradable by microbes in terrestrial environments. According to the fabrication of the electrode patch, gra-phene was synthesized using Hummers’ method and reduction with hydrazine hydrate. The PHA membrane, an aliphatic polyester bioplastic, was accumulated by Ralstonia eutropha and then was casted using electrospinning technique to serve nanofiber scaffold for an abundance of graphene to be addressed. The gra-phene/PHA electrodes were interfaced to 3-lead electrocardiogram (ECG) sensor and amplifier modules controlling by computing microcontroller. Real-time in vitro monitoring of the simulated ECG signals were observed, including normal condition at 60 BPM and abnormal heart rhythms, through the interfaces of graphene/PHA electrodes. The signals have been shown obviously and no degradation over time, however, the signal attenuation might increase due to in vivo measurement of human skin-electrode impedance.

21 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SPSuejit Pechprasarn
Suejit Pechprasarn
SSSuvicha Sasivimolkul
Suvicha Sasivimolkul
PSPhitsini Suvarnaphaet
Phitsini Suvarnaphaet
We have recently reported in our previous work that one-dimensional dielectric grating can provide an open structure for Fabry–Perot mode excitation. The grating gaps allow the sample refractive index to fill up the grating spaces enabling the sample to perturb the Fabry–Perot mode resonant condition. Thus, the grating structure can be utilized as a refractive index sensor and provides convenient sample access from the open end of the grating with an enhanced figure of merit compared to the other thin-film technologies. Here, we demonstrate that 2D grating structures, such as rectangular pillars and circular pillars, can further enhance refractive index sensing performance. The refractive index theory for rectangular pillars and circular pillars are proposed and validated with rigorous coupled wave theory. An effective refractive index theory is proposed to simplify the 2D grating computation and accurately predict the Fabry–Perot mode positions. The 2D gratings have more grating space leading to a higher resonant condition perturbation and sensitivity. They also provide narrower Fabry–Perot mode reflectance dips leading to a 4.5 times figure of merit enhancement than the Fabry–Perot modes excited in the 1D grating. The performance comparison for thin-film technologies for refractive index sensing is also presented and discussed.