Reza Fazel-Rezai

Dr. Reza Fazel-Rezai


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Frontiers in Neuroengineering
Verified
Journal Article
Open access
RFReza Fazel-Rezai
Reza Fazel-Rezai
BABrendan Z. Allison
Brendan Z. Allison
CGChristoph Guger
Christoph Guger
ESEric W. Sellers
Eric W. Sellers
SKSonja C. Kleih
Sonja C. Kleih
AKAndrea Kübler
Andrea Kübler
A brain-computer interface (BCI) enables communication without movement based on brain signals measured with electroencephalography (EEG). BCIs usually rely on one of three types of signals: the P300 and other components of the event-related potential (ERP), steady state visual evoked potential (SSVEP), or event related desynchronization (ERD). Although P300 BCIs were introduced over twenty years ago, the past few years have seen a strong increase in P300 BCI research. This closed-loop BCI approach relies on the P300 and other components of the ERP, based on an oddball paradigm presented to the subject. In this paper, we overview the current status of P300 BCI technology, and then discuss new directions: paradigms for eliciting P300s; signal processing methods; applications; and hybrid BCIs. We conclude that P300 BCIs are quite promising, as several emerging directions have not yet been fully explored and could lead to improvements in bit rate, reliability, usability, and flexibility.

25 February 2013 in Advances in Human-Computer Interaction
Verified
Journal Article
Open access
PDF file
SASetare Amiri
Setare Amiri
RFReza Fazel-Rezai
Reza Fazel-Rezai
VAVahid Asadpour
Vahid Asadpour
Increasing number of research activities and different types of studies in brain-computer interface (BCI) systems show potential in this young research area. Research teams have studied features of different data acquisition techniques, brain activity patterns, feature extraction techniques, methods of classifications, and many other aspects of a BCI system. However, conventional BCIs have not become totally applicable, due to the lack of high accuracy, reliability, low information transfer rate, and user acceptability. A new approach to create a more reliable BCI that takes advantage of each system is to combine two or more BCI systems with different brain activity patterns or different input signal sources. This type of BCI, called hybrid BCI, may reduce disadvantages of each conventional BCI system. In addition, hybrid BCIs may create more applications and possibly increase the accuracy and the information transfer rate. However, the type of BCIs and their combinations should be considered carefully. In this paper, after introducing several types of BCIs and their combinations, we review and discuss hybrid BCIs, different possibilities to combine them, and their advantages and disadvantages.

1 January 2012 in Computational Intelligence and Neuroscience
Verified
Journal Article
Open access
PDF file
ARAhmed Fazle Rabbi
Ahmed Fazle Rabbi
RFReza Fazel-Rezai
Reza Fazel-Rezai
We present a multistage fuzzy rule-based algorithm for epileptic seizure onset detection. Amplitude, frequency, and entropy-based features were extracted from intracranial electroencephalogram (iEEG) recordings and considered as the inputs for a fuzzy system. These features extracted from multichannel iEEG signals were combined using fuzzy algorithms both in feature domain and in spatial domain. Fuzzy rules were derived based on experts' knowledge and reasoning. An adaptive fuzzy subsystem was used for combining characteristics features extracted from iEEG. For the spatial combination, three channels from epileptogenic zone and one from remote zone were considered into another fuzzy subsystem. Finally, a threshold procedure was applied to the fuzzy output derived from the final fuzzy subsystem. The method was evaluated on iEEG datasets selected from Freiburg Seizure Prediction EEG (FSPEEG) database. A total of 112.45 hours of intracranial EEG recordings was selected from 20 patients having 56 seizures was used for the system performance evaluation. The overall sensitivity of 95.8% with false detection rate of 0.26 per hour and average detection latency of 15.8 seconds was achieved.

31 May 2013 in Applied Soft Computing
Verified
Journal Article
Closed access
MVMaryam Vatankhah
Maryam Vatankhah
VAVahid Asadpour
Vahid Asadpour
RFReza Fazel-Rezai
Reza Fazel-Rezai

26 September 2012 in Biomedical Engineering Letters
Verified
Journal Article
Closed access
PDF file
ARAhmed Fazle Rabbi
Ahmed Fazle Rabbi
AZAbongwa Zony
Abongwa Zony
PLPablo de Leon
Pablo de Leon
RFReza Fazel-Rezai
Reza Fazel-Rezai

8 August 2016
Verified
Conference Paper
Closed access
NANasim Alamdari
Nasim Alamdari
AHAli Haider
Ali Haider
RARiadh Arefin
Riadh Arefin
AVAjay K. Verma
Ajay K. Verma
KTKouhyar Tavakolian
Kouhyar Tavakolian
RFReza Fazel-Rezai
Reza Fazel-Rezai
Brain-computer interface (BCI) systems provide a device for communication that does not depend on the brain's normal output and peripheral nerves. Recently, BCIs have attracted massive attention, triggered by new scientific progress in understanding brain function and by impressive applications. This paper will study steps in the regular BCI system, various BCI systems, methods used in processing signals, applications, improvements, and current challenges. Finally, BCI possible future trends are discussed.