Renewable energy source-fed heat pumps (HPs) may perform up to very high-efficiency standards, offering a promising tool in the wider residential heat decarbonization effort. In this context, this paper investigates different heating configurations utilizing various renewable thermal sources in conjunction with an HP-based system in order to determine the optimal configuration in terms of efficiency, using an existing, fully functioning residential building in Zaragoza, Spain, as our case study, comprising 40 dwellings. Four different HP configurations are investigated:, (i) an air-source system, (ii) a ground-source system, (iii) a dual-source system with solar thermal collectors, and (iv) a triple-source system based on solar, geothermal, and ambient sources. For the purpose of such investigation, detailed dynamic energy simulations are conducted through the use of the INTEMA.building tool (developed in Modelica), applying a multi-objective optimization process that aims at minimizing both the annual electricity consumption and the net present cost. It is demonstrated that the renewable thermally driven HPs are more efficient than the conventional, air-source ones, with the seasonal coefficient of performance increasing by 9.98% (ground source), 4.57% (dual source), and 17.40% (triple source), compared to the air-source heat pump system. Finally, it is revealed (via integrated techno-economic analyses) that the most effective and economical design is the dual source system, while the most expensive is the ground-source configuration. These findings can guide the ongoing design efforts on green residential heat solutions at both research and commercial implementation level.
This study investigates the deployment of VERIFY, a dynamic life cycle assessment (LCA) and life cycle costing (LCC) tool, tailored to evaluate the energy and environmental performance of building renovation strategies. The tool was applied to three diverse building renovation projects across Europe, offering insights into how life cycle-based tools can enhance decision-making by integrating operational data and modeling of energy systems. The paper highlights how VERIFY captures both embodied and operational impacts—addressing limitations of conventional energy assessments—and aligns with EU frameworks such as Level(s). Key findings from the case studies in Italy, Spain, and the Netherlands demonstrate how LCA/LCC-based approaches can support energy efficiency objectives and guide sustainability-aligned renovation investments. Across the three case studies, the tool demonstrated up to 51% reduction in primary energy demand, 66% decrease in life cycle greenhouse gas emissions, and 51% reduction in life cycle costs. These outcomes provide researchers with a validated dynamic LCA/LCC framework and offer practitioners a replicable methodology for planning and evaluating sustainability-driven renovations. Despite their advantages, the effective use of LCA tools in energy renovation faces challenges, including limited data availability, regulatory fragmentation, and methodological complexity. The paper concludes that advanced tools such as VERIFY, when harmonized with evolving EU energy performance and sustainability standards, can strengthen the evidence base for deep energy renovation and carbon reduction in the building sector.
This study aims to assist in the identification of suitable key performance indicators (KPIs) that can be used to assess the sustainability performance of buildings given their transition into zero-carbon, resource-efficient, and resilient structures. To that end, a four-step methodology is proposed in this work; the first step includes the development of a KPI repository, which builds upon commonly accepted targets derived from the needs of different stakeholders as well as targets imposed by external factors. The second step refers to the expansion of the initial KPI repository, capitalizing on information from the literature. The third step includes the refinement of the repository based on predefined criteria (relevance, availability, measurability, reliability, and familiarity) and tailored feedback from key stakeholders. The final step concerns the development of KPI cards, which include all the necessary information for understanding and estimating the KPIs included in the final repository. This four-step methodological approach implementation was tested during the EU-funded HORIZON project ‘InCUBE’. The implementation of the first two steps of the proposed methodology resulted in a pool of 68 KPIs. Nearly half of these KPIs were extracted from Step 1 to fully support the monitoring of all InCUBE outcomes, while the rest of the KPIs were extracted from highly relevant Horizon frameworks, the B4P partnership, Level(S) framework, publications, and ETSI standards (Step 2). The implementation of Step 3 resulted in a shortlisted KPI pool which eventually defined the final InCUBE KPI repository, including 31 KPIs. To help with the coordination of the data gathering process and a shared understanding of the sort of information to be monitored among various stakeholders, selected KPI cards (Step 4) are presented.